Staten Island · Block 2402 · Lot 20 · 10314

442 Nome Avenue

1 floors · 3,120 sq ft · built 1989 · class K1 · owner of record: 2203 3rd Ave Llc

8open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1140dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Apr 14, 2015Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS FOR ALT2 JOB#520141490 FOR WHICH PERMIT EXPIRED 6/6/14.NON CONFORMING WORK OBSERVED @ 1ST FL "BARLOS" ITALIAN RESTAURANT.NOTED TH
#35111037N
Jun 3, 2015
IN VIOLATION
$0
DOB (6)
IssuedViolationStatus
Jul 15, 2023STRUCTURALLY COMPROMISED BUILDING
FAILURE TO SUBMIT AN ACCEPTABLE INSPECTN RPT FOR STRUCTURALLY COMPROMISED BLDG.
#00052
DOB VIOLATION - ACTIVE
Jun 13, 2023CONSTRUCTION
EMERGENCY WORK.BLDG SFFRD A 2-ALARM FIRE ON 6/9/23 &SUSTAIND STRCTRL DMGE.APPRX 18FT X 32FT D AREA OF SAGGNG FIRE DMGED ROOF JOISTS@CENTER BAY IN FRNT 2/3 OF BLDG.MSNRY ROOF FIRE DMGD@FRONT.IMMED INSTALL TGHTBRD FENCE TO ENCLSE PRKNG AREA&WALKWAY ON ENTIRE FRNTAGE@FRNT&4 PRKNG SPACES ADJCNT TO UNSTB
#FEU50201BS
DOB VIOLATION - ACTIVE
Jun 13, 2023CONSTRUCTION
EMERGENCY WORK.BLDG SFFRD A 2-ALARM FIRE ON 6/9/23&SUSTAINED STRCTRL DMGE.APPRX 18FTW X 32FTD AREA OF SAGGNG FIRE DMGD ROOF JOISTS@CENTER BAY IN FRNT 2/3 OF BLDG.W/OPEN HOLES IN ROOF&HVAC UNIT LEANING.1.IMMED INSTALL TEMP SHORNG TO STBILIZE FIRE DMGD ROOF,2.ALL WRK TO BE DRCTD& SPRVSD DRCTLY BY ONSI
#FEU50202BS
DOB VIOLATION - ACTIVE
Jun 13, 2023CONSTRUCTION
FTM.BLDG SFFRD A 2-ALARM FIRE ON 6/9/23&SUSTAIND STRUCTURAL DMGE.APPRX 18FT X 32FT D AREA OF SAGGNG FIRE DMGD ROOF JOISTS@CENTERBAY IN FRNT 2/3 OF BLDG.MULT OPEN HOLES IN ROOF&HVAC UNIT LEANING INTO.1.NYS PE STRCTRL ENGNEER TO IMMED EVAL ENT BLDG&DSGN RPAIRS,2.FILE FOR RPAIRS BY 8/14/23,3.OBTN PRMTS
#FEU50203BS
DOB VIOLATION - ACTIVE
Jun 9, 2023CONSTRUCTION
AT TIME OF INSPECTION OBSERVED EXCESSIVE FIRE AND WATER DAMAGE, ROOF OPEN TO THE ELEMENTS, ROOF SAGGING WALLS AND CEILING DAMAGED DUE TO FIRE.
#23-01822
DOB VIOLATION - ACTIVE
Jun 9, 2023CONSTRUCTION
DUE TO FIRE
#ER01MP
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Jul 15, 2023Structurally Compromised Buildings FTF-SC-INITL
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 1:26 PM ET. BBL 5024020020.