4 floors · 7 apartments · 5,023 sq ft · built 1910 · class C1 · owner of record: 467 Entities Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 52 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 52 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 68 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 296 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 783 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 19, 2024 | Construction CLASS - 1 OBSERVED CONSTRUCTION ACTIVITY, HUGE HOLE IN FLOOR LOCATED ON THE FIRST FLOOR IN THE ROOM. FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO GUARD RAILS. POTENTIAL FALL HAZA #39119548R | Dec 14, 2026 | $12,500 |
| May 9, 2024 | Construction CLASS - 2 RESPONDENT FAILED TO COMPLY WITH THE COMMISSIONERS ORDER TO CORRECT THE VIOLATING CONDITION(S) AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-204.2 FOR NOV#39526342J ISSUED ON 03/12/2024 #39528466K | May 17, 2027 | $3,125 |
| Apr 15, 2024 | Construction CLASS - 2 ? AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A 6 STORY BUILDING, ACCESS TO JOBSITE WAS DENIED BY WORKERS ON THIS DAY 04/15/2024, JOBSITE RUNS UNDER PERMIT#.B00679711, PHONE CALLS. WERE MADE TO GC. FOR WORKER #39111690L | Jan 28, 2027 | $5,000 |
| Apr 15, 2024 | Construction CLASS - 1 AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A # 6 STORY NB, OBSERVED WORKERS ON A LEADING EDGE AT #4,STORY WORKING WITHOUT FALL PROTECTION IN PLACE, WORKERS WERE NOT WEARING HARNESS TO PERFORMED DUTIES. STOP #39111692P | Apr 19, 2027 | $10,000 |
| Mar 12, 2024 | Construction CLASS - 2 AT TIME OF MY INSPECTION OBSERVED: STYROFOAM RESIDUES, DEBRIS THROUGHOUT THE REAR YARD CREATING A POTENTIAL SAFETY AND HEALTH HAZARDOUS CONDITION FOR OCCUPANTS OF ADJACENT PROPERTY. STOP ALL EXTERIOR WORK AT EX #39526340X | Dec 14, 2026 | $10,000 |
| Mar 12, 2024 | Unknown CLASS - 1 RESPONDING A COMPLAINT OBSERVED: CONTRACTOR FAILURE TO PROVIDE ROOF PROTECTION FOR ADJACENT OCCUPIED BUILDING AT EXPOSURE# 2 CONTRARY TO BC 3309.10, CREATING A POTENTIAL SAFETY HAZARDOUS CONDITION, MATERIALS TO #39526342J | Dec 14, 2026 | $5,000 |
| Mar 12, 2024 | Unknown CLASS - 2 3314.4.8 MAINTENANCE. RESPONDING A COMPLAINT OBSERVED: SUPPORTED SCAFFOLD FAILURE TO MAINTAIN LOOSE NETTING DEBRIS THROUGHOUT SITE AT EXPO# 3-2, CREATING UN UNSAFE CONDITION, TOOLS DEBRIS COULD FELL OFF AND SER #39526343L | Dec 14, 2026 | $5,000 |
| Mar 12, 2024 | Construction CLASS - 2 RESPONDING A COMPLAINT OBSERVED: CONTRACTOR FAILURE TO PROVIDE OVER HEAD PROTECTION FOR ADJACENT OCCUPIED BUILDING AT REAR YARD EXPOSURE# 2, CREATING A POTENTIAL SAFETY HAZARDOUS CONDITION, MATERIALS TOOLS CAN #39526341H | Dec 14, 2026 | $5,000 |
| Apr 5, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION I OBSERVED PROPERTY BUILDING FULLY DEMOLISHED AT GRADE LEVEL. UPON REVIEW DEPARTMENT OF RECORDS NO DEMOLITION PERMIT WAS OBTAIN.STOP ALL CONSTRUCTION OPERATIONS ON SITE. #39514988K | Mar 3, 2027 | $12,500 |
| Dec 16, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS.AT TIME OF INSPECTION OF ACTIVE JOB SITE WITH ABATEMENT OPERATIONS OBSERVED HOUSEKEEPING ON 1ST FL NOT MAINTAINED AS REQUIRED ELECTRICAL CABLED #39510481N | Sep 19, 2024 IN VIOLATION | $2,500 |
| Dec 15, 2022 | Construction CLASS - 1 AT THE TIME OF MONITORING A 3 STORY WOOD FRAMED AND MASONRY BUILDING UNDER FULL DEMOLITION , I OBSERVED THAT THE ONLY MEANS OF EGRESS / INGRESS WAS OBSTRUCTED AND NOT ADEQUATELY MAINTAINED AS VREQUIRED.PROVIDE #39510414N | Mar 18, 2027 | $1,250 |
| Dec 15, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING , DEBRIS CONSISTING OF STEEL ROD'S, WOOD , ELECTRIC CABLES CARDBOARD ALONG WITH PAPER WERE OBSERVED AT 1ST FLOOR LEVEL WHILE WORKERS WERE OBSERVED WORKING ON THAT FLOOR #39510429X | Apr 16, 2024 IN VIOLATION | $2,500 |
| Nov 16, 2022 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED APPROX. 7'-0" DEPTH EXCAVATION DONE ON REAR YARD TO BUILD FOUNDATION WALL FOR BUILDING EXTENSION. EXCAVATION DONE INADEQUATE MANNER WITHOUT PROVIDING ANY PROTECTION AT SIDE OF EXC #39074006X | Mar 29, 2027 | $12,500 |
| Nov 16, 2022 | Construction CLASS - 1 FAILURE TO MAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED REMOVED ENTIRE ROOF, PARTITION WALL & CELLAR FLOOR LOWERING DOWN, UNDER PINNING ADJACENT PARTY WALLS WITHOUT ANY PROTECTION. PARTY WALL FREE STANDING #39074005Y | Mar 29, 2027 | $3,125 |
| Issued | Violation | Status |
|---|---|---|
| Nov 16, 2022 | IMMEDIATE EMERGENCY BACKFILL THE ENTIRE CELLAR APPROXIMATELY 2FEET DEEP UP TO TOP OF EXISTING SLAB TO RESTORE BEARING AND BRACING AT BOTTOM OF PARTY WALLS #17 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 7, 2026 | A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSING | Aug 10, 2026 |
| May 7, 2026 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Aug 10, 2026 |
| May 7, 2026 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Aug 10, 2026 |
| May 7, 2026 | A | §27-2045(B)(5) HMC, § 12-01 RCNY POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAILBOX MISSING | Aug 10, 2026 |
| May 7, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY | Jun 11, 2026 |
| May 7, 2026 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 2nd STORY | Jun 11, 2026 |
| May 7, 2026 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT MISSING AT PUBLIC HALL, 1st STORY | Aug 10, 2026 |
| May 7, 2026 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Aug 10, 2026 |
| May 14, 2025 | A | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE GARBAGE AT FRONT AREAWAY | Aug 17, 2025 |
| Apr 21, 2025 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | May 17, 2025 |
| Apr 21, 2025 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF ,WASHING MACHINE AND DRYER AT PUBLIC HALL, 3rd STORY | May 26, 2025 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)