2 floors · 3 apartments · 3,240 sq ft · built 1910 · class C0 · owner of record: The 4712 Fort Hamilton Pkwy Trust
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 56 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 56 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 72 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 421 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 18, 2026 | Construction CLASS - 1 ON ARRIVAL AT EXPOSURE # 1, WORKERS ARE CONDUCTING CONCRETE PUMPING, AND TRANSFERRING CEMENT THROUGH STEEL PIPE INTO REAR YARD, WHICH IS IN VIOLATION OF PARTIAL STOP WORK ORDER # OP - 71 - 26 - 10015, COMPLY WI #39204754Y | Nov 25, 2026 PENDING | $10,000 |
| Sep 17, 2026 | Construction CLASS - 1 NEW RENOVATIONS/CONSTRUCTION REGARDING ENLARGEMENT DONE IN REAR YARD REGARDING BEAMS, AND CANOPY. 25 FOOT BY 25 FOOT HORIZONTAL ENLARGEMENT AT REAR YARD WITH Q DECKING, AND HIGH BEAMS INSTALLED FOR VERTICAL SUP #39204460Z | Nov 25, 2026 PENDING | $2,500 |
| Sep 17, 2026 | Construction CLASS - 1 IN REAR YARD, NO FALL PROTECTION OR GUARDRAILS ON OPENING WHERE LADDER IS OBSERVED. WIRES, LADDERS, AND OTHER EQUIPMENT BEING UNMAINTAINED ON TOP AND BELOW OF ENLARGEMENT, REPAIR AND/REPLACE; REPLACE AND/OR REP #39204461K | Nov 25, 2026 PENDING | $2,500 |
| Sep 17, 2026 | Construction CLASS - 1 1RCNY TABLE 1 (STREET). STRUCTURE BEING ILLEGAL BUILT UP TO LOT LINE, CREATING HAZARDOUS CONDITIONS JUST IN CASE OF EMERGENCY RESPONDERS, REPAIR AND/REPLACE; REPLACE AND/OR REPAIR #39204462M | Nov 25, 2026 PENDING | $2,500 |
| Sep 17, 2026 | Construction CLASS - 1 ON BALCONY OF PROPERTY (2ND FLOOR) OBSERVED FROM ADJACENT PROPERTY (4710 FORT HAMILTON PKWY) FROM ROOF, APPROXIMATELY 5 FOOT BY 8 FOOT WITH STEEL COLUMNS, METAL BASE, AND NO ACTIVE PERMITS REGARDING STRUCTURE, #39204463Y | Nov 25, 2026 PENDING | $2,500 |
| Sep 17, 2026 | Construction CLASS - 1 IN REAR YARD, INSTALLED ELECTRIC WIRES FOR THREE AC UNITS WITHOUT ACTIVE PERMITS, OBTAIN PERMIT; OBTAIN PERMITS #39204464X | Nov 25, 2026 PENDING | $2,500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 18, 2026 | ECB | Construction: ON ARRIVAL AT EXPOSURE # 1, WORKERS ARE CONDUCTING CONCRETE PUMPING, AND TRANSFERRING CEMENT THROUGH STEEL PIPE INTO REAR YARD, WHICH IS IN VIOLATION OF PARTIAL STOP WORK ORDER # OP - 71 - 26 - 10015, COMPLY WI | Open |
| Sep 17, 2026 | ECB | Construction: NEW RENOVATIONS/CONSTRUCTION REGARDING ENLARGEMENT DONE IN REAR YARD REGARDING BEAMS, AND CANOPY. 25 FOOT BY 25 FOOT HORIZONTAL ENLARGEMENT AT REAR YARD WITH Q DECKING, AND HIGH BEAMS INSTALLED FOR VERTICAL SUP | Open |
| Sep 17, 2026 | ECB | Construction: IN REAR YARD, NO FALL PROTECTION OR GUARDRAILS ON OPENING WHERE LADDER IS OBSERVED. WIRES, LADDERS, AND OTHER EQUIPMENT BEING UNMAINTAINED ON TOP AND BELOW OF ENLARGEMENT, REPAIR AND/REPLACE; REPLACE AND/OR REP | Open |
| Sep 17, 2026 | ECB | Construction: 1RCNY TABLE 1 (STREET). STRUCTURE BEING ILLEGAL BUILT UP TO LOT LINE, CREATING HAZARDOUS CONDITIONS JUST IN CASE OF EMERGENCY RESPONDERS, REPAIR AND/REPLACE; REPLACE AND/OR REPAIR | Open |
| Sep 17, 2026 | ECB | Construction: ON BALCONY OF PROPERTY (2ND FLOOR) OBSERVED FROM ADJACENT PROPERTY (4710 FORT HAMILTON PKWY) FROM ROOF, APPROXIMATELY 5 FOOT BY 8 FOOT WITH STEEL COLUMNS, METAL BASE, AND NO ACTIVE PERMITS REGARDING STRUCTURE, | Open |
| Sep 17, 2026 | ECB | Construction: IN REAR YARD, INSTALLED ELECTRIC WIRES FOR THREE AC UNITS WITHOUT ACTIVE PERMITS, OBTAIN PERMIT; OBTAIN PERMITS | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 5, 2026, 8:14 PM ET. BBL 3056260025.