6 floors · 29 apartments · 32,342 sq ft · built 1920 · class D1 · owner of record: West 128th Street L.P.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 32,342 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 781 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-07 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A AND 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #813659. AGG1: PRIOR NOV 37026206L UNDER #37036507Y | Jul 16, 2026 DEFAULT | $10,000 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A AND 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #813659. REMEDY: FILE ACCEPTABLE REPORT. #37026206L | Aug 13, 2024 DEFAULT | $374 |
| Dec 2, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#913659. REMEDY:SUBMIT ACCEPTABLE REQUIR #37024384P | Oct 12, 2023 DEFAULT | $6,250 |
| Nov 3, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG NORTH ELEV EXP 1.OBJECTS ON FIRE ESCAPE A/C UNIT 4TH FL BOARD ON FIRE ESCAPE 4TH FL.NORTHWEST CORNER-CORNER-UNDER/BELOW BRICK WORK DEFECTIVE MORTAR DEFECTIVE-TRANSITIONAL STONE #35174000H | Dec 22, 2016 IN VIOLATION | $0 |
| Aug 11, 2016 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4. AGG2 HISTORY OF NONCOMPLIANCE ON 36027941X(AGG1),36019043Y. #37001066H | Dec 29, 2016 IN VIOLATION | $0 |
| Apr 25, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG ROOF NORTH ELEV. EXP.1 BOILER CHIMNEY CRACKED PARAPET STUCCO BULDING & VERTICLE CRACKS EAST ELEV 2 - VERTICLE CRACK IN NORTH / EAST CORNER IN TRANSITIONAL MASONRY SOUTH ELEV. E #35174276Z | Aug 11, 2016 DEFAULT | $0 |
| Nov 14, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING.AS NOED: AT TIME OF INSPECTION OBSERVED AT EXP#4, 7TH FLR DETERIORATED BRICK/JOINTS AND PEELING WATERPROOFING. AND FILE REPORT AS PER 1RCNY 103-04. RMDY: MAINTAIN EXTERIOR #35160145L | Dec 31, 2015 STIPULATION/IN-VIO | $0 |
| Oct 8, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG 6 FL TRANSITIONAL CORNER.(NW CORNER)BRICK TO STONE TRIM-MASONRY TRIM DISLODGED MISSING MORTAR.WEST ELEV EXP4-SPALLING BRICK-MISSING MORTAR CONTAINERS ON 5FL WINDOW SILL.IMMEDIA #35133736J | Dec 17, 2015 STIPULATION/IN-VIO | $0 |
| Sep 29, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES NOTED: AT EXP4, CEMENT PLASTER/STUCCO IS SPALLING NEAR PARAPET WALL. RMDY: MAINTAIN EXTERIOR WALL. #35160868P | Nov 19, 2015 STIPULATION/IN-VIO | $0 |
| Sep 15, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS:36019043Y:PERIODIC INSP OF EXTERIOR WALLS & APPUTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DOB RULES & REGULATIONS.REM:FILE THE R #36027941X | May 5, 2016 IN VIOLATION | $0 |
| Apr 28, 2014 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28-302 & THE DEPT OF BLDGS RULES & REGULAT #36019043Y | Sep 4, 2014 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 12, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED ON EXP 1 NORTH ELEVATION - BULGING MASONRY ON 6TH FLOOR NORTH WEST CORNER OF BLDG. EXP 4 WEST ELEVATION SPALLING STUCCO 6TH FLOOR AT NORTH WEST AND SOUTH WEST END OF EXPOSURE. REMEDY: REPAIR AND/OR REPLACE ALL DAMAG #SR1002RF | DOB VIOLATION - ACTIVE |
| Mar 21, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE AT TIME O F INSPECTION,OBSERVED MULTIPLE AREAS OF CRACKED STUCCO AT EXP4 AT VARI OUS LEVELS OF FACADE.REMEDY:REPAIR AND/OR REPLACE #SR11003DO | DOB VIOLATION - ACTIVE |
| Oct 2, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION IT WAS OBSERVED AT EXPOSURE 4 (W. ELEV) (2) ARES OF SPALLING STUCCO. REMEDY: REPAIR AND/OR REPLACE #SR11002MA | DOB VIOLATION - ACTIVE |
| May 16, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT THE TIME OF INSPECTION OBSERVED 2 AREAS OF SPALLING STUCCO ON EXPOSURE #4 REMEDY: REPAIR AND/OR REPLACE #SR11001DO | DOB VIOLATION - ACTIVE |
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #01706 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #02113 | DOB VIOLATION - ACTIVE |
| Dec 14, 2016 | FACADE SAFETY PROGRAM #HAZ86342 | DOB VIOLATION - ACTIVE |
| Dec 14, 2016 | FACADE SAFETY PROGRAM #HAZ76343 | DOB VIOLATION - ACTIVE |
| Jan 31, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012 #00770 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01486 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Jan 31, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 1, 2026 | C | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCKSET AT BUILDING ENTRANCE DOOR , 1st STORY | Jun 7, 2026 |
