4 floors · 26 apartments · 42,000 sq ft · built 1930 · class C7 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 49 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 49 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 49 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 65 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 42,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 170 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 170 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-06 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 24, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSEWRVED HOLE PENETRATIONS THROUGHOUT BASEMENT. POTENTIAL HAZARD., REPAIR AND/REPLACE #39193563K | Jul 9, 2026 POP/IN-VIO | $0 |
| Jun 24, 2026 | Boilers CLASS - 2 FOUND AO SMITH HW-520 HOT WATER BOILER NOT REGISTERED AND LEAKING PRESSURE RELIEF VALVE ON HEATING BOILER., MAINTAIN BOILER #39193570Z | Jul 9, 2026 POP/IN-VIO | $0 |
| Jun 24, 2026 | Unknown CLASS - 2 FAILURE TO POST AND DISTRIBUTE NOTICE TO OCCUPANTS OF TPP. OBSERVED NO TTP ON FILE AND NO TPP POSTED., POST/DISTR. NOTICE #39193564M | Jul 9, 2026 POP/IN-VIO | $0 |
| Oct 30, 2023 | Construction CLASS - 2 MAJOR SIGNS OF WATER PENETRATION IN BOTH (A & B) BULKHEADS AND THROUGHOUT BUILDING., REPAIR AND/OR REPLACE #39098305M | Nov 14, 2023 POP/IN-VIO | $0 |
| Oct 30, 2023 | Construction CLASS - 2 OBSERVED NO FRESH AIR VENTILATION IN THE BOILER ROOM. AS PER FGC 304.4.2 PROVISIONS MUST BE MADE FOR PROPER AIR BALANCE TO PREVENT A NEGATIVE OR POSITIVE PRESSURE IN THE BOILER ROOM AND TO DISCHARGE THE VENTILA #39098256P | Nov 15, 2023 POP/IN-VIO | $0 |
| Mar 15, 2022 | Construction CLASS - 2 I DID NOT OBSERVE A FRESH AIR INTAKE VENT IN THE BOILER ROOM ALSO I DID NOT OBSERVE AND FRESH ARE VENTILATION THE THE GAS METER ROOM., REPAIR AND/OR REPLACE #39058208Y | Mar 29, 2022 POP/IN-VIO | $0 |
| Mar 15, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.OBSERVED AT CELLAR LEVEL STAIRCASE HAVE BECOME POROUS ALLOWING WATER TO PENETRATE THROUGH THE WALLS SHOWING SIGNS OF PAINT,CEILING AND WALL DAMAGES.REMEDY:R #35651049H | Aug 17, 2022 POP/IN-VIO | $0 |
| Nov 17, 2021 | Construction CLASS - 2 NOTED: SPALLING PLASTER AT BOTH EAST AND WEST BULKHEADS, WEST BULKHEAD HAS LOOSE WALL TILES ON THE VERGE OF DETACHING., REPAIR AND/OR REPLACE #39051397K | Dec 14, 2021 POP/IN-VIO | $0 |
| Nov 17, 2021 | Construction CLASS - 2 I OBSERVED NO VENTILATION IN THE GAS METER ROOM ALSO I DID NOT OBSERVE THE FRESH AIR IN TAKE FOR THE BOILER ROOM., REPAIR AND/OR REPLACE #39051496X | Dec 13, 2021 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 16) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 3, 2014 | C | Apt 2L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 31, 2014 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)