Bronx · Block 2261 · Lot 3 · 10454

496 East 134th Street

1 floors · 3,343 sq ft · built 1963 · class E9 · owner of record: 134th St Venture Partners Llc

0open violations
$10,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
775dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 775 days
Next cycle year 2028

Open violations

ECB / OATH (4) · $10,000 owed
IssuedViolationHearingBalance
Mar 4, 2026Construction CLASS - 1
DURING MY INSPECTION OF AN ACTIVE 5-STORY NB AT THE SOE PHASE. I OBSERVED A MISSING SHORING SYSTEM AT EXPOSURE 3, REAR CORNER OF 2, AND AN INADEQUATE 45-DEGREE ANGLE OF REPOSE AT EXPOSURE 2, WITH WORKERS CONSTR
#39551222J
Jan 5, 2027
$2,500
Mar 4, 2026Unknown CLASS - 2
DURING MY INSPECTION OF AN ACTIVE SITE WITH ONGOING SOE AND FOUNDATION WORK IN PROGRESS. I OBSERVED THE EXISTING STRUCTURE BEING UTILIZED TO SUPPORT THE EXCAVATION EXPOSURES 3 & 4. BC 1817.3 NO EVALUATION OF AD
#39551223L
Jan 5, 2027
$2,500
Feb 27, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A, ACTIVE JOBSITE AT EXCAVATION PHASE, I OBSERVED PEDESTRIANS WALKWAY BLOCK WITH BARRIERS AND NOT MAINTAIN 5-FT WALKWAY AS PER BC 3307.2.6 ALSO THERE WAS NO WARN SIGNAGE IN PLACE AN
#39551038J
Jan 5, 2027
$2,500
Feb 27, 2026Site Safety CLASS - 1
AT THE TIME OF INSPECTION, ACTIVE JOBSITE AT EXCAVATION PHASE UPON REQUESTING PRE CONSTRUCTION SURVEY, VIBRATING MONITORING, AND OPTICAL MONITORING CONSTRUCTION DOCUMENT NON WAS MADE AVAILABLE AS REQUIRE, CREAT
#39551028X
Jan 5, 2027
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 2:33 PM ET. BBL 2022610003.