2 floors · 32,764 sq ft · built 1920 · class Y2 · owner of record: Nyc Police Department
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 58 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-23 (Pre-filing). Agency page | Dec 31, 2026 in 58 days | 1 of 1 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 32,764 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 6, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER AT TIME OF INSPECTION.NOTED:AT EXP.#3 VERTICAL CRACK APPROX. 4' X 3/4" IN MASONRY WALL. REMEDY:COMPLY W/CODE #35636091X | Mar 3, 2022 POP/IN-VIO | $0 |
| Oct 18, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION REAR OF BLDG AT EXP #3 INREPAING WALL VERTICA CRACK IN TWO PLACE ONE 4 FT LONG OTHER 2 FT LONG BRICK MISSING IN TOP OF WALL.REPAIR OR #35592098R | Jan 20, 2022 POP/IN-VIO | $0 |
| Aug 19, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION AT REAR OF BLDG EXP #3 RETAINING WALLS HAS VERTICAL CRACK APROX 4" WIDE AND 42" LONG.REMEDY:COMPLY WITH CODE. #35582160J | Dec 16, 2021 POP/IN-VIO | $0 |
| Jul 2, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE AT REAR OFBLDG EXPOSURE#3 THE RETAINING WALL HAS VERTICAL CRACKS APPROX 4"WIDE X42"LONG ALSO NON PUBLIC WALKWAY HAS CRACKS AND SPALLING CONCRETE. REME #35558028M | Oct 7, 2021 POP/IN-VIO | $0 |
| May 10, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER AT THE TIME OF MY INSPECTION NOTED AT REAR OF BUILDING BRICK RETAINING WALL HAS VERTICAL CRACK APPROX 4'X42'' ALSO NON PUBLIC CONCRETE WALKWAY IS SEVERLY CR #35560859X | Aug 26, 2021 POP/IN-VIO | $0 |
| Mar 24, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE AT REAR YARD BRICK RETAINING WALL IN DISREPAIR WITH VERTICAL AND HORIZONTAL CRACKS ALSO MISSING MORTAR. REMEDY: REPAIR AND OR REPLACE #35555966P | Jun 24, 2021 POP/IN-VIO | $0 |
| Feb 3, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED: BUILDING RETAINING BRICK WALL AT REAR IN DISREPAIR WITH VERTICAL AND HORIZONTAL CRACKS. ALSO, DETERIORATED WITH DEGRADED MORTAR THROUGHOUT., REPAI #39035766R | Feb 22, 2021 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #01845 | DOB VIOLATION - ACTIVE |
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #01316 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 9:33 PM ET. BBL 1020660009.