Brooklyn · Block 216 · Lot 31 · 11201

46 Henry Street

4 floors · 6 apartments · 4,000 sq ft · built 1879 · class S5 · owner of record: 46 Henry Eq Llc

13open violations
$3,750ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1164 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-14 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2) · $3,750 owed
IssuedViolationHearingBalance
Aug 27, 2025Construction CLASS - 1
OCCUPANCY HAS BEEN CREATED, WHERE A COMBUSTIBLE DECK HAS BEEN ERECTED ON 4TH. FL. ROOF OF A MULTIPLE DWELLING WITHOUT ADEQUATE GUARD RAILING FOR FALL PROTECTION CREATING AN UNSAFE ENVIROMENT., DISCONTINUE ILLEG
#39158583Y
May 21, 2026
IN VIOLATION
$2,500
Aug 26, 2025Construction CLASS - 1
PSWO ISSUED FOR WW/OP. APRX 20 X 13 FT & 2 FT HIGH COMBUSTIBLE WOODEN DECK ERECTED AT THE FRONT SIDE OF BUILDING'S ROOF. WORK IN PROGRESS TO EXTEND WOOD DECKING TO THE BACK OF THE ROOF. WORK APRX 50% COMPLETE.
#39158422N
Nov 5, 2025
IN VIOLATION
$1,250
DOB (3)
IssuedViolationStatus
Sep 10, 2025LANDMARK

#26-0225
DOB VIOLATION - ACTIVE
Aug 28, 2025IMMEDIATE EMERGENCY
REMOVE ILLEGAL WOODEN DECK AT ROOF LEVEL
#19508
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#07330
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
HPD (8) · C 1 · B 7 · A 0
IssuedClassViolationCorrect by
May 18, 2020B§ 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BUILDING ENTRANCE DOOR GLASS PANE , 1st STORYJun 22, 2020
Aug 24, 2015BApt 3R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHSep 28, 2015
Aug 24, 2015BApt 3R · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 28, 2015
Mar 24, 2009BSECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION ... AT PUBLIC HALL, 2nd STORYApr 28, 2009
May 4, 2007BApt 2F · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BALANCES UPPER AND LOWER SASH FIRE ESCAPE WINDOW FRONT ROOM 2 STY APT 2F , SECTION '' ''Jun 20, 2007
May 4, 2007BApt 2F · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER STAINED CEILING BATHROOM 2 STY APT 2F , SECTION '' ''Jun 20, 2007
May 4, 2007BApt 2F · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS KITCHEN SINK 2 STY APT 2F , SECTION '' ''Jun 20, 2007
May 4, 2007CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM CELLAR DOOR LOCKED.May 22, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 9:25 PM ET. BBL 3002160031.

Look up another building