Manhattan · Block 1966 · Lot 38 · 10027

467 West 125 Street

3 floors · 4 apartments · 3,750 sq ft · built 1925 · class S4 · owner of record: Great Harmony Realty Corp

32open violations
$31,220ECB/OATH penalties owed
6HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 45 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-08-12 (Accepted). Agency page

Dec 31, 2026
in 45 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual

Open violations

ECB / OATH (3) · $31,220 owed
IssuedViolationHearingBalance
May 28, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED MASONRY WALL CHIMNEY HAS COLLAPSED EARLIER AND IT IS IN DANGER AS VIOLATION #39138584H ISSUED ON 02-14-2025 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER., REPAIR AND/
#39190198H
Aug 6, 2026
DEFAULT
$25,000
Feb 14, 2025Construction CLASS - 1
SECTION OF MASONRY WALL CHIMNEY HAS COLLAPSED INTO APARTMENT WITH SECTION OF MASONRY STILL HANGING AND IN DANGER OF COLLAPSE., REPAIR AND/REPLACE; VACATE APT 2F,3F AND 1ST FLOOR COMMERCIAL SPACE.
#39138584H
Sep 22, 2026
IN VIOLATION
$6,220
Mar 1, 2021Boilers CLASS - 2
FLUE PIPING BACK PITCHED-BOILER ROOM NOT FIRE RATED-BACK FLOW LEAKING-CORROSION ON HW PIPING-COMBUSTIBLE MATERIAL IN BOILER ROOM AND STORAGE CLUTTERING BOILER ROOM.
#39036854L
Aug 19, 2021
IN VIOLATION
$0
DOB (8)
IssuedViolationStatus
Mar 24, 2025CONSTRUCTION
FAILURE TO MAINTAIN.AT TIME OF INSPECTION,OBSRVD INACTIVE CHIMNEY@EXP4 LOT FIRE PRTLLY CLLPSD@2NDFL CHIMNEY ABOVE IS IMPROPERLY SUPPORTD IN DANGER OF CLLPSE.OBSRVD 1STFL CHIMNEY.COMPLY WITH COMMISSIONER'S ORDER :DOB VIOLATION #021425FEU10902AK (CONTROL 341925) IMMEDIATELY
#FEU10901AK
DOB VIOLATION - ACTIVE
Feb 14, 2025CONSTRUCTION
EMERGENCY WORK ORDER.AT TIME OF INSPCTN,OBSRVD INACTIVE CHIMNEY@EXP4 LOT FIRE PRTLLY CLLPSD@2NDFL.CHIMNEY ABOVE IS IMPROPERLY SUPPORTD&IN DANGER OF CLLPSE.OBSRVD 1STFL CHIMNEY FIRE CHARRED.OWNR TO RTAIN NYSPE &ENDRSD CNTRCTR TO IMMED DEMO COMPROMISED CHIMNEY FROM CELLAR TO TOP OF CHIMNEY (ENTIRE CHI
#FEU10901AK
DOB VIOLATION - ACTIVE
Feb 14, 2025CONSTRUCTION
FAILURE TO MAINTAIN.AT TIME OF INSPECTION,OBSRVD INACTIVE CHIMNEY@EXP4 LOT FIRE PRTLLY CLLPSD@2NDFL CHIMNEY ABOVE IS IMPROPERLY SUPPORTD IN DANGER OF CLLPSE.OBSRVD 1STFL CHIMNEY.OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO EVAL THE ENT BLDG&RPAIR UNDR PRMT.FILE FOR RPAIR BY 3/14/25 SGN OFF RPAIRS
#FEU10902AK
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#28087
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#05561
DOB VIOLATION - ACTIVE
May 12, 1998ELECTRIC SIGNS

#B908SI
DOB VIOLATION - ACTIVE
Jan 9, 1991ELECTRIC SIGNS

#ST03W
DOB VIOLATION - ACTIVE
Jan 9, 1991ELECTRIC SIGNS

#ST04W
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 9)
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
HPD (15) · C 6 · B 2 · A 7
IssuedClassViolationCorrect by
Mar 29, 2021A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYJul 2, 2021
Mar 29, 2021A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYJul 2, 2021
Mar 29, 2021C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORYApr 4, 2021
Mar 29, 2021A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORYJul 2, 2021
Mar 29, 2021A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYJul 2, 2021
Mar 29, 2021A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.Jul 2, 2021
Mar 29, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 3rd STORYMay 3, 2021
Mar 29, 2021A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3rd STORYJul 2, 2021
Mar 29, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT PUBLIC HALL, 3rd STORYMay 3, 2021
Mar 29, 2021A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORYJul 2, 2021
Nov 5, 2020CApt 3RN · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3RN, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTDec 1, 2020
Nov 5, 2020CApt 3RN · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 3RN, 3rd STORYNov 29, 2020
Nov 5, 2020CApt 3RN · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3RN, 3rd STORY, 1st APARTMENT FROM Nov 29, 2020
Nov 5, 2020CApt 3RN · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3RN, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTDec 1, 2020
Nov 2, 2020CApt 3RN · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE FOYER LOCATED AT APT 3RN, 3rd STORY, 1stNov 26, 2020

Check the agency records