1 floors · 5,400 sq ft · built 1928 · class K1 · owner of record: 4712 Wp Ch Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2022-03-29 (Accepted). Agency page | Dec 31, 2026 in 62 days | 1 of 1 without an accepted 2026 report yet |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 427 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 13, 2026 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. AT TIME OF INSPECTION, OBSERVED THE RETAINING WALL REMAINS IN A DETERIORATED CONDITION. RESPONDENT FAILED TO COMPLY WITH FEU ORDERS TO REPAIR THE #39177276H | May 1, 2026 DEFAULT | $12,500 |
| Feb 13, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED THE CEILING IN A DETERIORATED CONDITION, WITH DAMAGED AND SAGGING MATERIALS CREATING AN UNSAFE CONDITION FOR OCCUPANTS. R #39177264K | May 1, 2026 DEFAULT | $6,250 |
| Feb 13, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, NO COFC ON FILE. RECORDS INDICATE JOB PERMITTED AND SIGNED OFF UNDER #39177242J | May 1, 2026 DEFAULT | $6,250 |
| Aug 14, 2024 | Construction CLASS - 2 JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. I OBSERVED A CONSTRUCTION FENCE ERECTED WITH NO PERMIT. FENCE APPLICATION #X00783634 WAS APPROVED, HOWEVER IT WAS NOT PERMITTED AT THIS TIME, #39121857N | Mar 4, 2025 IN VIOLATION | $0 |
| Aug 14, 2024 | Construction CLASS - 2 WORK WITHOUT A PERMIT. I OBSERVED NEW CONCRETE BLOCK EXTERIOR WALLS ERECTED WITH NO ACTIVE PERMIT. FACADE APPLICATION #X00783633 WAS APPROVED, HOWEVER NOT PERMITTED AT THIS TIME, OBTAIN ALL PERMITS; SUBMIT THE #39121861X | Mar 4, 2025 IN VIOLATION | $0 |
| Mar 4, 2024 | Construction CLASS - 1 NOTED AT A SEMI DETACHED REAR GARAGE LOCATED IN ALLEY THAT APROX 8 FT OF CMU WALL HAS COLLAPSED AT EXP 2 LEAVING REAR EXP 3 WALL UNSUPPORTED., REPAIR AND/REPLACE; SUPPORT REAR WALL. #39107678R | Feb 20, 2026 IN VIOLATION | $0 |
| Nov 12, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED CELLAR SPACES CONCERNING 4712 AND 4714 WHITE PLAINS ROAD HAVING DEFECTIVE,LOOSE CMU WALL TO DIVIDE CELLAR SPACE WITH MISSING,LOOSE AND DECREPT CONDI #35581820L | Feb 4, 2022 DEFAULT | $6,250 |
| Oct 18, 2006 | Construction Non-Hazardous FAILURE TO MAINTAIN. 5 3 X 12 WOOD FLOOR JOISTS ROTTED & DEFECTIVE. 1 2 X 12 WOOD(HEADER)FLOOR JOISTS ARE ATTACHED TO IS ROTTED & DEFECTIVE.CAUSING REAR OF 1ST FL TO BECOME UNSTABLE. REMEDY:MAKE ALL NECESSARY #34540238Z | Dec 1, 2006 IN VIOLATION | $0 |
| Oct 18, 2006 | Construction Non-Hazardous FAILURE TO MAINTAIN. WOOD STAIR CASE LEADING FORM 1ST FL TO BASEMENT ROTTED & DEFECTIVE. (NOTE)STAIR CASE IS ILLEGAL AS PER VIO #34540239K 101806C12FG07.REMEDY"MAKE ALL NECESSARY REPAIRS OR REMOVE STAIRS. #34540240H | Feb 16, 2007 IN VIOLATION | $0 |
