2 floors · 2 apartments · 3,300 sq ft · built 1910 · class B2 · owner of record: 45 Pine Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 315 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 3, 2026 | Construction CLASS - 1 ATOI OBSERVED UNKNOWN MALE WORKING INSIDE THE PROPERTY, UNDER FVO. NO ONE IS ALLOWED INSIDE THE PROPERTY. FVO ISSUED DATED 12/22/2025 COMPLAINT # 3A42486 DUE TO FIRE, ROOF IS COMPROMISED. ECB VIOLATION WAS ISSU #39203068J | Nov 18, 2026 PENDING | $25,000 |
| Mar 31, 2026 | Construction CLASS - 1 ATOI, 03/30/2026, ACTIVE CONSTRUCTION AT PREMISES UNDER FULL VACATE DUE TO FIRE. WORKERS MASKING EXCESSIVE CHARRING/WARPED WOOD FRAMING, JOISTS & FLOORING WITH NEW SISTERING, TEMP SHORING & SHEETROCK. WORK DONE #39182715R | Jun 24, 2026 DEFAULT | $25,000 |
| Mar 30, 2026 | Unknown CLASS - 1 OBSERVED ACTIVE ELECTRICAL WORK WITHOUT PERMITS THROUGHOUT PREMISES. NEWLY INSTALLED BX CABLES, SWITCHES, OUTLETS, AND TEMPORARY LIGHTING OBSERVED ON ALL LEVELS. OBSERVED THREE ELECTRICAL PANELS WITH COVERS REM #39182525X | Jan 21, 2027 PENDING | $2,500 |
| Mar 30, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN PREMISES IN CODE COMPLIANT MANNER. EXCESSIVE FIRE DEBRIS/CHARRED ELEMENTS STACKED AT EXP 1 & 4, BLOCKING BASEMENT EGRESS. EXPOSED ELECTRICAL PANELS ON ALL 3 LEVELS. 2ND FL MISSING HANDRAILS/ #39182526H | Jan 21, 2027 PENDING | $2,500 |
| Mar 30, 2026 | Construction CLASS - 1 OBSERVED CONSTRUCTION WORK WITHOUT PERMITS ON 1ST AND 2ND FLOOR LEVELS. NEW SHEETROCK INSTALLED THROUGHOUT PREMISES TO MASK EXCESSIVE CHARRING AND FIRE-DAMAGE TO STRUCTURAL ELEMENTS. OBSERVED TEMPORARY SHORING, #39182524Y | Jan 21, 2027 PENDING | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Apr 20, 2026 | CONSTRUCTION AT TIME OF INSPECTION OBSERVED VIOLATING UNDER VIOLATION 39182524Y ISSUED ON 3/30/2026 REQUIRED IN ENGINEERING REPORT FOR STRUCTURALLY CHARRED SUPPORT MEMBERS REMAINING IN PLACE AND MIGHT HAVE CAUSE STRUCTURAL STABILITY ISSUES TO THE ADJACENT PROPERTIES. #26-01094 | DOB VIOLATION - ACTIVE |
| Dec 23, 2025 | IMMEDIATE EMERGENCY SEAL ALL FIRE DAMAGED OPENINGS TO SAFEGUARD THE PUBLIC AND PROPERTY AND PREVENT #19850 | DOB VIOLATION - ACTIVE |
| Dec 23, 2025 | CONSTRUCTION EMERGENCY WORK.RESIDENTIAL BLDG THAT SUSTAIND SEVERE DAMAGE DUE TO FIRE ON 12/22/25.REAR WALL PRTLLY CLLPSD 2ND&3RD FL JOISTS@REAR SEVERELY CHARRED AND COMPROMISED.IMMED DO 1.DEMO REAR WALL,2.PRVDE TEMP SHORNG FRM CELLAR TO ROOF@REAR,3.INSTLL TEMP WTHRPRF WALL@REAR ALL WRK TO BE PRFRM #FEU30501XC | DOB VIOLATION - ACTIVE |
| Dec 23, 2025 | CONSTRUCTION FAILURE TO MAINTAIN.BLDG WAS DMGD BY FIRE ON 12/22/25.SEVERE DAMAGE@ REAR.WATER DAMAGE&COLLAPSED CEILINGS&FINISHES THROUGHOUT.REAR WALL PARTIALLY COLLAPSED 2ND&3RD FLOOR DAMAGED.BLDG AND REPAIR UNDER PERMIT BY 2/2/2026,SIGN OFF BY 4/1/2025 #FEU30502XC | DOB VIOLATION - ACTIVE |
| Dec 22, 2025 | CONSTRUCTION STRUCTURE RENDERED NON COMPLIANT DUE TO EXTENSIVE FIRE DAMAGE OPEN ROOF CHARRED WOOD JOIST LEAVING EXP# 3 REAR OF PROPERTY OPEN TO THE ELEMENTS #25-03296 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 28, 2024 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Oct 29, 2024 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 24, 2024 |
| Oct 28, 2024 | C | Apt 2 · § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 26, 2024 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 3, 2026 | ECB | Construction: ATOI OBSERVED UNKNOWN MALE WORKING INSIDE THE PROPERTY, UNDER FVO. NO ONE IS ALLOWED INSIDE THE PROPERTY. FVO ISSUED DATED 12/22/2025 COMPLAINT # 3A42486 DUE TO FIRE, ROOF IS COMPROMISED. ECB VIOLATION WAS ISSU | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 21, 2026, 11:05 PM ET. BBL 3041180001.