4 floors · 6 apartments · 7,462 sq ft · built 1935 · class S9 · owner of record: Winfinitec Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 67 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-02 (Accepted). Agency page | Dec 31, 2026 in 67 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 83 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 8, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #39044112M ISSUED ON 07/08/21 AND TO FILE CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.FAILURE TO MAINTAIN.REMEDY:CO #35562253K | Jan 19, 2022 IN VIOLATION | $1,250 |
| Jul 8, 2021 | Construction CLASS - 1 AT FACADE OF BUILDING FRONTING 4TH AVE., ABOVE 1ST FLOOR COMMERCIAL SPACE, SECTION OF CORNICE THAT WAS LOOSE HAS BEEN REMOVED BY FDNY, ALSO NOTED SECTION OF FASCIA AT CORNER EXP. 1 + 4 ALSO MISSING., MAINTAIN E #39044112M | Nov 10, 2021 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Sep 29, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00224 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Sep 29, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 21, 2026 | B | Apt 3L · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRING AT NORTH WALL IN THE KITCHEN LOCATED AT APT 3L, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | May 26, 2026 |
| Mar 30, 2026 | C | Apt 1F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERABLE RADIATOR AT THE NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 5, 2026 |
| Mar 30, 2026 | C | Apt 1F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE SINK IN THE KITCHEN LOCATED AT APT 1F, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Apr 5, 2026 |
| Mar 24, 2026 | C | Apt 3R · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 24, 2026 |
| Mar 24, 2026 | C | Apt 3L · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 24, 2026 |
| Mar 24, 2026 | C | Apt 3R · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 24, 2026 |
| Mar 24, 2026 | C | Apt 3L · § 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 24, 2026 |
| Feb 25, 2025 | B | Apt 3F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT CEILING, THE NORTH AND EAST WALL IN THE BATHROOM LOCATED AT APT 3F, 4th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17366851 ISSUED 23-OCT-24 HAS BEEN UPGRADED TO CLASS B PER ADM | Apr 1, 2025 |
| May 16, 2024 | C | Apt 2F · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPRATURE OF 130 DEGREES AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 22, 2024 |
| Nov 29, 2023 | C | Apt 2F · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOTWATER EXCEEDED MAXIMUM ALLOW TEMPERATURE OF 130.F DEGREES AT HOTWATER FIXTURES, IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 5, 2023 |