| Oct 18, 2006 | Construction Non-Hazardous WORK W/O PERMITS. HAVING CUT 4 FL JOISTS AT 1ST FL TO CREATE OPENING TO BASEMENT:INSTALLED WOOD STAIRS. REMEDY:OBTAIN ALL NECESSARY PERMITS OR RESTORE TO PRIOR LEGAL CONDITION. #34540239K | Feb 16, 2007 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 26, 2024 | CONSTRUCTION FTM.DUE TO PARTIAL COLLAPSE@NEIGHBORNG 4712 REAR WHITE PLAINS ROAD, OBSRVD DAMAGED BRICK MASONRY BEARNG WALL@EXPOSURE 3/4 CORNER.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #030524FEU21205AK #FEU21201AK | DOB VIOLATION - ACTIVE |
| Mar 26, 2024 | CONSTRUCTION FTM.AT REAR OF PROPERTY,OBSRVD BLOCK RETAINING WALL APPRX 25'LONG X 4'HIGH IN DISREPAIR.OBRVD RETAINING WALL CRCKD,BULGING,&LEANING TOWARDS 4612 REAR WHITE PLAINS ROAD PROPERTY.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #030524FEU21204AK #FEU21202AK | DOB VIOLATION - ACTIVE |
| Mar 5, 2024 | CONSTRUCTION FTM.DUE TO PARTIAL COLLAPSE@NEIGHBORNG 4712 REAR WHITE PLAINS ROAD, OBSRVD DAMAGE BRICK MASONRY BEARNG WALL@EXPOSYRE 3/4 CORNER.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION #030524FEU21205AK #FEU21203AK | DOB VIOLATION - ACTIVE |
| Mar 5, 2024 | IMMEDIATE EMERGENCY FULLY DEMOLISH BUILDING GRADE AND FENCE SITE #18227 | DOB VIOLATION - ACTIVE |
| Mar 5, 2024 | CONSTRUCTION FTM.AT REAR PROPERTY,OBSRVD BLOCK RETAINING WALL APPROX 25'LONG X 4' HIGH IN DISREPAIR.OBSRVD RETAINING WALL CRCKD,BULGING,&LEANING TOWARDS 4612 REAR WHITE PLAINS ROAD PROPERTY.COMPLY WITH COMMISSIONER'S ORDER: DOB VIOLATION #030524FEU21204AK #FEU21204AK | DOB VIOLATION - ACTIVE |
| Oct 24, 2022 | STRUCTURALLY COMPROMISED BUILDING FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISED BLDG. #00007 | DOB VIOLATION - ACTIVE |
| Jul 19, 2022 | CONSTRUCTION FAIL TO MAINTAIN BLDG-@FRONT EXP@SIDEWLK HATCH,A COLUMN SUPPRTNG ROOF FRAMNG& PARPT UNSUPPRTD.SUPPRTNG STEEL LINTL SEVRLY CORRDED &NO LONGER PROVDNG SUPPRT.FLOODED CELLR.ROTTN BEARNG ENDS 1FL JOISTS.OPNING @ROOF DUE TO FIRE & FF OPS.OWNR RTAIN NYS-LIC PE& CNTRCTR-EVAL ENTIRE BLDG & RPR UNDER PRMT.FI #FEU21202IK | DOB VIOLATION - ACTIVE |
| Jul 19, 2022 | CONSTRUCTION EMRGCY WORK-@FRNT EXP@SIDEWLK HATCH A COLUMN SUPPRTNG ROOFFRAMNG &BRCK PARAPT UNSUPPRTD &APPEARD DISPLCD DOWNWRD.SUPPRTNG STEEL LINTL SEVRLY CORRODED &NO PROVIDED SUPPRT.DIAGONAL CRCKNG OF PARAPT OWNR IMMED RTAIN NYS-LIC PE& CNTRCTR-DSGN &INSTLL SHORNG OF UNSUPPRTD COLUMN & STRCTRL ELEMNT NECESSRY.W #FEU21201IK | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #15962 | DOB VIOLATION - ACTIVE |
| May 16, 1991 | CONSTRUCTION #10J4 | VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE |
| Nov 13, 1990 | ELECTRIC SIGNS #ST01W | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Oct 24, 2022 | Structurally Compromised Buildings FTF-SC-INITL | Active |
None open.