10 floors · 12,340 sq ft · built 2005 · class H3 · owner of record: Essence Hotel Ii Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 52 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 52 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $390,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 104 days | No Cycle 10 report on record yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 10, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED GAS AND CARBON MONOXIDE SPILLAGE IN SPRINKLER ROOM. FROM HOT WATER HEATER UNITS. CON ED SHUT OFF BOTH HWT UNITS, AND A TAGGED BOTH. LOCATED AT BAS #39179968H | Mar 25, 2027 | $2,500 |
| Mar 10, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS. LOCATED AT BASEMENT LEVEL ON THE CEILING. PARTIAL HOLE COVERED WITH VENT GRILL COVERS., REPAIR AND/REPLACE #39179967X | May 21, 2026 DEFAULT | $6,250 |
| Feb 19, 2026 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN ELEVATOR MACHINE RM ON ROOM EXTENSION CORD BEING USED TO POWER A/C FROM OUTSIDE GFCI LO #39177995Y | Feb 26, 2027 | $1,600 |
| Jan 20, 2026 | Boilers CLASS - 2 @CELLAR MECH ROOM>GAS HOT WATER HEATERS HAVE CORRODED FLUE@HEATERS+IN DROP CEILING+DRAFT INDUCER@TOP OF CHIMNEY IS MISSING DRAFT PROVING SWITCH INTERLOCKED WITH EACH WATER HEATER, MAINTAIN BOILER; CORRECT VIOLA #39174457N | Jul 9, 2026 IN VIOLATION | $625 |
| Aug 13, 2024 | Unknown CLASS - 1 I OBSERVED ON ALL FLOORS THE FAILURE TO PROVIDE TAMPER-RESISTANT/PROOF RECEPTACLES AS PER LL 39/2015 RECEPTACLES IN THE COMMON HALLWAYS ACCESSIBLE TO CHILDREN SHALL BE MADE TAMPER PROOF. THIS IS AN IMMEDIATE SH #39121780Y | Jul 10, 2025 IN VIOLATION | $800 |
| Aug 13, 2024 | Unknown CLASS - 1 I OBSERVED IN THE ELEVATOR MOTOR ROOM, THE FIRST FLOOR, AND UNDER THE BASEMENT STAIRS THE UNPERMITTED USE OF FLEXIBLE CORDS AS PERMANENT WIRING, AS PER EC 400.8 FLEXIBLE WIRING SHALL NOT PASS THROUGH WALLS, CON #39121779R | Jul 10, 2025 IN VIOLATION | $800 |
| Aug 13, 2024 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT AREA ELECTRICAL ROOM AND THE ELECTRICAL GROUND SYSTEM IN THE WATER METER ROOM THE EQUIPMENT IN A STATE OF CORROSION DUE TO WATER LEAKS AND STANDING WATER CONDITIONS. AS PER EC 110.11 #39121781X | Jul 10, 2025 IN VIOLATION | $1,600 |
| Aug 8, 2024 | Construction CLASS - 1 OBSERVED RUSTED AND CORRODE GAS PIPING IN THE GAS METER ROOM LOCATED IN THE BASEMENT/CELLAR. AS PER 102.3 ON THE PLUMBING CODE MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINT #39121341M | Dec 11, 2025 IN VIOLATION | $312 |
| Aug 8, 2024 | Construction CLASS - 1 OBSERVED EXCESSIVE STORAGE IN THE MECHANICAL ROOMS THROUGHOUT BUILDING AND ALSO IN THE GAS METER ROOM LOCATED IN THE BASEMENT/CELLAR. AS PER E3 OF THE FUEL GAS CODE GAS METER ROOMS, WHEN PROVIDED, SHALL AT ALL #39121340K | Dec 11, 2025 IN VIOLATION | $312 |
| Aug 6, 2024 | Boilers CLASS - 1 FLUE SPILLAGE AT THE DIVETER OF BOTH RHEEM WATER HEATERS. FLUE PIPE IS CORRODED & THERE IS NO CHIMNEY CLEAN OUT FOR THE FLUE PIPE.CEASE USE BOTH WATER HEATERS. CORRECT ALL HAZARDOUS CONDITIONS IMMEDIATELY., MAI #39120983J | Oct 10, 2024 IN VIOLATION | $937 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 9, 2026, 3:50 PM ET. BBL 1007340007.