4 floors · 9 apartments · 20,000 sq ft · built 1900 · class HH · owner of record: 39 Ainslie Property Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 791 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 8, 2026 | Elevators CLASS - 2 CLASS 2: 1. EMERGENCY PHONE INOPERATIVE, AS PER ASME A17.1 2.27.1.1.6. REMEDY: REPAIR EMERGENCY PHONE AND RESTORE PROPER TWO-WAY COMMUNICATION. 2. TOP-OF-CAR LIGHT INOPERATIVE, AS PER ASME A17.1 2.14.7. REMEDY: #39207287H | Dec 16, 2026 PENDING | $625 |
| Oct 8, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED A WATER HEATER ON THE FIRST FLOOR INSTALLED WITH PVC BEING USED ON THE INTAKE PIPING THIS IS CONTRARY TO 503.4.1, REPAIR AND/OR REPLACE #39207331X | Dec 16, 2026 PENDING | $1,250 |
| Oct 8, 2026 | Construction CLASS - 2 ATOI OBSERVED LACK OF SPRINKLER COVERAGE IN LAUNDRY ROOM 3 DRIERS WERE IN OPERATION WITH ON 1 SPRINKLER HEADS 2+ DRIERS REQUIRE 2 HEADS CONTRARY TO . BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER #39207330Y | Dec 16, 2026 PENDING | $1,250 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 8, 2026 | ECB | Elevators: CLASS 2: 1. EMERGENCY PHONE INOPERATIVE, AS PER ASME A17.1 2.27.1.1.6. REMEDY: REPAIR EMERGENCY PHONE AND RESTORE PROPER TWO-WAY COMMUNICATION. 2. TOP-OF-CAR LIGHT INOPERATIVE, AS PER ASME A17.1 2.14.7. REMEDY: | Open |
| Oct 8, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED A WATER HEATER ON THE FIRST FLOOR INSTALLED WITH PVC BEING USED ON THE INTAKE PIPING THIS IS CONTRARY TO 503.4.1, REPAIR AND/OR REPLACE | Open |
| Oct 8, 2026 | ECB | Construction: ATOI OBSERVED LACK OF SPRINKLER COVERAGE IN LAUNDRY ROOM 3 DRIERS WERE IN OPERATION WITH ON 1 SPRINKLER HEADS 2+ DRIERS REQUIRE 2 HEADS CONTRARY TO . BC 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 1:10 PM ET. BBL 3023710048.