2 floors · 3 apartments · 2,400 sq ft · built 1925 · class C0 · owner of record: 473 East 52 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 410 days | Next cycle year 2027 |
None open.
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 17) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 8, 2026 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT YARD BUIDLING FRONT | Oct 13, 2026 |
| Apr 3, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT CELLAR AT BOILER ROOM | Apr 9, 2026 |
| Apr 3, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 8, 2026 |
| Apr 3, 2026 | B | Apt 2FL · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER AND LOWER SASH WINDOWS IN THE 1st ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 8, 2026 |
| Apr 3, 2026 | B | Apt 2FL · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 8, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 HMC: REFIT DOORS AT EAST WALL IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE FOYER LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE FOYER LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30 AQUARE AT CEILING IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | C | Apt 2FL · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 28, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT RADIATOR IN THE 1st ROOM FROM EAST LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN CLOSETS IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | A | Apt 2FL · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Apr 2, 2026 | A | Apt 2FL · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE CERAMIC TILE GROUT JOINTS AT PEREMETER AT BATH TUB IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 6, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | B | Apt 2FL · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 7, 2026 |
| Apr 2, 2026 | C | Apt 2FL · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT ALL ELECTRICAL LIGHT FIXTURE AND OUTLET IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 8, 2026 |
| Apr 1, 2026 | C | Apt 2FL · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 1, 2026 |
| Mar 10, 2026 | B | Apt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAT 10 SQFT AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18349357 ISSUED 05-NOV-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-201 | Apr 14, 2026 |
| Mar 10, 2026 | B | Apt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING LESS THAN 10 SQUARE FEET IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18349353 ISSUED 05-NOV-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIV | Apr 14, 2026 |
| Nov 12, 2025 | B | § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT PUBLIC HALL STAIRS | Dec 17, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT CEILING LIGHT FIXTURES IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 15, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 15, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAS | Dec 15, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTELINE SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 15, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 15, 2025 |
| Nov 10, 2025 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 6, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK ABOVE THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 15, 2025 |
| Nov 10, 2025 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 6, 2025 |
| Nov 10, 2025 | B | Apt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CLOSET CEILING GREATER THAN 10 SQUARE FEET IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 15, 2025 |
| Aug 29, 2025 | B | Apt 2ND FL · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 2ND FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 3, 2025 |
| Aug 29, 2025 | C | Apt 2ND FL · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2ND FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 24, 2025 |
| Aug 29, 2025 | B | Apt 2ND FL · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2ND FL, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 3, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 8, 2026 | HPD B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR AT YARD BUIDLING FRONT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 16, 2026, 3:15 AM ET. BBL 3047240052.