Manhattan · Block 2059 · Lot 57 · 10031

468 West 145 Street

3 floors · 6 apartments · 2,991 sq ft · built 1896 · class C5 · owner of record: Jjpb 468 W145 Llc

34open violations
$9,375ECB/OATH penalties owed
2HPD class C (immediately hazardous)
44dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 288 days
Registered through 2027-09-01

Open violations

ECB / OATH (9) · $9,375 owed
IssuedViolationHearingBalance
Sep 12, 2018Boilers CLASS - 2
B254,15,32A,50. DROP LEG ON RELIEF VALVE MISSING CORRECT A VIOLATING CONDITION AND SUBMIT CERTIFICATION OF CORRECTION.
#32097427L
Nov 1, 2018
DEFAULT
$3,125
Sep 12, 2018Boilers CLASS - 2
50,B254. SO HOT WATER HEATER DEFECTIVE. CORRECT VIOLATING CONDITION AND SUBMIT CERTIFICATION OF CORRECTIONS.
#32097428N
Nov 1, 2018
DEFAULT
$3,125
Sep 12, 2018Boilers CLASS - 2
B265(5C)FAILURE TO FILE A COMPLETE BOILER INSPECTION AS PER DOB RECORDS.SUBMIT AN INITIAL INSPECTION REPORT
#32097426J
Nov 1, 2018
DEFAULT
$3,125
May 12, 2017Boilers CLASS - 2
B265,50. 50-AS PER CLASS 2 (B265) 28-303.7 FAILURE TO FILE A COMPLETE BOILER INSPECTION REPORT AS PER DOB RECORDS. SUBIT A CURRENT B09 REPORT CORRECT ALL VIOLATING CONDITIONS AND SUBMIT THE CERTIFICATION OF
#32088295Y
Jun 29, 2017
WRITTEN OFF
$0
Mar 7, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: AT FRONT ENTRY,COLUMNS PEELING & RIGHT SIDE COLUMN HAS LARGE CRACK & SECTION HAS CRACKED & DETACHED,ALSO NOTE ABOVE 2ND FL WINDOW PEELING & CRACKING OF
#35219791J
Apr 27, 2017
WRITTEN OFF
$0
Jan 17, 2017Boilers CLASS - 2
15,16,24B,25B,34A,50,50A,50B,50,38. FOUND 1 WEIL MCLAIN EGH-95 BOILER NOT REGISTERED; 50-MISSING SPILL SWITCH; 50A-MISSING MANUAL RESET LOW WATER CUTOFF; 50B-OIL TANKS LEAKING;50C-MISSING CLEANOUT AT CHIMNEY
#32087104H
Mar 9, 2017
WRITTEN OFF
$0
Apr 11, 2015Boilers CLASS - 1
B154,1,51
#32075226H
May 28, 2015
WRITTEN OFF
$0
Apr 11, 2015Boilers CLASS - 1
B151,1,51
#32075227J
May 28, 2015
WRITTEN OFF
$0
Apr 4, 2015Boilers CLASS - 1
B154,50A,50B,50C.50A-FLUE PIPE NOT SEALED TO CHIMNEY, 50B-FLUE PIPE NEED SUPPORT, 50C-DO NOT OPERATE HOT WATER HEATER UNTIL ALL HAZARDOUS CONDITION ARE CORRECTED & DOB IS CALL FOR REINSPECTION TO LIFT THE CEASE
#32075144Y
May 21, 2015
WRITTEN OFF
$0
DOB (9)
IssuedViolationStatus
Sep 10, 2026LANDMARK

#27-0103
DOB VIOLATION - ACTIVE
Sep 10, 2026LANDMARK

#27-0104
DOB VIOLATION - ACTIVE
Sep 10, 2026LANDMARK

#27-0105
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#04483
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#04373
DOB VIOLATION - ACTIVE
Apr 8, 2024LANDMARK

#24-0816
DOB VIOLATION - ACTIVE
Jul 1, 2015FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00116
DOB VIOLATION - ACTIVE
Jul 1, 2015FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00117
DOB VIOLATION - ACTIVE
Jul 1, 2015FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00115
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 9)
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Jul 1, 2015AEUHAZ FTC-AEU-HAZ
Active
Jul 1, 2015AEUHAZ FTC-AEU-HAZ
Active
Jul 1, 2015AEUHAZ FTC-AEU-HAZ
Active
HPD (10) · C 2 · B 7 · A 0
IssuedClassViolationCorrect by
Oct 17, 2018I§ 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER UNTIL A NEW CERTIFICATE OF OCCUPANCY HAS BEEN OBTAINED.—
Oct 4, 2018B§ 27-2050 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT .... AT CELLARNov 8, 2018
Oct 4, 2018B§ 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT .. AT CELLARNov 8, 2018
Feb 14, 2018C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT PUBLIC HALL, 1st STORYFeb 22, 2018
Dec 8, 2015B§ 27-2044 ADM CODE REPLACE OR REPAIR THE SELF-CLOSING THE DOORS THAT IS MISSING OR DEFECTIVE AT ENTRANCEWAY TO BUILDING AT PUBLIC HALL, 1st STORYJan 12, 2016
Sep 23, 2015B§ 27-2050 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT ... AT CELLAROct 28, 2015
Sep 23, 2015B§ 27-2050 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT ... AT CELLAROct 28, 2015
Feb 2, 2015C§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE THE HINGES AT BUILDING ENTRANCE DOOR AT VESTIBULEFeb 10, 2015
Oct 31, 2014B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELLS FROM THE STOOP TO ALL STYS AT PUBLIC HALLDec 5, 2014
Jun 3, 2008B§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE TO 2 STY NORTH ROOM 6.Jul 8, 2008

Issued in the last 120 days

DateSourceWhatNow
Sep 10, 2026DOBLANDMARK: Open
Sep 10, 2026DOBLANDMARK: Open
Sep 10, 2026DOBLANDMARK: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)