Bronx · Block 5102 · Lot 27 · 10470

4747 Bronx Boulevard

2 floors · 43,700 sq ft · built 1926 · class H4 · owner of record: 4747 Bronx Boulevard Realty Llc

4open violations
$9,450ECB/OATH penalties owed
0HPD class C (immediately hazardous)
190dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 43,700 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 434 days
Next cycle year 2027

Open violations

ECB / OATH (5) · $9,450 owed
IssuedViolationHearingBalance
Aug 20, 2026Elevators CLASS - 1
CLASS 1 CEASE USE: 1. DOOR ZONE RESTRICTOR DEVICE FOUND INOPERATIVE AS PER CODE ASME A17.1/CSA B44 - SECTION 2.26.5. ELEVATOR CAR DOORS CAN BE OPENED WHEN THE CAR IS NOT WITHIN THE DESIGNATED DOOR ZONE, CREATIN
#39201291N
Oct 30, 2026
$1,250
Aug 20, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OBSERVED PAINTED SPRINKLER CAPS THROUGH OUT THE BUILDING SPRINKLER CAPS ARE NOT TO BE PAINTED AS PER FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES T
#39201195N
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Unknown CLASS - 2
MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED ON THE ROOF THE HOT WATER TANK REMOTE HAS NO REMOTE SHUTDOWN AT THE POINT ENTRY / EGRESS. MUST PROVIDE SHUT DOWN AT POINT OF EGRESS F
#39201200Z
Oct 30, 2026
PENDING
$800
Aug 20, 2026Unknown CLASS - 2
FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE MAIN ELECTRICAL AND THE POINT OF ENTRY NO INSTALLATION OF ELECTRODE GROUND ROD. IN THE MAIN WATER METER ROOM THE MAIN HOUSE WATER GRO
#39201199K
Oct 30, 2026
PENDING
$2,400
Aug 20, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OBSERVED NEW HOT WATER HEATERS INSTALLED IN THE BOILER ROOM ON THE ROOF WITH NO PERMITS ON FILE CHECKED BIS/DOBNOW CONTRARY TO PC 106.1 PLUMBING WORK, INCLUDING WATER HEATER INSTALLATI
#39201194L
Oct 30, 2026
PENDING
$2,500
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 20, 2026ECBElevators: CLASS 2: 1. CATEGORY 1 TEST TAG MISSING AND NOT DISPLAYING REQUIRED TEST INFORMATION. AS PER ASME A17.1 8.6.1.7. REMEDY: POST VALID CATEGORY 1 TEST TAG WITH CURRENT TEST DATE. 2. MAINTENANCE LOG BOOK FOR CURRENClosed
Aug 20, 2026ECBElevators: CLASS 1 CEASE USE: 1. DOOR ZONE RESTRICTOR DEVICE FOUND INOPERATIVE AS PER CODE ASME A17.1/CSA B44 - SECTION 2.26.5. ELEVATOR CAR DOORS CAN BE OPENED WHEN THE CAR IS NOT WITHIN THE DESIGNATED DOOR ZONE, CREATINClosed
Aug 20, 2026ECBElevators: 1. CATEGORY 1 TEST TAG MISSING AND NOT DISPLAYING REQUIRED TEST INFORMATION. AS PER ASME A17.1 8.6.1.7. REMEDY: POST VALID CATEGORY 1 TEST TAG WITH CURRENT TEST DATE. 2. MAINTENANCE LOG BOOK FOR CURRENT YEAR MIClosed
Aug 20, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED PAINTED SPRINKLER CAPS THROUGH OUT THE BUILDING SPRINKLER CAPS ARE NOT TO BE PAINTED AS PER FGC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES TOpen
Aug 20, 2026ECBUnknown: MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED ON THE ROOF THE HOT WATER TANK REMOTE HAS NO REMOTE SHUTDOWN AT THE POINT ENTRY / EGRESS. MUST PROVIDE SHUT DOWN AT POINT OF EGRESS FOpen
Aug 20, 2026ECBUnknown: FAILURE TO PROVIDE ADEQUATE GROUNDING OF ELECTRICAL SYSTEMS. OBSERVED IN THE MAIN ELECTRICAL AND THE POINT OF ENTRY NO INSTALLATION OF ELECTRODE GROUND ROD. IN THE MAIN WATER METER ROOM THE MAIN HOUSE WATER GROOpen
Aug 20, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED NEW HOT WATER HEATERS INSTALLED IN THE BOILER ROOM ON THE ROOF WITH NO PERMITS ON FILE CHECKED BIS/DOBNOW CONTRARY TO PC 106.1 PLUMBING WORK, INCLUDING WATER HEATER INSTALLATIOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 1:44 AM ET. BBL 2051020027.