1 floors · 28,350 sq ft · built 1950 · class E1 · owner of record: Pac Realty Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 28,350 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 410 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 2, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION NOTED NO CERTIFICATE OF CORRECTION ON FILE FOR ECB VIOLATION NUMBER 35 #39046898M | Dec 3, 2021 IN VIOLATION | $0 |
| Apr 24, 2018 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG DEPT RECORDS.NOTE: AT TIME OF INSPECTION OBSERVED 1ST STY OF BLDG NORTH SECTION UTALIZED AS A AUTO MECHANIC SHOP CONTRARY TO USE &OCCUPANCY ALLOWED ON #35250341H | Jul 6, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 20, 2015 | CONSTRUCTION FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.BLDG IS WAREHOUSE TYPE STRUCTURE WITH W/BOWSTRING TRUSS-ROOF.DEPARTMENT SERVED A CURABLE COMMISSIONER'S ORDER ON 1/22/15 TO PROVIDE AN ENGINEER REPORT ON YOUR BUILDING.NO ENGINEER'S REPORT HAS BEEN RECEIVED. COMPLY PER THE COMMISSIONER'S ORDER #FEU21205JH | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | HIGH PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE 2013 ANNUAL HIGH PRESSURE BOILER INSPECTION #00463 | DOB VIOLATION - ACTIVE |
| Jan 22, 2015 | CONSTRUCTION NYC ADMIN CODE.1STORY OCCUPIED COMMERICAL BLDG. WITH WOOD BOWSTRING TRUSS ROOF. OWNER TO ENGAGE NYS LICENSED PE EXPERINCED WITH WOOD TRUSSES TO PROBE & EVALUATE STRUCTURAL SOUNDNESS OF BOWSTRING USING FIELD,VERIFICATION,CALCULATION, PROBES.EACH TRUSS & BEARING TO BE EVALUATED.REPAIR DWGS TO BE FILED #FEU21202JH | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Mar 3, 2015 | Boiler HBLVIO VIOLATION ISSUED FOR FAILURE TO FILE 2013 ANNUAL HIGH PRESSURE BOILER INSPECTION | Active |
None open.