Brooklyn · Block 453 · Lot 26 · 11215

444 Carroll Street

class G7 · owner of record: Gw Carroll Llc

6open violations
$32,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
—no dated deadlines found

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

We couldn't find building attributes for this lot, so no deadlines are listed.

Open violations

ECB / OATH (8) · $32,500 owed
IssuedViolationHearingBalance
Sep 15, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED AT EXPOSURE #4 NO OVERHEAD PROTECTION FOR ADJACENT PROPERTY'S BALCONY. FACADE INCOMPLETE. FAILURE TO PROVIDE OVERHEAD PROTECTION CREATES HAZARD FOR PU
#39559162N
Nov 25, 2026
PENDING
$10,000
Sep 15, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED BAKER SCAFFOLD ON SITE AT VARIOUS LOCATION WITHOUT OUTRIGGERS TO PREVENT IT FROM FALLING. FAILURE TO PROVIDE AND MAINTAIN THE BAKER'S SCAFFOLD IN ACCO
#39559161L
Nov 25, 2026
PENDING
$2,500
Sep 15, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED AT EXPOSURE #1, ADJACENT TO SIDEWALK SHED MATERIALS STORED ON STREET AND DELIVERY TRUCK. THERE WAS NO 4 FEET SOLID BARRIER FROM GROUND LEVEL WITH 18 G
#39559160J
Nov 25, 2026
PENDING
$5,000
Sep 11, 2026Unknown CLASS - 2
BC 3308.7-GUARDRAIL SYSTEM-OBSERVED INADEQUATE GUARDRAIL SYSTEM ON WINDOWS OPENING THROUGH OUT WHOLE BUILDING-ALL GUARDRAIL SYSTEM MISSING/NOT INSTALLED TOE BOARD AS REQUIRED(DEBRIS VISIBLE BEHIND ON BALCONIES)
#39559096Y
Nov 18, 2026
PENDING
$2,500
Sep 11, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION I OBSERVED VERY BIG AMOUNT/PILES OF GARBAGE/DEBRIS ACCUMULATED IN COURTYARD WITH WORKERS WORKING AROUND IT/WALKING THROUGH IT-MAKING IN HAZARDOUS FALL/FIRE CONDITIONS
#39559099J
Nov 18, 2026
PENDING
$2,500
Sep 11, 2026Unknown CLASS - 2
OSUPPORTED SCAFFOLD INSTALLED AT EXP#4 APPROX. 2 FEET FROM ADJOINING PROPERTY WINDOWS(436 CARROLL STR) -SUPPORTED SCAFFOLD NET ON SIDE WAS NOT TIED ADEQUATELY/LOOSE , PLATFORM(PLANKS) CLOSE TO WINDOWS,NO TOE BO
#39559097X
Nov 18, 2026
PENDING
$2,500
Mar 4, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A PROPOSED 6-STORY NEW BUILDING AT SOE PHASE. I OBSERVED EXCAVATION OPERATION AND PREPARATION FOR PILE INSTALLATION, UPON REVIEW OF SITE SAFETY PLANS, IT SHOWS PILE MACHINE AND E
#39551193J
Feb 9, 2027
$2,500
Mar 4, 2026Unknown CLASS - 1
3307.2.1.-AT THE TIME OF INSPECTION OF A PROPOSED 6-STORY NEW BUILDING AT SOE PHASE. I OBSERVED PEDESTRIAN WALKWAY YODOK JERSEY BARRIERS ON STREET WAS 39 INCHES AT EXPOSURE #1, UPON REVIEW OF DOT PERMIT, PEDEST
#39551194L
Feb 9, 2027
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 15, 2026ECBUnknown: AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED AT EXPOSURE #4 NO OVERHEAD PROTECTION FOR ADJACENT PROPERTY'S BALCONY. FACADE INCOMPLETE. FAILURE TO PROVIDE OVERHEAD PROTECTION CREATES HAZARD FOR PUOpen
Sep 15, 2026ECBConstruction: AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED BAKER SCAFFOLD ON SITE AT VARIOUS LOCATION WITHOUT OUTRIGGERS TO PREVENT IT FROM FALLING. FAILURE TO PROVIDE AND MAINTAIN THE BAKER'S SCAFFOLD IN ACCOOpen
Sep 15, 2026ECBUnknown: AT THE TIME OF INSPECTION SIX-STORY NEW BUILDING I OBSERVED AT EXPOSURE #1, ADJACENT TO SIDEWALK SHED MATERIALS STORED ON STREET AND DELIVERY TRUCK. THERE WAS NO 4 FEET SOLID BARRIER FROM GROUND LEVEL WITH 18 GOpen
Sep 11, 2026ECBConstruction: OBSERVED NEEDLE BEAMS WITH 3.5' SUPPORTED SCAFFOLD INSTALLED AT 4TH FL-EXP#2 CONTRARY TO PLANS -BEAMS NOT ATTACHED TO SLAB WITH ANGLES/BOLTS THROUGH SLAB,NO STEEL PLATES ANCHORED TO SLAB -STOP ALL USE OF NEEDLClosed
Sep 11, 2026ECBConstruction: SUPPORTED SCAFFOLD INSTALLED IN COURTYARD CONTRARY TO PLANS-FIRST ROW USING 5' FRAME THEN 2' FRAME ON TOP -NOT ON PLANS,USING CLAMPS FOR CROSS BRACING-NOT ON PLANS,CONFIGURATION OF FRAMES ON BALCONIES NOT AS ONClosed
Sep 11, 2026ECBUnknown: BC 3308.7-GUARDRAIL SYSTEM-OBSERVED INADEQUATE GUARDRAIL SYSTEM ON WINDOWS OPENING THROUGH OUT WHOLE BUILDING-ALL GUARDRAIL SYSTEM MISSING/NOT INSTALLED TOE BOARD AS REQUIRED(DEBRIS VISIBLE BEHIND ON BALCONIES)Open
Sep 11, 2026ECBConstruction: AT THE TIME OF MY INSPECTION I OBSERVED VERY BIG AMOUNT/PILES OF GARBAGE/DEBRIS ACCUMULATED IN COURTYARD WITH WORKERS WORKING AROUND IT/WALKING THROUGH IT-MAKING IN HAZARDOUS FALL/FIRE CONDITIONSOpen
Sep 11, 2026ECBUnknown: OSUPPORTED SCAFFOLD INSTALLED AT EXP#4 APPROX. 2 FEET FROM ADJOINING PROPERTY WINDOWS(436 CARROLL STR) -SUPPORTED SCAFFOLD NET ON SIDE WAS NOT TIED ADEQUATELY/LOOSE , PLATFORM(PLANKS) CLOSE TO WINDOWS,NO TOE BOOpen