3 floors · 16 apartments · 10,140 sq ft · built 1900 · class C5 · owner of record: 45 Victory Llc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-01-06 (Accepted). Agency page | Dec 31, 2026 in 47 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 778 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 29, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT SOUTH ELEVATION EXP1,OBSERVED CRACKED/SPALLING WINDOW SILL AND CRACKED BRICK MASONRY AT LINTELS,PARAPET WALL,AND FACADE THROUGHOUT.AT NORTH ELEVATION EXP #35663686Z | Nov 2, 2022 IN VIOLATION | $0 |
| May 13, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.NOTE:OBSERVED@EXP1S CRACKED/SPALLING WINDOWSILL&CRACKED BRICK MASONRY@LINTELS,PARAPET&FACADE THRUOUT.EXP3N VERT CRACK IN FACADE@PARKING LOT AREA&CRACKED/SPALLING #35651370Y | Jul 6, 2022 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #24963 | DOB VIOLATION - ACTIVE |
| May 13, 2022 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO CRACKED/SPALLING WINDOWSILLS&CRACKED BRICK MASONRY AT LINTELS,PARAPETS AND FACADE THROUGH EXP#1SOUTH EAST REMEDY:IMMEDATELY TAKE AND PROVIDE SAFETY MEASURES TO SECURE&PROTECT THE PUBLIC AND INSTALL PUBLIC PROTECTION AT EXPO#1(SOUTH)&EXP#4(EAST) MAKE IMMEDIATE REPAIRS U #FA0101DS | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #14574 | DOB VIOLATION - ACTIVE |
| Jan 3, 2008 | LOCAL LAW 62/91 - BOILERS #26149 | DOB VIOLATION - ACTIVE |
| Jun 6, 2001 | CONSTRUCTION #ZSTF01YC | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #40752 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
| Jan 3, 2008 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 27, 2018 | B | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SHOWER STALL AT COMMUNITY BATHROOM, 2nd STORY | Nov 1, 2018 |
| Sep 26, 2018 | B | Apt 4 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INOPERATIVE LIGHT FIXUTRE AT CEILING IN THE WATER CLOSET COMPARTMENT LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM NORTH AT EAST | Oct 31, 2018 |
| Sep 26, 2018 | B | § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SHOWER STALL AT COMMUNITY BATHROOM, 2nd STORY | Oct 31, 2018 |
| Sep 26, 2018 | B | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT SHOWER STALL AT COMMUNITY BATHROOM, 2nd STORY | Oct 31, 2018 |
| Sep 26, 2018 | B | Apt 4 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM NORTH AT EAST | Oct 31, 2018 |
| Sep 26, 2018 | B | Apt 4 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM NORTH AT EAST | Oct 31, 2018 |
| Apr 7, 2017 | B | Apt 4 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM WEST AT NORTH | May 12, 2017 |
| Apr 7, 2017 | B | Apt 4 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS DEFECTIVE LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM WEST AT NORTH | May 12, 2017 |
| Apr 7, 2017 | B | Apt 4 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). WHICH IS DEFCTIVE LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM WEST AT NORTH | May 12, 2017 |
| Dec 5, 2016 | B | Apt 4 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE ROOM LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM NORTH AT EAST | Jan 9, 2017 |
| Sep 9, 2016 | B | Apt 4 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF BEDBUGS LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM SOUTH AT WEST | Oct 14, 2016 |
| Sep 9, 2016 | B | Apt 4 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM SOUTH AT WEST | Oct 14, 2016 |
| Sep 9, 2016 | B | Apt 4 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM SOUTH AT WEST | Oct 14, 2016 |
| Sep 19, 2012 | B | Apt 3 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR IN THE ROOM LOCATED AT B-ROOM 3, 2nd STORY, 1st B-ROOM FROM EAST AT SOUTH | Oct 24, 2012 |
| Sep 19, 2012 | B | Apt 3 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR JAMBS IN THE ROOM LOCATED AT B-ROOM 3, 2nd STORY, 1st B-ROOM FROM EAST AT SOUTH | Oct 24, 2012 |
| Sep 19, 2012 | B | Apt 4 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS THROUGHOUT IN THE ROOM LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM NORTH AT EAST | Oct 24, 2012 |
| Mar 11, 2010 | B | Apt 4 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING LOCATED AT B-ROOM 4, 2nd STORY, 4th B-ROOM FROM NORTH AT EAST | Apr 15, 2010 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 5:59 AM ET. BBL 5000160142.