4 floors · 75,050 sq ft · built 1931 · class F1 · owner of record: Zdj Vernon Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy audit and retro-commissioning (2026) Likely applies Local Law 87 · Calendar year 2026 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 26). Agency page | Dec 31, 2026 in 66 days | Due this year |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 75,050 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 18, 2026 | Construction CLASS - 2 (5:00AM) AT TIME OF INSPECTION OF THE SIDEWALK SHED AT EXP 1 AND 2 OF A 22 STORY MIXED USED BUILDING THE UNDERSIDE LIGHTS ARE LUMINATING AS REQUIRED TO CODE AT EXP 1 HOWEVER THERE IS NO UNDERSIDE LIGHTING AT EX #39558044H | Oct 27, 2026 PENDING | $2,400 |
| May 27, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE, 22 STORY BUILDING SUPER STRUCTURAL COMPLETED TO BULKHEAD. OBSERVED AT 1ST, #35729975Y | Mar 16, 2027 | $1,250 |
| Oct 3, 2025 | Unknown CLASS - 1 BC 3301.6.1 OBSERVED SCISSOR LIFTS IMPROPERLY IN USE, WORKERS WERE NOT CERTIFIED TO USE LIFT AND WEREN'T TIED OFF TO PROPER ANCHORAGE POINTS, THIS CREATES UNSAFE CONDITIONS FOR USERS AND OTHERS BY NOT BEING PRO #39545610K | Jul 7, 2026 IN VIOLATION | $2,500 |
| Sep 13, 2025 | Unknown CLASS - 1 BC 3303.3 WATCH PERSON. 22-STORY NB AT 19 FL. DECK, 19514 SQ. FT. APPROX. SITE CLOSED AND THERE WAS NO CONSTRUCTION ACTIVITY. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE TO ALERT WATCHPERSON AND TO VERIFY C #39544840L | Jan 5, 2027 | $5,000 |
| Jun 25, 2025 | Unknown CLASS - 1 BC 3308.6 AT TIME OF INSPECTION PROPOSED 22 STORIES NB AT 7 FLOORS WITH ONGOING FORMWORK AND STRIPPING AT 7 FLOOR NO HORIZONTAL NETTING INSTALLED AS PER CODE BC 3308.6. STOP ALL CONCRETE FORM WORK AND STRIPPI #39541700X | Oct 6, 2026 IN VIOLATION | $5,000 |
| Feb 7, 2025 | Construction CLASS - 1 SOE102.00 DETAIL A1+FO102.00 DETAIL 2@ACTIVE 22STORY ENLARGEMENT SITE IN EXCAVATION&FOUNDATION PHASE OBSERVE FORMWORK FOR CONCRETE GRADE BEAM&FOOTING WITH STEEL REINFORCEMENT(REBAR)WITH NO STAYFORM IN PLACE TO #39536763R | Dec 22, 2026 | $2,500 |
| Sep 25, 2024 | Unknown CLASS - 1 3310.4 SITE SAFETY MONITORING PROGRAM: A PROPOSED 22 STORY BUILDING UNDER DEMO, I REQUESTED SITE SAFETY PERSONAL, SITE SAFETY PLAN AND THE LOGS. MECHANICAL DEMO REQUIRES A DESIGNATED SITE SAFETY PERSONAL AND A #39532768H | Feb 10, 2026 IN VIOLATION | $5,000 |
| Sep 24, 2013 | Elevators CLASS - 2 97##5-FAILURE TO MAINTAIN ELEFVATOR DEVICE RESPONDENT FAILED TO ALLOW MANDATORY ANNUAL/ROUTING INSPECTION BY THE DEPARTMENT OR APPROVED AGENCY FOR 28-304.6.1 AND APENDIX K OF THE BUILDING CODE.MULTIPLE ATTEMPTS #38228522P | Jan 14, 2014 WRITTEN OFF | $0 |
| Oct 31, 2009 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES NOTED AT FRONT OF PREMISES PARAPET WALL HAS STEP CRACKS WALL BULGING AT THE PLUMB APPROX 2"INCHES WINDOW LINTELS RUSTED ROTTEN REM: PROVIDE ENGINEERS REPORT INSTA #34818701P | Jun 1, 2010 WRITTEN OFF | $0 |
| Oct 15, 2009 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTED: AT TIME OFINSPECTION,THE FOLLOWING CONDITIONS OBSERVED. BULGING BRICK AT 3RD FLRLEVEL IN VARIOUS LOCATIONS(FRONT). BOWED/ROTTED/DEFECTIVE LINTELS THRU #34800754N | May 17, 2011 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2021 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020) #00834 | DOB VIOLATION - ACTIVE |
| Jun 29, 2020 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2019) #00692 | DOB VIOLATION - ACTIVE |
| Mar 27, 2018 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2017) #00088 | DOB VIOLATION - ACTIVE |
| Feb 16, 2017 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2016 #00230 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | ELEVATOR #9027/535101 | DOB VIOLATION - ACTIVE |
| Mar 3, 2015 | ELEVATOR #9027/535100 | DOB VIOLATION - ACTIVE |
| Dec 16, 2013 | ELEVATOR #9027/496261 | DOB VIOLATION - ACTIVE |
| Nov 14, 2011 | CONSTRUCTION #0201TB | DOB VIOLATION - ACTIVE |
| Nov 8, 2010 | ELEVATOR #9028/365010 | DOB VIOLATION - ACTIVE |
| Aug 26, 1999 | IMMEDIATE EMERGENCY #295/99 | DOB VIOLATION - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #03579 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| Jun 20, 2021 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Jun 29, 2020 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Mar 27, 2018 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Feb 16, 2017 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 10, 2009 | A | Apt 2L · SECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE STOPPER AT BATHTUB IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY | Dec 14, 2009 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 18, 2026 | ECB | Construction: (5:00AM) AT TIME OF INSPECTION OF THE SIDEWALK SHED AT EXP 1 AND 2 OF A 22 STORY MIXED USED BUILDING THE UNDERSIDE LIGHTS ARE LUMINATING AS REQUIRED TO CODE AT EXP 1 HOWEVER THERE IS NO UNDERSIDE LIGHTING AT EX | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)