Queens · Block 7330 · Lot 23 · 11361

47-02 Bell Boulevard

1 floors · 17,090 sq ft · built 1949 · class K1 · owner of record: Hansu Enterprises Inc

19open violations
$500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
432dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 432 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-18 (Pre-Filing-Pending Payment). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (6) · $500 owed
IssuedViolationHearingBalance
Jun 28, 2025Construction CLASS - 3
OCCUPANCY CONTRARY TO DEPARTMENT RECORDS. AT TIME OF INSPECTION SVHEDULE A NOTED ACCESSORY PARKING FOR 8 VEHICLES, DURING INSPECTION IT WAS OBSERVED TO BE APPROXIMATELY 20 CARS IN LOT., DISCONTINUE ILLEGAL OCCU
#39152274N
Oct 23, 2026
PENDING
$500
Dec 12, 2024Boilers CLASS - 2
FULTON FB10A HP BOILER WITH CORRODED LOWER RIGHT SIDE HAND HOLE SLEEVE. CORRECT VIOLATING CONDITION AND SUBMIT A CERTIFICATE OF CORRECTION.
#39132777R
Feb 18, 2025
ADMIT/IN-VIO
$0
Jul 30, 2024Construction CLASS - 2
WORK WITHOUT A PERMIT, NOTED AT REAR OF BUILDING. ERECTED A WOODEN FRAME STRUCTURE CREATING A STORAGE SHED. SHED MEASURES APPROX. 10FT X 12FT X 9FT. SHED APPEARS TO BE 100% FINISHED WITH DOOR, FLOORING, SIDING,
#39120266R
Dec 3, 2024
IN VIOLATION
$0
Jul 29, 2023Construction CLASS - 2
WORK WITHOUT A PERMIT. NOTED: AT REAR OF PREMISES ERECTED CANOPY APPROX. 60FT L X 30FT W X 15FT H 6 WOODEN POST & BEAMS WITH CLEAR PLASTIC CORRUGATED ROOF. INSTALLED ELECTRICAL WIRING FOR LIGHTS., OBTAIN ALL PE
#39091333H
May 7, 2024
IN VIOLATION
$0
Aug 12, 2008Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. LACK OF EMERGENCY LIGHTING FOR EXITS, EXIT DISCHARGE AND PUBLIC CORRIDORS PER BC 1006.1;27-542 INSP(DWG) 07-25-05 FOR JOB ALT II #402178157 OF WHICH PERMIT
#34693673K
Oct 7, 2008
IN VIOLATION
$0
Aug 12, 2008Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER; IMPROPER EXIT/EXIT ACCESS DOORWAY ARRANGEMENT PER BC 1014.2; 27-361 FOR JOB ALT II #402178157. AT THE TIME OF INSPECTION FOUND IMPROPER HARDWARE HARDWARE ON
#34693674M
Oct 7, 2008
IN VIOLATION
$0
DOB (6)
IssuedViolationStatus
Jun 20, 2023HIGH PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
#00287
DOB VIOLATION - ACTIVE
Jun 20, 2023HIGH PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
#01494
DOB VIOLATION - ACTIVE
Jun 20, 2023HIGH PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION
#03885
DOB VIOLATION - ACTIVE
Jul 15, 2005CONSTRUCTION

#111M
DOB VIOLATION - ACTIVE
Jan 18, 1990CONSTRUCTION
MIPERRO
#11M1
DOB VIOLATION - ACTIVE
May 25, 1989CONSTRUCTION
MP
#11M2
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 11)
Active
Nov 14, 2023Boiler FTC-BE-INT-HP
Violation Issued-Failure To File 2021 Internal Inspection Affirmation of Correction for HP Device
Active
Nov 14, 2023Boiler FTC-BE-INT-HP
Violation Issued-Failure To File 2020 Internal Inspection Affirmation of Correction for HP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-HP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for HP Device
Active
Jun 20, 2023Boiler HBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 INTERNAL HGH PRESSURE INSPECTION
Active
Jun 20, 2023Boiler HBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL HGH PRESSURE INSPECTION
Active
Jun 20, 2023Boiler HBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 INTERNAL HGH PRESSURE INSPECTION
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 6:05 PM ET. BBL 4073300023.

Look up another building