4 floors · 8 apartments · 6,000 sq ft · built 1931 · class C1 · owner of record: Pulaski 464 Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-13 (Accepted). Agency page | Dec 31, 2026 in 65 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 8, 2014 | Construction CLASS - 1 WORK W/O A PERMIT NOTED: AT SECOND FLOOR LEVEL RIGHT SIDE APARTMENT INSTALLATION OF PARTITIONS ENCLOSING FRONT AND REAR ENTRY DOOR. AT MAIN HALL AND CREATING OPENING AND DOORWAY AT CENTER.RMDY:STOP ALL WORK MAK #35090623X | Jun 16, 2014 WRITTEN OFF | $0 |
| Feb 8, 2014 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED AT MAIN HALL SECOND LEVEL OBSTRUCTED W/EXCESSIVE CONSTRUCTION DEBRIS AND MATERIALS THROUGHOUT. #35090624H | Jun 18, 2014 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 3, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT #12434 | DOB VIOLATION - ACTIVE |
| May 7, 2014 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00119 | DOB VIOLATION - ACTIVE |
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #22452 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #38693 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Mar 3, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT | Active |
| May 7, 2014 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 18, 2024 | B | Apt 1L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 22, 2024 |
| Mar 18, 2024 | B | Apt 1L · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 22, 2024 |
| Dec 27, 2022 | B | Apt 1L · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 31, 2023 |
| Dec 27, 2022 | B | Apt 1L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 31, 2023 |
| Jul 29, 2022 | B | Apt 2R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL FRAME AT 1ST WINDOW FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 2, 2022 |
| Jul 29, 2022 | B | Apt 2R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT INSTALLED AT FIRE EASCAPE WINDOW OBSTRUCTING EGRESS IN THE 1st ROOM FROM NORTH LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 2, 2022 |
| Jul 27, 2022 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 22, 2022 |
| Aug 16, 2021 | C | Apt 3L · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 1; IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APA | Sep 11, 2021 |
| Dec 12, 2016 | B | Apt 3L · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL / BUZZER SYSYEM ON WEST WALL IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, APARTMENT AT EAST | Jan 16, 2017 |
| Jun 9, 1998 | C | Apt 2L · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT 2 RISERS RADIATOR AND DOOR WAY CASING BATHROOM 2 STY EAST APT 2L ER1 1736. , SECTION '' '' | Jun 29, 1998 |
| Jun 9, 1998 | C | Apt 2L · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT DOOR WAY CASING 2 RISERS AND RADIATOR REAR ROOM 2 STY EAST APT 2L ER1 1736. , SECTION '' '' | Jun 29, 1998 |
| Jun 9, 1998 | C | Apt 2L · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT RADIATOR AND 2 RISERS AND 2 WINDOW CASINGS FRONT ROOM 2 STY EAST APT 2L ER1 1736. , SECTION '' '' | Jun 29, 1998 |
| Jun 9, 1998 | C | Apt 2L · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT 2 STEAM RISERS HOT AND COLD WATER RISERS AND TIN CEILING KITCHEN 2 STY EAST APT 2L HERMAN 574 0172 ER1 1736. , SECTION '' '' | Jun 29, 1998 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 4:22 AM ET. BBL 3015990027.