Brooklyn · Block 2216 · Lot 32 · 11249

47 Rutledge Street

1 floors · 8,032 sq ft · built 1931 · class F5 · owner of record: Hewes Irrevocable Trust

41open violations
$2,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
798dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 798 days
Next cycle year 2028

Open violations

ECB / OATH (17) · $2,500 owed
IssuedViolationHearingBalance
Jul 20, 2023Construction CLASS - 1
NOTED: OBSERVED THROUGHOUT THE CEILING THERE ARE HOLES ,AND MISSING FIRESTOPPING .
#39519543K
Sep 27, 2023
IN VIOLATION
$1,250
Jul 13, 2023Construction CLASS - 1
AT TIME OF INSPECTION, NO EGRESS PASSAGEWAYS OBSTRUCTED. HOWEVER, OBSERVED THE FACADE OF EXPOSURE #1 IN STATE OF DISREPAIR. MISSING/SPALLING BRICK, MORTAR JOINT AND MISSING COPING STONE FROM THE PARAPET AT THE
#39519197R
Sep 20, 2023
IN VIOLATION
$1,250
Dec 15, 2010Construction CLASS - 1
WORK W/O A PERMIT.NOTED WORK IN PROGRESS REMOVING 3PC BATHROOM SINK, TUB AND TOILET LOCATED BENEATH MEZZANINE AT FIRST FLOOR. REMEDY: OBTAIN PERMIT.
#34893600X
Feb 14, 2011
WRITTEN OFF
$0
Oct 2, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. CRACKS,LOOSE & MISSING BRICKS OBSERVED IN THE FRONT BRICK WALL. REMEDY: REPAIR EXTERIOR BUILDING WALL.
#34877864J
Feb 14, 2011
WRITTEN OFF
$0
Oct 2, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER. DUE TO THE PENETRATION OF RAIN WATER THE CEILING HAS ROTTED IN PLACES & HAS BECOME DISLODGED. ROTTING & MISSING FIRE STOP NOTED THROUGHOUT THE BUILDING.
#34877865L
Feb 14, 2011
WRITTEN OFF
$0
Aug 7, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES.NOTE:CRACKS,LOOSE & MISSING BRICKS OBSERVED IN THE FRONT BRICK WALL.REMEDY:REPAIR FRONT BRICK WALL.
#34863899M
Feb 14, 2011
WRITTEN OFF
$0
Aug 7, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.DUE TO THE PENETRATION OF RAIN WATER,THE CEILING HAS ROTTED IN PLACES & HAS BECOME DISLODGED.MISSING FIRE STOP (CEILING)NOTED THROUGHOUT & ROTTING/MISSING CEILI
#34862725H
Feb 14, 2011
WRITTEN OFF
$0
Feb 6, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BLDG WALL OR APPURTENANCES. NOTED: FRONT BRICKWALLWAS OBSERVED WITH CRACKS, LOOSE & MISSING BRICKS. REM: REPAIR EXTERIORBRICK WALL.
#34835112L
Mar 14, 2011
WRITTEN OFF
$0
Feb 6, 2010Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. DUE TO PENETRATION OF RAINWATER, THE CEILING IS ROTTING & HAS BECOME DISLODGED IN SEVERALPLACES. ROTTING & MISSING CEILING JOISTS. ALSO NOTED FURTHER, MISSING
#34835111J
Jul 25, 2011
WRITTEN OFF
$0
Sep 5, 2009Construction CLASS - 2
FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A CERT OF CORREC TION W/THE DOB. RESPONDENT FAILED TO COMPLY W/THE COMMISSIONER'S ORDERTO CORRECT THE VIOLATING CONDITION AND FILE A 'CERT OF CORRECTION'
#34804662Y
Oct 26, 2009
WRITTEN OFF
$0
Sep 5, 2009Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED: DUE TO RAIN WATER PENETRATION THE WOOD CEILING IS ROTTING AND HAS BECOME DISLODGEDIN SEVERAL PLACES. ROTTING AND MISSING CEILING JOIST & MISSING CEILING
#34804661M
Oct 26, 2009
WRITTEN OFF
$0
Sep 5, 2009Construction CLASS - 2
FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A CERT OF CORRECTION W/THE DOB. RESPONDENT FAILED TO COMPLY W/THE COMMISSIONER'S ORDER TO CORRECT THE VIOLATING CONDITION(S) AND FILE A CERT OF CORRECTION
#34804664H
Oct 26, 2009
WRITTEN OFF
$0
Apr 21, 2009Construction CLASS - 1
WORK W/O A PERMIT WORK NOTED INTERIOR PARTITION WALLS ERECTING TO CREATE TWO BDRMS AND THREE PIECE BTRM W/ TUB SINK AND TOILET LOCATED BENEATH MEZZANINE AT FIRST FL FRONT PLUMBING AND ELECTRICAL WORK INSTALLED
#34767317N
Jun 15, 2009
WRITTEN OFF
$0
Apr 21, 2009Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER NOTE ROTTEN AND SPLIT WOOD CHENG JOIST MISSING FIRE STOPPING AT CEILING HOLES IN CEILING CAUSING RAIN WATER TO LEAK MISSING BRICKS AT DOOR JAMBS AT ALL ENTR
#34767319R
Jun 15, 2009
WRITTEN OFF
$0
Apr 21, 2009Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY AND/OR BLDG DEPT RECORDS NOTE INDIVIDUAL SLEEPING QUARTERS TWO BDRM W/ BEDS DRESSERS ALARM CLOCKS TELEVISIONS TABLES AND CHAIRS AND THREE PIECE BTRM
#34767318P
Jun 15, 2009
WRITTEN OFF
$0
Feb 28, 2008Public Assembly Non-Hazardous
FAILURE TO PROVIDE EMERGENCEY POWER EXIT AND DIRECTIONAL SIGNS NOTED ACTIVE OPEN COMMERCIAL MATTRESS FACTORY WITH NO EMERGENCY POWER EXIT AND DIRECTIONAL SIGNS PROVIDE INSTALLED CREATING A HAZARDOUS CONDITIONS
#34634452R
Apr 22, 2009
WRITTEN OFF
$0
Feb 28, 2008Construction Hazardous
EXIT PASSAGEWAY TOTAL OBSTRUCTION NOTED REAR EGRESS TO COMMERCIAL MATTRESS FACTORY IS OBSTRUCTED WITH SALVAGE MATERIALS USE MATTRESS EQUIPMENT CREATING A HAZARDOUS CONDITION FOR WORKER REMEDY: REMOVE ALL
#34634451P
Jun 23, 2008
WRITTEN OFF
$0
DOB (13)
IssuedViolationStatus
Mar 23, 2011FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00101
DOB VIOLATION - ACTIVE
Jan 13, 2011FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00800
DOB VIOLATION - ACTIVE
Jan 13, 2011FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00799
DOB VIOLATION - ACTIVE
Jan 13, 2011FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00798
DOB VIOLATION - ACTIVE
Dec 2, 2010FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01110
DOB VIOLATION - ACTIVE
Dec 2, 2010FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01111
DOB VIOLATION - ACTIVE
May 4, 1998LOCAL LAW 62/91 - BOILERS

#21454
DOB VIOLATION - ACTIVE
Sep 16, 1997LOCAL LAW 62/91 - BOILERS

#225237
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#23023
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#29455
DOB VIOLATION - ACTIVE
Jun 1, 1994LOCAL LAW 62/91 - BOILERS

#13271
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#28054
DOB VIOLATION - ACTIVE
Jun 1, 1993LOCAL LAW 62/91 - BOILERS

#13270
DOB VIOLATION - ACTIVE
DOB NOW Safety (12)
IssuedViolationStatus
Mar 23, 2011AEUHAZ FTC-AEU-HAZ
Active
Jan 13, 2011AEUHAZ FTC-AEU-HAZ
Active
Jan 13, 2011AEUHAZ FTC-AEU-HAZ
Active
Jan 13, 2011AEUHAZ FTC-AEU-HAZ
Active
Dec 2, 2010AEUHAZ FTC-AEU-HAZ
Active
Dec 2, 2010AEUHAZ FTC-AEU-HAZ
Active
May 4, 1998Boiler LL6291
Active
Sep 16, 1997Boiler LL6291
Active
Feb 10, 1997Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
Jun 1, 1994Boiler LL6291
Active
Jun 1, 1993Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 12:34 AM ET. BBL 3022160032.