Brooklyn · Block 709 · Lot 21 · 11232

444 39 Street

1 floors · 18,000 sq ft · built 1969 · class K1 · owner of record: 444 39th St Corp

9open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1162dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-05 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Aug 23, 2010Boilers CLASS - 1
B154/51/3B/3A/50A/50B/50A-FLUE PIPE CORRODE-HOLES,FUMES HEAVY C.O. 275PPM & CLIMING BOILER SEALED/50B-DO NOT OPERATE BOILER WITH ALL HAZARDOUS CONDITIONS ARE IMMEDIATELY CORRECTED & DOB IS NOTIFIED TO REINSPECT
#32069462Z
Oct 18, 2010
IN VIOLATION
$0
Aug 21, 2010Boilers CLASS - 1
B154/34B/15/32A/36/3A/50A/50B/50C/50D/50A-FLUE PIPE CORRODED HOLES MUST BE REPLACE IMMEDIATELY/50B-NO EMERGENCE FUEL CUTOFF SWITCH OUT OF BLROOM FIRE DOOR/50C-SEALED AROUND FLUE PIPE TO BL RM CEILING OPENING
#32069458X
Oct 18, 2010
IN VIOLATION
$0
Oct 16, 2007Boilers Non-Hazardous
B4A,34B,50A,B,C,D,24B,36.50A-HOLES IN CEILING OVER BOILER & STORAGE TANK.50B-BOILER JACKET PROPOSED UP BY 2 X 4.50C-NO CHECK VALVE BEFORE BACKFLOW & BOILER.50D-STORAGE TANK RELIEF VALVE PIPED DOWN W/PVC FITTING
#32052649H
Feb 4, 2008
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Dec 2, 2010FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00893
DOB VIOLATION - ACTIVE
Dec 2, 2010FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00894
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Dec 2, 2010AEUHAZ FTC-AEU-HAZ
Active
Dec 2, 2010AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 7:30 AM ET. BBL 3007090021.