Manhattan · Block 2180 · Lot 7 · 10033

482 Ft Washington Avenue

6 floors · 48 apartments · 51,138 sq ft · built 1930 · class D1 · owner of record: 482 Ft. Washington Llc

9open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
59dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 59 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 59 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 75 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 51,138 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 180 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 180 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 303 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 424 days
Next cycle year 2027
Energy audit and retro-commissioning (2030) Likely applies
Local Law 87 · Calendar year 2030
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2180). Agency page

Dec 31, 2030
in 1520 days
Next due 2030
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-09 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Apr 5, 2018Construction CLASS - 2
FAILURE TO PROVIDE SIDEWALK SHED PARAPET SIGN ACCORDING TO 3301.9.2. NOTED: AT TIME OF INSPECTION SIDEWALK SHED MISSING PARAPET SIGN ACCORDING TO 3301.9.2. NOTED: AT TIME OF INSPECTION SIDEWALK SHED MISSING PAR
#35323700P
May 24, 2018
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Apr 2, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING EXTERIOR WALL AND APPURTANCES IN CODE COMPLAINT MANNER. NOTE: AT TIME OF INSPECTION OBBSERVED SHATTERED BROKEN GLASS PANE OF 7TH FL OF SW CORNER AT EXPOSURE #1 WEST ELEVATION REMEDY: OWNER TO REPAIR AND/OR REPLACE BROKEN GLASS
#SR11205YC
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (7) · C 2 · B 4 · A 1
IssuedClassViolationCorrect by
Oct 29, 2026CApt 6D · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 29, 2026
Oct 29, 2026BApt 6D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL AND CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTDec 3, 2026
Oct 29, 2026AApt 6D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET OBSERVED AT CEILING IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTFeb 1, 2027
Oct 29, 2026BApt 6D · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLETS AT THE WEST WALL IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTDec 3, 2026
Oct 29, 2026C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOMNov 4, 2026
Aug 19, 2026BApt 4A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EASTSep 23, 2026
Aug 19, 2026BApt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EASTSep 23, 2026

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Oct 29, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST WALL AND CEILING IN THE 5th ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Oct 29, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FEET OBSERVED AT CEILING IN THE BATHROOM LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Oct 29, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLETS AT THE WEST WALL IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Oct 29, 2026HPD C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOMOpen
Aug 19, 2026HPD C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING -KICK DOWN STOPPER INSTALLED AT VESTIBULE DOOR , 1st STORYClosed
Aug 19, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 19, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4A, 4th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 8:39 PM ET. BBL 1021800007.

Look up another building