| Jun 1, 2026 | B | Apt 2D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 6, 2026 |
| Jun 1, 2026 | B | Apt 2D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 6, 2026 |
| Jun 1, 2026 | C | Apt 2D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 27, 2026 |
| Jun 1, 2026 | B | Apt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR TILES IN THE PRIVATE HALLWAY LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 6, 2026 |
| May 12, 2026 | B | Apt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY | Jun 16, 2026 |
| May 12, 2026 | B | Apt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2D, 2nd STORY | Jun 16, 2026 |
| May 8, 2026 | A | Apt 3B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE KITCHEN , THE 1st ROOM FROM NORTH AT EAST, THE 1st ROOM FROM NORTH AT WEST, THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST | Aug 11, 2026 |
| May 5, 2026 | B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Jun 9, 2026 |
| May 5, 2026 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE LOOSE GARBAGE AT BASEMENT | Jun 9, 2026 |
| May 4, 2026 | B | Apt 6E · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | B | Apt 6E · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 8, 2026 |
| May 4, 2026 | C | Apt 3B · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APA | May 30, 2026 |
| Oct 17, 2025 | B | Apt 2E · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE WASH BASIN IN THE BATHROOM LOCATED AT APT 2E, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Nov 21, 2025 |
| Sep 29, 2025 | C | Apt 2B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 25, 2025 |
| Sep 29, 2025 | B | Apt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 3, 2025 |
| Sep 29, 2025 | C | Apt 2B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 5, 2025 |
| Aug 4, 2025 | C | Apt 2D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Aug 30, 2025 |
| Aug 4, 2025 | C | Apt 2D · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Aug 30, 2025 |
| Aug 4, 2025 | B | Apt 2B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 8, 2025 |
| Aug 4, 2025 | B | Apt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 8, 2025 |
| Feb 12, 2025 | B | Apt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING OF 2ND WINDOW FROM NORTH AT EAST IN THE 4th ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17344773 ISSUED 13-OCT-24 HAS BEEN UP | Mar 19, 2025 |
| Feb 12, 2025 | B | Apt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 17344772 ISSUED 13-OCT-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE | Mar 19, 2025 |
| Oct 15, 2024 | C | Apt 6A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 21, 2024 |
| Jul 18, 2024 | B | Apt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... EAST WALL ABOVE 2ND WINDOW FROM NORTH APPROX 5 SQ-FT IN THE 3rd ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16753192 ISSUED 18-MAR-24 HAS BEEN UPGRADED TO CLASS | Aug 22, 2024 |
| Jun 16, 2023 | B | Apt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 1 SQUARE FEET OF MOLD AT SOUTH WALL, 1 SQUARE FT OF MOLD AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6A, 6th STORY ORIGINAL VIOLATION 15728336 ISSUED 14-FEB-23 HAS BEEN UPGRADED TO CLASS B PER ADMIN | Jul 21, 2023 |
| Jan 18, 2022 | B | Apt 6A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 8 SQ FT AT THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14551415 ISSUED 15-SEP-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27- | Feb 22, 2022 |
| Aug 11, 2021 | C | Apt 3B · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORT | Sep 6, 2021 |
| Nov 26, 2019 | B | Apt 6E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL, 2nd WINDOW FRAME FROM NORTH AT EAST WALL IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 31, 2019 |
| Nov 26, 2019 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL, EAST WALL, 2nd WINDOW FRAME FROM NORTH AT EAST WALL IN THE KITCHEN LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 31, 2019 |
| Nov 14, 2019 | B | Apt 6E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6E, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 19, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)