Brooklyn · Block 5081 · Lot 52 · 11226

499 Ocean Avenue

7 floors · 48 apartments · 33,600 sq ft · built 1931 · class D1 · owner of record: Reb Yukateal Realty Llc

26open violations
$4,062ECB/OATH penalties owed
7HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 33,600 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 431 days
Next cycle year 2027
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $290,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 849 days
Filing window not open yet
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-05 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $4,062 owed
IssuedViolationHearingBalance
Jul 23, 2026Elevators CLASS - 1
CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR (2.14.5.7.1.). CLASS 2 ITEMS : REPLACE OR SECURE WORN GIBS WHERE NEEDED (2.11.11.5.7.). DEFECTIVE CAR PHONE (2.27.1.1.3.). WORN CAB MIRROR (BC 3001.6). EXPIRED B
#39197325N
Dec 2, 2026
$1,250
Jun 1, 2026Elevators CLASS - 1
ASME 17.1 2.14.5.7.1 CEASE USE DOOR ZONE RESTRICTOR DISABLED, 5.1.21.1 EMERGENCY SIGNAL CAR PHONE INOPERATIVE.
#39190548Z
Mar 30, 2027
$1,250
Feb 23, 2024Elevators CLASS - 2
REPAIR IN-CAR EMERGENCY PHONE., REPLACE COUNTER-WEIGNT SHACKEL TENSION SPRINGS (BROKEN)., REPAIR UNDER CAR LIGHT., REPAIR TOP OF CAR LIGHT., PROVIDE IN-CASE OF FIRE SIGN WHERE MISSING., ADJUST OR REPLACE CAR DO
#39106728L
Mar 16, 2027
$1,562
Jan 26, 2015Local Law CLASS - 2
FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28-302 & THE DEPT OF BLDGS RULES & REGULAT
#36027169J
Nov 25, 2015
IN VIOLATION
$0
DOB (6)
IssuedViolationStatus
Dec 1, 2022FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2201365
DOB VIOLATION - ACTIVE
Aug 13, 2021ELEVATOR

#9028/707519
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2003588
DOB VIOLATION - ACTIVE
Dec 31, 2013NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
#01041
DOB VIOLATION - ACTIVE
Apr 12, 2012CONSTRUCTION

#1404RH
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#03259
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Dec 1, 2022Energy Grade - LL33 FTP-EN-EGRDEA
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Apr 30, 2019Facades FISPNRF
FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019
Active
Dec 31, 2013Facades FISPNRF
FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013
Active
HPD (14) · C 7 · B 5 · A 2
IssuedClassViolationCorrect by
Sep 11, 2026A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER SHOE TACK WELDED, SECURE WITH PROPER NUTS AND BOLTS AT 1ST FIRE ESCAPE FROM (NORTH) AT (EAST) BUILDING FRONT AT FIRE ESCAPEDec 15, 2026
Mar 12, 2026BApt 5B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE BATHROOM LOCATED AT APT 5B, 6th STORY, 1st APARTMENT FROM NORTH AT EASTApr 16, 2026
Jan 29, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED AT 1ST STORY AT PUBLIC HALL, 1st STORYFeb 4, 2026
Jan 29, 2026CApt 2B · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJan 29, 2026
Nov 8, 2024CApt 6C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 8, 2024
Mar 15, 2024BApt 5B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 6SQ FT AT NORTH EAST CORNER NEAR THE FLOOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16379259 ISSUED 14-NOV-23 HAS BEEN UPGRADED TO CApr 19, 2024
Mar 4, 2024BApt 6F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTApr 8, 2024
Mar 4, 2024BApt 6F · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTApr 8, 2024
Nov 16, 2023CApt 5B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EASTDec 12, 2023
Nov 16, 2023CApt 5B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM NORTH AT EASTDec 12, 2023
Mar 2, 2023CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTMar 28, 2023
Mar 10, 2022BApt 1B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT WALLS, (20 SQ. FT.) IN THE BATHROOM LOCATED AT APT 1B, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTApr 14, 2022
Dec 20, 2021AApt 6D · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE METAL RADIATOR COVER AT NORTH WALL IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTMar 25, 2022
Dec 20, 2021CApt 6D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTJan 15, 2022

Issued in the last 120 days

DateSourceWhatNow
Sep 11, 2026HPD A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER SHOE TACK WELDED, SECURE WITH PROPER NUTS AND BOLTS AT 1ST FIRE ESCAPE FROM (NORTH) AT (EAST) BUILDING FRONT AT FIRE ESCAPEOpen
Jul 23, 2026ECBElevators: CEASE USE ITEM: INOPERATIVE ZONE LOCK RESTRICTOR (2.14.5.7.1.). CLASS 2 ITEMS : REPLACE OR SECURE WORN GIBS WHERE NEEDED (2.11.11.5.7.). DEFECTIVE CAR PHONE (2.27.1.1.3.). WORN CAB MIRROR (BC 3001.6). EXPIRED BClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:42 PM ET. BBL 3050810052.