5 floors · 29,415 sq ft · built 1861 · class O5 · owner of record: The Devlin Building,
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-28 (Accepted). Agency page | Dec 31, 2026 in 70 days | 2 of 3 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 29,415 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1166 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 14, 2026 | Unknown CLASS - 1 1. ELECTRICAL WORK WITHOUT PERMIT. NOTED APPROX. 9 OUTLET BOXES INSTALLED WITH BX CABLES AS FEED FOR ROOF DECKING WITHOUT PERMITS ON FILE., OBTAIN PERMIT #39184491X | Jun 18, 2026 DEFAULT | $12,500 |
| Apr 14, 2026 | Construction CLASS - 1 FTM BUILDING IN A CODE COMPLIANT MANNER. NOTED AT 5TH FL FTM/PROVIDE ADEQUATE STAIRCASE WITH HAND RAILS FOR ACCESS TO FIRE ESCAPE EGRESS. ADDITIONALLY, FTM LIGHTING AT 5TH FL STAIRCASE. THESE CONDITIONS PRESENT #39184492H | Jun 18, 2026 DEFAULT | $6,250 |
| Apr 14, 2026 | Construction CLASS - 1 1. FTM BUILDING IN A CODE COMPLIANT MANNER. NOTED, INADEQUATE HOUSEKEEPING IN THE CORRIDOR AND AT BASE OF STAIRCASE AT CELLAR LEVEL WITH GARBAGE, BUILDING MATERIALS, METAL SHELVING BLOCKING/MINIMIZING PASSAGE T #39184500Z | Jun 18, 2026 DEFAULT | $12,500 |
| Apr 24, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED 12'W X 12'L LEFT SIDE COBBLE STONE WALL AT REAR LEFT SIDE OF THE BUILDING HAS PARTIALLY COLLAPSED. MIDDLE SECTION I #39145913P | May 14, 2026 IN VIOLATION | $5,000 |
| Nov 16, 2023 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONERS ORDER TO FILE A CERT OF CORRECTION WITH THE DEPT OF BUILDINGS. NO C OF C ON FILE FOR ECB VIOLATION #39082805M (CLASS 1 IMMEDIATE HAZARD) ISSUED 03/31/2023 REGARDING PARTIAL #39099476L | May 20, 2024 IN VIOLATION | $0 |
| Aug 15, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN ADEQUATE HOUSE KEEPING PER SECTION REQUIREMENTS. NOTED: PREMISES 5-STORY OFFICE BUILDING. AT TIME OF INSPECTION OBSERVED CONSTRUCTION MATERIALS SHEETROCK 2"X4" WOODS AND DEMO DEBRIS STORED O #35581972K | Oct 19, 2023 DEFAULT | $3,125 |
| Mar 31, 2023 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED 12'W X 12'L LEFT SIDE COBBLE STONE WALL AT REAR LEFT SIDE OF THE BUILDING HAS PARTIALLY COLLAPSED. MIDDLE SECTION I #39082805M | Jun 8, 2023 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 29, 2009 | LANDMARK #09-1218 | DOB VIOLATION - ACTIVE |
| Jun 29, 2009 | LANDMARK #09-1219 | DOB VIOLATION - ACTIVE |
| Oct 31, 2008 | LANDMARK #09-0623 | DOB VIOLATION - ACTIVE |
| Oct 30, 2008 | ELEVATOR #9444/279900 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 9:28 AM ET. BBL 1002310030.