Manhattan · Block 838 · Lot 76 · 10018

48 West 37 Street

18 floors · 130,625 sq ft · built 1926 · class O6 · owner of record: 48 W 37 Associates Llc

14open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
168dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 130,625 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Energy audit and retro-commissioning (2028) Likely applies
Local Law 87 · Calendar year 2028
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 838). Agency page

Dec 31, 2028
in 778 days
Next due 2028
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-13 (Accepted). Agency page

On file2026 reports accepted
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $21,000 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2026-10-09)

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Mar 10, 2014Construction CLASS - 2
FAILURE TO SAFEGUARD NOTED AT TIME OF INSPECTION SIDEWALK SHED LOADED WITH MATERIAL,PLYWOOD,25 SAND BAGS,DEBRI,BRICK.SIDEWALK SHED PERMIT DOES NOT STATE RATED FOR MATERIAL STORAGE. WALKWAY IS HEAVY PEDESTRIAN V
#35088977K
Apr 24, 2014
IN VIOLATION
$0
DOB (10)
IssuedViolationStatus
Aug 15, 2023CONSTRUCTION
EMERGENCY WORK ORDER DUE TO HAZARDOUS CONDITION ON EXPOSURE#1 NORTH ELEVATION SHED MUST BE INSTALL ALONG THE FULL LENGTH OF EXPOSURE#1 WITH 20"FT. BEYOND BOUNDARY INE ON EACH SIDE TO PROTECT WITH 2O FT BEYOND BOUNDARY LINE ON EACH SIDE TO PROTECT PUB.SPALLING TERRA COTTA WORK OBSERV.& DEFECT.REMEDY:
#LL0501RF
DOB VIOLATION - ACTIVE
Sep 3, 2019SPRINKLER
FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
#NRF00144
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#01517
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#01518
DOB VIOLATION - ACTIVE
Oct 15, 2002ELEVATOR

#1P15533
DOB VIOLATION - ACTIVE
Oct 15, 2002ELEVATOR

#1P15530
DOB VIOLATION - ACTIVE
Oct 15, 2002ELEVATOR

#1P15531
DOB VIOLATION - ACTIVE
Oct 15, 2002ELEVATOR

#1P15532
DOB VIOLATION - ACTIVE
Jun 5, 1997CONSTRUCTION

#B5GG03
VIOLATION UNSERVED ECB-ACTIVE
Jun 5, 1997CONSTRUCTION

#GG03
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Sep 3, 2019Sprinklers FTF-SP-FINAL
Active
Jan 26, 2018Elevators ACC1
Active
Jan 26, 2018Elevators ACC1
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:51 AM ET. BBL 1008380076.

Look up another building