| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2025-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-12-10 (Accepted). Agency page | Dec 31, 2026 in 65 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 430 days | Next cycle year 2027 |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| May 30, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING AT CELLAR | Jul 4, 2025 |
| May 30, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BOILER ROOM DOOR (HINGES) AT CELLAR | Jun 13, 2025 |
| Mar 13, 2024 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES ALL BALCONIES AT FIREESCAPE AT EAST | Jun 16, 2024 |
| Nov 25, 2020 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE METAL STRIKER PLATE AT ENTRANCE DOOR TO BUILDING | Dec 1, 2020 |
| Dec 14, 2018 | A | § 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT THE FIRE ESCAPE , SECTION AT EAST | Mar 19, 2019 |
| Dec 14, 2018 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR LOCK TO BUILDING | Dec 22, 2018 |
| Dec 13, 2018 | B | Apt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 17, 2019 |
| Jun 8, 2018 | B | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AT BUILDING FRONT ENTRANCE DOOR , 1st STORY | Jul 13, 2018 |
| Jun 5, 2008 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOCKING ASSEMBLY TO 1 STY PUBLIC HALL. | Jul 10, 2008 |
| Jun 5, 2008 | A | D26-10.01 ADM CODE REFIT DOOR BOILER ROOM AT CELLAR. | Sep 8, 2008 |
| Jun 5, 2008 | B | § 27-2005 ADM CODE PROVIDE BRACKETS AIR CONDITIONER 2 STY FRONT WEST. | Jul 10, 2008 |
| Jun 5, 2008 | C | Apt 1A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY OPERATED LOCK ENTRANCE DOOR 1 STY APT 1A. , SECTION '' '' | Jun 11, 2008 |
| Jun 5, 2008 | B | Apt 1A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 1 STY APT 1A. , SECTION '' '' | Jul 10, 2008 |
| Jun 5, 2008 | C | Apt 1A · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DOUBLE CYLINDER KEY LOCK ENTRANCE DOOR TO 1 STY APT 1A. LOCATED AT APT 1A | Jun 11, 2008 |
| Jun 5, 2008 | A | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE KNOB ASSEMBLY 1 STY PUBLIC HALL VESTIBULE DOOR. | Sep 8, 2008 |
| Jun 5, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD CEILING CELLAR FRONT & REAR. | Jul 10, 2008 |
| Jun 5, 2008 | B | D26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF PAINT CANS & BUILDING MATERIALS 3 STY PUBLIC HALL BULKHEAD INTERMEDIATE LANDING. | Jul 10, 2008 |
| Jun 5, 2008 | B | Apt 1A · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR VALVE SOUTH ROOM 1 STY WEST APT 1A. LOCATED AT APT 1A | Jul 10, 2008 |
| Jul 28, 2006 | A | Apt 1A · § 27-2026 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL BATHROOM 1 STY SOUTHWEST APT 1A. LOCATED AT APT 1A | Nov 24, 2006 |
| Jul 28, 2006 | A | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE ENTRANCE DOOR VESTIBULE TO 1 STY PUBLIC HALL. | Nov 24, 2006 |
| Jul 28, 2006 | A | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE DOOR VESTIBULE TO 1 STY PUBLIC HALL. | Nov 24, 2006 |
| Jul 28, 2006 | A | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE VESTIBULE DOOR 1 STY PUBLIC HALL. | Nov 24, 2006 |
| Jan 27, 1998 | B | Apt 1A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE 1 STY SOUTHWEST APT 1A. , SECTION '' '' | Mar 16, 1998 |
| Jul 16, 1991 | B | Apt 1A · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET BATHROOM 1 STY SOUTHWEST APT 1A. LOCATED AT APT 1A | Sep 2, 1991 |
| Jun 25, 1991 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING BATHROOM 1 STY SOUTHEAST APT 1A. LOCATED AT APT 1A | Aug 12, 1991 |
| Jun 25, 1991 | C | Apt 1A · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET BATHROOM 1 STY SOUTHEAST APT 1A ER1. LOCATED AT APT 1A | Jul 15, 1991 |
| Apr 30, 1991 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOCKING ASSEMBLY ENTRANCE DOOR 1 STY PUBLIC HALL. | Jun 17, 1991 |
| Apr 30, 1991 | B | Apt 1A · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE 1 STY WEST APT 1A. LOCATED AT APT 1A | Jun 17, 1991 |
| Mar 5, 1991 | B | Apt 1A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE 1 STY APT 1A. , SECTION '' '' | Apr 22, 1991 |