Brooklyn · Block 776 · Lot 40 · 11220

4812 7 Avenue

3 floors · 4 apartments · 7,410 sq ft · built 1919 · class O8 · owner of record: Sixland Holding Group Inc.

0open violations
$80,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (7 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-01 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 7 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 310 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029

Open violations

ECB / OATH (13) · $80,000 owed
IssuedViolationHearingBalance
Mar 23, 2021Construction CLASS - 2
FAILURE OF PERMIT HOLDER TO PROVIDE INSPECTION ACCESS TO &/OR EXPOSE ONGOING CONSTRUCTION WORK ON AN ACTIVE & PERMITTED WORKSITE. NOTE: OBSERVED 4 WORKERSS,CMU OPERATIONS AT REAR YARD EXP#3 FROM PUBLIC SIDEWALK
#35496776R
Oct 1, 2021
DEFAULT
$5,000
Mar 23, 2021Site Safety CLASS - 1
UNLAWFUL ACTS,FAILURE TO COMPLY W/A COMMISSIONERS ORDER INVOLDING CONSRUCTION OPERATIONS. NOTE: AT TIME OF INSPECTION OBSERVED 4 WORKERS AT REAR YARD OF EXP#3 CMU OPERATIONS IN PROGRESS. AFTER ANNOUNING MYSELF
#35496777Z
Oct 1, 2021
DEFAULT
$12,500
Jan 27, 2021Construction CLASS - 1
NO HANDRAILS. NOTE: AT THE TIME OF INSPECTION AT ACTIVE CONSTRUCTION SITE,I OBSERVED THAT THERE WERE NO HANDRAILS IN PLACE AT STAIRS FROM 1ST FL TO THE CELLAR LEVEL & FROM 1ST FL TO 2ND FL. FAILURE TO PROVIDE &
#35508710J
Aug 8, 2022
DEFAULT
$6,250
Jan 27, 2021Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTE: AT THE TIME OF INSPECTION OF 3 STY ALT-1 WORK JOB SITE WAS ACTIVE. I OBSERVED FOUNDATION/EXCAVATION WORK AT REAR YARD AT EX
#35508706R
Jun 9, 2021
DEFAULT
$12,500
Oct 21, 2020Unknown CLASS - 2
FAILURE TO POST OR DISTRIBUTE "SAFE CONSTRUCTION BILL OF RIGHTS". NOTED:AT TIME OF INSPECTION AT AN ACTIVE JOBSITE,OBSERVED APT#2R AND 3R OCCUPIED AND NO SCBOFR POSTED. REMEDY:POST OR DISTRIBUTE SAFE CONST BILL
#35539700H
Mar 3, 2021
DEFAULT
$3,125
Oct 21, 2020Construction CLASS - 2
BC 3309.1 PROTECT ADJOINING PROPERTY. NOTED:AT TIME OF INSPECTION AT AN ACTIVE JOBSITE. OBSERVED AT EXP#2 OF THE ADJOINING PROPERTY COURTYARD NOT FULLY PROTECTED. REMEDY:COMPLY W/ CODE CONTACT CSE FOR RE INSPEC
#35539347X
Mar 3, 2021
DEFAULT
$3,125
Oct 21, 2020Construction CLASS - 2
BC 3301.2 MISSING REBA CAPS. NOTED: AT TIME OF INSPECTION AT AN ACTIVEJOBSITE. OBSERVED AT EXP #2 COURTYARD AREA REBA MISS CAPS. REMEDY: COMPLY WITH CODE
#35539348H
Mar 3, 2021
DEFAULT
$3,125
Oct 21, 2020Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED PLAN. NOTED:AT TIME OF INSPECTION ATAN ACTIVE JOBSITE. UPON REVIEWING STRUCTURAL PLAN SECTION S-101.01 SHOW W 14X22 (STRAIGHT)ACROSS FROM WALL TO WALL. HOWEVER OBSERVED STEEL C
#35539342R
Mar 3, 2021
DEFAULT
$6,250
Oct 21, 2020Construction CLASS - 1
BC 3305.2.2 STEEL FABRICATION ON SITE/FIELD CONNECTION. NOTED:AT TIME OF INSPECTION OF AN ACTIVE JOBSITE. OBSERVED STEEL HAD BEEN MODIFIED,CUT AND WELDED,UPON REQUEST FOR PE DESIGN DRAWING NONE WAS AVAILABLE/PR
#35539343Z
Mar 3, 2021
DEFAULT
$6,250
Oct 21, 2020Unknown CLASS - 2
FAILURE TO POST AND DISTRIBUTE NOTICE TO OCCUPANTS OF TPP. NOTED:AT TIME OF INSPECTION AT AN ACTIVE JOBSITE. UPON REVIEWING DOB BIS APPLICATION OBSERVED BUILDING TO REMAIN OCCUPIED AND 2R AND 3R OCCUPIED AND NO
#35539349J
Mar 3, 2021
DEFAULT
$3,125
Oct 21, 2020Unknown CLASS - 1
PERMIT HOLDER FAILED TO ENSURE THAT EACH CONSTRUCTION OR DEMOLITION WORKER WORKING/ENGAGED AT THE SITE SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC 3321.1 AND HAS AN OSHA 30 ISSUED IN THE LAST 5 YEARS,
#35539701J
Mar 3, 2021
DEFAULT
$12,500
Oct 21, 2020Construction CLASS - 2
FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. NOTED:AT TIME OF INSPECITON AT AN ACTIVE JOBSITE. UPON REQUEST TO SEE THE TOOLS BOX TALK NONE WAS PROVIDED AND THE SITE SPECIFIC ORIENTAT
#35539346Y
Mar 3, 2021
DEFAULT
$3,125
Oct 21, 2020Construction CLASS - 2
28-110.1 INADEQUATE SITE SAFETY PLAN. NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE UPON REVIEWING THE SITE SAFETY PLANS OBSERVED IT WASNOT SIGN AND DATED BY THE PREPARER. REMEDY: PROVIDE ADEQUATE SSP
#35539345M
Mar 3, 2021
DEFAULT
$3,125
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 5:00 PM ET. BBL 3007760040.