1 floors · 8,025 sq ft · built 1965 · class O1 · owner of record: 477 Willis Ave Ii Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 799 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 8, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, I OBSERVED ADJACENT PROPERTIES EXPOSURE#2-4 WITHIN 20FT OF THE CONSTRUCTION SITE, WINDOW WERE NOT PROPERLY COVER OR PROTECTED FROM FALLING AND FLYING DEBRIS, #39558929P | Nov 20, 2026 PENDING | $2,500 |
| Sep 8, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE CONSTRUCTION WAS IN PROGRESS, AT THE 2ND-FLOOR DECK, MULTIPLE SECTIONS OF THE OPEN PERIMETER AND LEADING EDGES LACKED REQUIRED GUARDRAILS, EX #39558919L | Nov 20, 2026 PENDING | $5,000 |
| Sep 8, 2026 | Site Safety CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSE, UPON REQUEST SITE SAFETY PLAN, STRUCTURAL PLAN, PRE SHIFT MEETING, AND APPROVED DESIGN DRAWING FO #39558917H | Nov 20, 2026 PENDING | $2,500 |
| Sep 8, 2026 | Unknown CLASS - 1 AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSED WITH MATERIALS ON 2-WORKERS ON THE FIRST FLOOR, UPON REQUESTING THE COMPETENT PERSON ONSITE FOR S #39558918J | Nov 20, 2026 PENDING | $5,000 |
| Sep 8, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED EGRESS LADDER GOING UP FROM THE 1ST FLOOR TO THE 2ND FLOOR WAS INADEQUATE THE LADDER WAS NOT EXTENDING 3 FT ABOVE AND WAS NOT #39558928N | Nov 20, 2026 PENDING | $2,500 |
| Sep 8, 2026 | Unknown CLASS - 1 AT THE TIME OF INSPECTION RESPONDING TO AN INCIDENT, I OBSERVED CONSTRUCTION LOADS PLACED ON COLD-FORMED STEEL FLOOR FRAMING PRIOR TO VERIFICATION BY THE REQUIRED SPECIAL INSPECTOR THAT THE FLOOR WAS IN COMPLIA #39558915Y | Nov 20, 2026 PENDING | $5,000 |
| Sep 8, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION OF AN 2 STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED AT EXPOSURE#2 ADJACENT PROPERTY REAR YARD THAT THE WAS NOT OVERHEAD PROTECTION FOR WITHIN 20FT, TO PREVENT FALLING MATERIALS #39558921K | Nov 20, 2026 PENDING | $5,000 |
| Sep 8, 2026 | Unknown CLASS - 1 ATOI, OBSERVED WORKERS UTILIZING AN IMPROPERLY CONSTRUCTED TEMPORARY WORKING PLATFORM CONSISTING OF WOOD PLANKING AND PLYWOOD THAT WAS NOT CONSTRUCTED WITH THE REQUIRED MINIMUM 2-INCH PLANKING, PROPERLY SPANNED #39558916X | Nov 20, 2026 PENDING | $5,000 |
| Sep 8, 2026 | Unknown CLASS - 1 RESPONDING TO AN INCIDENT INVOLVING 2-WORKERS GETTING HURT, I OBSERVED A PARTIAL COLLAPSE OF THE 2ND-FLOOR SEVERAL STEEL FLOOR JOISTS WERE BENT, DISPLACED, AND COLLAPSED. CONSTRUCTION DEBRIS/MATERIALS WERE PRES #39558914M | Nov 20, 2026 | $10,000 |
