6 floors · 77 apartments · 63,103 sq ft · built 1920 · class D6 · owner of record: Gvs Properties Ii, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 63,103 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 314 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 435 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2180). Agency page | Dec 31, 2030 in 1531 days | Next due 2030 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-21 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 20, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER CHUTE DOOR, AT PUBLIC HALL, 3rd STORY, SECTION ''NORTH'' | Aug 3, 2026 |
| Jul 20, 2026 | A | Apt 3J · § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Oct 23, 2026 |
| Jul 20, 2026 | B | Apt 3J · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Aug 24, 2026 |
| Jul 20, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLIES AT HOPPER CHUTE DOOR AT PUBLIC HALL, 3rd STORY, SECTION ''NORTH'' | Aug 24, 2026 |
| Jul 1, 2026 | B | Apt 6O · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 6O · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , S | Aug 5, 2026 |
| Jul 1, 2026 | B | Apt 6O · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SEC | Aug 5, 2026 |
| May 6, 2026 | B | Apt 1F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT DOOR IN THE ENTRANCE LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jun 10, 2026 |
| Apr 20, 2026 | A | Apt 1F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BENT METAL DOOR IN THE ENTRANCE LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Jul 24, 2026 |
| Apr 20, 2026 | B | Apt 1F · § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | May 25, 2026 |
| Nov 6, 2025 | B | Apt 6O · § 27-2005 HMC: REFIT THE DOOR AT ENTRANCE IN THE BATHROOM LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST | Dec 11, 2025 |
| Nov 6, 2025 | B | Apt 6O · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST | Dec 11, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Jul 20, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER CHUTE DOOR, AT PUBLIC HALL, 3rd STORY, SECTION ''NORTH'' | Open |
| Jul 20, 2026 | HPD A | § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Open |
| Jul 20, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE AT WATER CLOSET IN THE BATHROOM LOCATED AT APT 3J, 3rd STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''NORTH'' | Open |
| Jul 20, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH AND ITS ASSEMBLIES AT HOPPER CHUTE DOOR AT PUBLIC HALL, 3rd STORY, SECTION ''NORTH'' | Open |
| Jul 1, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION AT NORTH | Open |
| Jul 1, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , S | Open |
| Jul 1, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6O, 6th STORY, 3rd APARTMENT FROM NORTH AT EAST , SEC | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 9:52 AM ET. BBL 1021800507.