4 floors · 5 apartments · 5,320 sq ft · built 1915 · class S5 · owner of record: Nyc Tower 2619 Holdings Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-06-19 (Accepted). Agency page | Dec 31, 2026 in 44 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1140 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 2, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED ACTIVE DEMOLITION SITE. UPON INSPECTING SITE OBSERVED INADEQUATE HOUSEKEEPING ON ENTIRE SITE. ACCUMULATING DEBRIS WERE BLOCKING EGRESS PATHS AND CREATING TRIPPING HAZARDS. ALSO O #39558664Z | May 20, 2027 | $2,500 |
| Oct 11, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED APPROX. 12" HOLE AND CRACKS ON SIDEWALK CONCRETE THROUGH FRONT VAULT. ALSO OBSERVED I-BEAMS & METAL DECKING FOR SIDEWALK CONCRETE ROTTED, SECTION MISSING, DETERIORATED AND SEVEREL #39096851K | Dec 21, 2023 DEFAULT | $25,000 |
| Jul 3, 2023 | Construction CLASS - 3 FAILURE TO MAINTAIN BUILDING CODE COMPLIANT. NOTED: AT THE FRONT, THERE IS MASONRY STEP CRACKING UNDER THE WINDOWS OF THE THIRD AND FOURTH FLOORS ON THE RIGHT SIDE., REPAIR AND OR REPLACE; COMPLY WITH CODE. REP #39089649L | Sep 7, 2023 DEFAULT | $500 |
| Mar 7, 2007 | Boilers Non-Hazardous B4A/32A/44A/50/50A/50B/50C/50D/50E/50F/.50-STORAGE IN BOILER ROOM.50A-DEDICATED FRESH AIR TO BOILER ROOM ONLY,MISSING ALSO FIRE DAMPER MISSING.50B-BOTH PRESSURE CONTROL PIPED TO BOILER ON ONE 1/4 PIPE. #32053308Y | Apr 26, 2007 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 11, 2023 | CONSTRUCTION AT TIME OF INSPECTION OBSERVED APPROX. 12" HOLE AND CRACKS ON SIDEWALK CONCRETE THROUGH FRONT VAULT. ALSO OBSERVED I-BEAMS & METAL DECKING FOR SIDEWALK CONCRETE ROTTED, SECTION MISSING, DETERIORATED AND SEVERELY DAMAGED INSIDE THE VAULT & STRUCTURAL STABILITY COMPROMISED. #23-02842 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #35496 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #15283 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #36579 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #15913 | DOB VIOLATION - ACTIVE |
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #04054 | DOB VIOLATION - ACTIVE |
| Nov 24, 2015 | CONSTRUCTION DUE TO DRILL BIT PENETRATING WALL DURING TIE BACK AT THE EAST WALL OF APT. 4, THE FOLLOWING DAMAGE HAS OCCURRED. BROKEN PLASTER AND MOLDING DAMAGE BETWEEN THE CEILING AND THE WALL ADJACENT TO THE KITCHEN #CER01MH | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 5) | Active |
| Oct 25, 2024 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 9, 2023 | B | § 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AND RUBBISH AT PUBLIC HALL, 3rd STORY | Jun 13, 2023 |
| May 9, 2023 | B | § 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AND RUBBISH AT PUBLIC HALL, 4th STORY | Jun 13, 2023 |
| Feb 11, 2022 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING, SOUTH AND WEST WALLS AT PUBLIC HALL STAIRS, 2nd STORY | May 17, 2022 |
| Feb 11, 2022 | B | § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT EAST WALL AT PUBLIC HALL, 2nd STORY | Mar 18, 2022 |
| Feb 11, 2022 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WEST WALL AT PUBLIC HALL STAIRS, 2nd STORY | May 17, 2022 |
| Feb 11, 2022 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND NORTH WALL AT PUBLIC HALL STAIRS, 1st STORY | May 17, 2022 |
| Feb 11, 2022 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING, WEST AND NORTH WALLS AT PUBLIC HALL STAIRS, 1st STORY | May 17, 2022 |
| Sep 29, 2021 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME AT PUBLIC HALL, 1st STORY | Jan 2, 2022 |
| Sep 29, 2021 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT SOUTH AND WEST WALLS AT PUBLIC HALL, 2nd STORY | Jan 2, 2022 |
| Sep 29, 2021 | C | Apt 3 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Oct 25, 2021 |
| Sep 29, 2021 | B | Apt 3 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 3 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT SOUTH AND WEST WALLS AT PUBLIC HALL, 2nd STORY | Jan 2, 2022 |
| Sep 29, 2021 | A | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDENT MATERIAL AT CEILING, NORTH AND WEST WALLS AT PUBLIC HALL, 1st STORY | Jan 2, 2022 |
| Sep 29, 2021 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING, NORTH AND WEST WALLS AT PUBLIC HALL, 1st STORY | Jan 2, 2022 |
| Mar 19, 2021 | B | Apt 5 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE PRIVATE HALLWAY LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 23, 2021 |
| Mar 19, 2021 | B | Apt 5 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 23, 2021 |
| Mar 19, 2021 | B | Apt 5 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 23, 2021 |
| Mar 19, 2021 | B | Apt 5 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 23, 2021 |
| Mar 19, 2021 | B | Apt 5 · § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE BROKEN GLASS AT CEILING SKYLIGHT IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 23, 2021 |
| Mar 17, 2021 | C | Apt 3 · § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 17, 2021 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 2, 2026 | ECB | Construction: AT TIME OF INSPECTION OBSERVED ACTIVE DEMOLITION SITE. UPON INSPECTING SITE OBSERVED INADEQUATE HOUSEKEEPING ON ENTIRE SITE. ACCUMULATING DEBRIS WERE BLOCKING EGRESS PATHS AND CREATING TRIPPING HAZARDS. ALSO O | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 5:58 AM ET. BBL 1008600034.