Bronx · Block 2307 · Lot 46 · 10455

477 Willis Avenue

1 floors · 8,025 sq ft · built 1965 · class O1 · owner of record: 477 Willis Ave Ii Llc

10open violations
$45,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
799dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 799 days
Next cycle year 2028

Open violations

ECB / OATH (10) · $45,000 owed
IssuedViolationHearingBalance
Sep 8, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, I OBSERVED ADJACENT PROPERTIES EXPOSURE#2-4 WITHIN 20FT OF THE CONSTRUCTION SITE, WINDOW WERE NOT PROPERLY COVER OR PROTECTED FROM FALLING AND FLYING DEBRIS,
#39558929P
Nov 20, 2026
PENDING
$2,500
Sep 8, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE CONSTRUCTION WAS IN PROGRESS, AT THE 2ND-FLOOR DECK, MULTIPLE SECTIONS OF THE OPEN PERIMETER AND LEADING EDGES LACKED REQUIRED GUARDRAILS, EX
#39558919L
Nov 20, 2026
PENDING
$5,000
Sep 8, 2026Site Safety CLASS - 1
AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSE, UPON REQUEST SITE SAFETY PLAN, STRUCTURAL PLAN, PRE SHIFT MEETING, AND APPROVED DESIGN DRAWING FO
#39558917H
Nov 20, 2026
PENDING
$2,500
Sep 8, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSED WITH MATERIALS ON 2-WORKERS ON THE FIRST FLOOR, UPON REQUESTING THE COMPETENT PERSON ONSITE FOR S
#39558918J
Nov 20, 2026
PENDING
$5,000
Sep 8, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED EGRESS LADDER GOING UP FROM THE 1ST FLOOR TO THE 2ND FLOOR WAS INADEQUATE THE LADDER WAS NOT EXTENDING 3 FT ABOVE AND WAS NOT
#39558928N
Nov 20, 2026
PENDING
$2,500
Sep 8, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION RESPONDING TO AN INCIDENT, I OBSERVED CONSTRUCTION LOADS PLACED ON COLD-FORMED STEEL FLOOR FRAMING PRIOR TO VERIFICATION BY THE REQUIRED SPECIAL INSPECTOR THAT THE FLOOR WAS IN COMPLIA
#39558915Y
Nov 20, 2026
PENDING
$5,000
Sep 8, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF AN 2 STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED AT EXPOSURE#2 ADJACENT PROPERTY REAR YARD THAT THE WAS NOT OVERHEAD PROTECTION FOR WITHIN 20FT, TO PREVENT FALLING MATERIALS
#39558921K
Nov 20, 2026
PENDING
$5,000
Sep 8, 2026Unknown CLASS - 1
ATOI, OBSERVED WORKERS UTILIZING AN IMPROPERLY CONSTRUCTED TEMPORARY WORKING PLATFORM CONSISTING OF WOOD PLANKING AND PLYWOOD THAT WAS NOT CONSTRUCTED WITH THE REQUIRED MINIMUM 2-INCH PLANKING, PROPERLY SPANNED
#39558916X
Nov 20, 2026
PENDING
$5,000
Sep 8, 2026Unknown CLASS - 1
RESPONDING TO AN INCIDENT INVOLVING 2-WORKERS GETTING HURT, I OBSERVED A PARTIAL COLLAPSE OF THE 2ND-FLOOR SEVERAL STEEL FLOOR JOISTS WERE BENT, DISPLACED, AND COLLAPSED. CONSTRUCTION DEBRIS/MATERIALS WERE PRES
#39558914M
Nov 20, 2026
$10,000