| Sep 8, 2026 | Unknown CLASS - 2 AT THE TIME OF INSPECTION, I OBSERVED AN OXYGEN GAS CYLINDER STORED UNSECURED BEHIND THE PORTABLE TOILET WITHOUT AN APPROVED STORAGE CAGE OR ADEQUATE PROTECTION FROM IMPACT. NO FDNY PERMIT WAS PROVIDED. THIS CO #39558922M | Nov 20, 2026 | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 10, 2026 | DOB | CONSTRUCTION: EMGY WK:PRTL INCOMPTE,UNSPPRTED CFS JSTS @ EXP1/4, LOADED & PRTLLY COLLPSED DURING CONSTN.ADDTL HVY MTRL LOADING ON 2FL POSES HZD REMEDY:RETAIN NYSPE & CS TO STBLZE SITE, RMV MTRL & DEBRIS.SBMT SS RPT BY 9/10/26 & EMCY WK PLANS BY 12P 9/11/26. DAILY SS RPTS.FILE W/IN 2 B-DAYS | Closed |
| Sep 8, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, I OBSERVED ADJACENT PROPERTIES EXPOSURE#2-4 WITHIN 20FT OF THE CONSTRUCTION SITE, WINDOW WERE NOT PROPERLY COVER OR PROTECTED FROM FALLING AND FLYING DEBRIS, | Open |
| Sep 8, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE CONSTRUCTION WAS IN PROGRESS, AT THE 2ND-FLOOR DECK, MULTIPLE SECTIONS OF THE OPEN PERIMETER AND LEADING EDGES LACKED REQUIRED GUARDRAILS, EX | Open |
| Sep 8, 2026 | ECB | Site Safety: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSE, UPON REQUEST SITE SAFETY PLAN, STRUCTURAL PLAN, PRE SHIFT MEETING, AND APPROVED DESIGN DRAWING FO | Open |
| Sep 8, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NB, RESPONDING TO AN INCIDENT WHERE THE 2ND FLOOR DECK COLLAPSED WITH MATERIALS ON 2-WORKERS ON THE FIRST FLOOR, UPON REQUESTING THE COMPETENT PERSON ONSITE FOR S | Open |
| Sep 8, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION OF A 2-STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED EGRESS LADDER GOING UP FROM THE 1ST FLOOR TO THE 2ND FLOOR WAS INADEQUATE THE LADDER WAS NOT EXTENDING 3 FT ABOVE AND WAS NOT | Open |
| Sep 8, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION RESPONDING TO AN INCIDENT, I OBSERVED CONSTRUCTION LOADS PLACED ON COLD-FORMED STEEL FLOOR FRAMING PRIOR TO VERIFICATION BY THE REQUIRED SPECIAL INSPECTOR THAT THE FLOOR WAS IN COMPLIA | Open |
| Sep 8, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION OF AN 2 STORY PROPOSED NEW BUILDING, ACTIVE SITE I OBSERVED AT EXPOSURE#2 ADJACENT PROPERTY REAR YARD THAT THE WAS NOT OVERHEAD PROTECTION FOR WITHIN 20FT, TO PREVENT FALLING MATERIALS | Open |
| Sep 8, 2026 | ECB | Unknown: ATOI, OBSERVED WORKERS UTILIZING AN IMPROPERLY CONSTRUCTED TEMPORARY WORKING PLATFORM CONSISTING OF WOOD PLANKING AND PLYWOOD THAT WAS NOT CONSTRUCTED WITH THE REQUIRED MINIMUM 2-INCH PLANKING, PROPERLY SPANNED | Open |
| Sep 8, 2026 | ECB | Unknown: RESPONDING TO AN INCIDENT INVOLVING 2-WORKERS GETTING HURT, I OBSERVED A PARTIAL COLLAPSE OF THE 2ND-FLOOR SEVERAL STEEL FLOOR JOISTS WERE BENT, DISPLACED, AND COLLAPSED. CONSTRUCTION DEBRIS/MATERIALS WERE PRES | Closed |
| Sep 8, 2026 | ECB | Unknown: AT THE TIME OF INSPECTION, I OBSERVED AN OXYGEN GAS CYLINDER STORED UNSECURED BEHIND THE PORTABLE TOILET WITHOUT AN APPROVED STORAGE CAGE OR ADEQUATE PROTECTION FROM IMPACT. NO FDNY PERMIT WAS PROVIDED. THIS CO | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 9:22 AM ET. BBL 2023070046.