3 floors · 2 apartments · 2,928 sq ft · built 1899 · class B3 · owner of record: 442 Lafayette Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 303 days | Required only if the owner doesn't live there |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 4, 2009 | B | Apt 2FL · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2FL, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2FL · SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CEILING AT STEAM RISER IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2FL, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2FL · SECTION 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2FL, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTERS AT PUBLIC HALL STAIRS, 1st STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | SECTION 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL AT PUBLIC HALL STAIRS, 1st STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTERS AT PUBLIC HALL, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | B | Apt 2FL · SECTION 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET TANK IN THE BATHROOM LOCATED AT APT 2FL, 2nd STORY | Sep 8, 2009 |
| Aug 4, 2009 | C | SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STORY APT. #2, KITCHEN AND BATHROOM. | Aug 10, 2009 |
| Aug 4, 2009 | C | SECTION 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF UNCAPPED STEAM PIPE RADIATOR, 2ND STORY APT. #2, BATHROOM. ER1 | Aug 10, 2009 |
| Aug 4, 2009 | B | SECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING SHOWER CURTAIN ROD BATHTUB, 2ND STORY APT. #2, BATHROOM. | Sep 8, 2009 |
| Aug 4, 2009 | B | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES, 2ND STORY APT. #2. | Sep 8, 2009 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 2, 2026, 8:55 PM ET. BBL 3019490036.