Sep 8, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED AN OXYGEN GAS CYLINDER STORED UNSECURED BEHIND THE PORTABLE TOILET WITHOUT AN APPROVED STORAGE CAGE OR ADEQUATE PROTECTION FROM IMPACT. NO FDNY PERMIT WAS PROVIDED. THIS CO
#39558922M
Nov 20, 2026
$2,500
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 10, 2026DOBCONSTRUCTION: EMGY WK:PRTL INCOMPTE,UNSPPRTED CFS JSTS @ EXP1/4, LOADED & PRTLLY COLLPSED DURING CONSTN.ADDTL HVY MTRL LOADING ON 2FL POSES HZD REMEDY:RETAIN NYSPE & CS TO STBLZE SITE, RMV MTRL & DEBRIS.SBMT SS RPT BY 9/10/26 & EMCY WK PLANS BY 12P 9/11/26. DAILY SS RPTS.FILE W/IN 2 B-DAYSClosed
Sep 8, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, I OBSERVED ADJACENT PROPERTIES EXPOSURE#2-4 WITHIN 20FT OF THE CONSTRUCTION SITE, WINDOW WERE NOT PROPERLY COVER OR PROTECTED FROM FALLING AND FLYING DEBRIS,Open
Sep 8, 2026ECBConstruction: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE CONSTRUCTION WAS IN PROGRESS, AT THE 2ND-FLOOR DECK, MULTIPLE SECTIONS OF THE OPEN PERIMETER AND LEADING EDGES LACKED REQUIRED GUARDRAILS, EXOpen
Sep 8, 2026ECBSite Safety: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSE, UPON REQUEST SITE SAFETY PLAN, STRUCTURAL PLAN, PRE SHIFT MEETING, AND APPROVED DESIGN DRAWING FOOpen
Sep 8, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSED WITH MATERIALS ON 2-WORKERS ON THE FIRST FLOOR, UPON REQUESTING THE COMPETENT PERSON ONSITE FOR SOpen
Sep 8, 2026ECBUnknown: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED EGRESS LADDER GOING UP FROM THE 1ST FLOOR TO THE 2ND FLOOR WAS INADEQUATE THE LADDER WAS NOT EXTENDING 3 FT ABOVE AND WAS NOTOpen
Sep 8, 2026ECBUnknown: AT THE TIME OF INSPECTION RESPONDING TO AN INCIDENT, I OBSERVED CONSTRUCTION LOADS PLACED ON COLD-FORMED STEEL FLOOR FRAMING PRIOR TO VERIFICATION BY THE REQUIRED SPECIAL INSPECTOR THAT THE FLOOR WAS IN COMPLIAOpen
Sep 8, 2026ECBUnknown: AT THE TIME OF INSPECTION OF AN 2 STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED AT EXPOSURE#2 ADJACENT PROPERTY REAR YARD THAT THE WAS NOT OVERHEAD PROTECTION FOR WITHIN 20FT, TO PREVENT FALLING MATERIALSOpen
Sep 8, 2026ECBUnknown: ATOI, OBSERVED WORKERS UTILIZING AN IMPROPERLY CONSTRUCTED TEMPORARY WORKING PLATFORM CONSISTING OF WOOD PLANKING AND PLYWOOD THAT WAS NOT CONSTRUCTED WITH THE REQUIRED MINIMUM 2-INCH PLANKING, PROPERLY SPANNEDOpen
Sep 8, 2026ECBUnknown: RESPONDING TO AN INCIDENT INVOLVING 2-WORKERS GETTING HURT, I OBSERVED A PARTIAL COLLAPSE OF THE 2ND-FLOOR SEVERAL STEEL FLOOR JOISTS WERE BENT, DISPLACED, AND COLLAPSED. CONSTRUCTION DEBRIS/MATERIALS WERE PRESClosed
Sep 8, 2026ECBUnknown: AT THE TIME OF INSPECTION, I OBSERVED AN OXYGEN GAS CYLINDER STORED UNSECURED BEHIND THE PORTABLE TOILET WITHOUT AN APPROVED STORAGE CAGE OR ADEQUATE PROTECTION FROM IMPACT. NO FDNY PERMIT WAS PROVIDED. THIS COClosed