6 floors · 10 apartments · 37,689 sq ft · built 2019 · class DB · owner of record: Con Ml Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 37,689 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 185 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 185 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 429 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 20, 2025 | Unknown CLASS - 1 BC3301.2 SAFETY MEASURES.OBSERVED 2 WORKERS PERFORMING EXTERIOR WORK AND STANDING ON 2ND FL PARAPET WALL WITH NO SAFETY MEASURES(FALL ARREST SYSTEM). 2 OPENINGS ON SIDEWALK SHED DECK APPROX. 3X10FT WITH NO SAFE #39536136H | May 12, 2026 IN VIOLATION | $5,000 |
| Jan 20, 2025 | Construction CLASS - 2 OBSERVED STORAGE OF MATERIALS ON ROADWAY AT EXP#1&4 ADJACENT TO SIDEWALK SHED. WITH NO PEDESTRIAN PROTECTION PROVIDED SUCH AS FENCE/BARRIERS/WIRE SCREEN AT LEAST 8 FT HIGH FROM GROUND ATTACHED TO SIDEWALK SHED #39536134Y | May 12, 2026 IN VIOLATION | $2,400 |
| Jan 20, 2025 | Unknown CLASS - 1 OBSERVED TWO WORKERS PERFORMING EXTERIOR WORK AND STANDING ON TOP OF 2ND FLOOR PARAPET WALL WITH NO SAFETY MEASURES. UPON REQUEST FROM THEM TO PROVIDE THE REQUIRED TRAINING SUCH AS SST AND OSHA CARDS, THEY BOTH #39536135X | May 12, 2026 IN VIOLATION | $2,500 |
| Jan 20, 2025 | Construction CLASS - 1 OBSERVED STORAGE ZONE AT EXP#1&4 WHERE MATERIALS STORED ON ROADWAY, UPON REVIEW THE APPROVED SSP DID NOT OBSERVE ANY INDICATION ON SSP FOR ANY STORAGE ZONE ON ROADWAY AT EXP#1&4STOP ALL USE AND WORK ON STORAGE #39536133M | May 12, 2026 IN VIOLATION | $2,500 |
| Mar 23, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION FOR CLASS1 VIO#39508715Y, SITE IS CLOSED, UPON REVIEWING DEPARTMENT RECORDS NO CERTIFICATE OF CORRECTION ON FILE ASSOCIATED WITH THE ABOVE MENTIONED VIOLATION. RESPONDENT FAILED TO COMPLY #39514516M | Jun 7, 2023 DEFAULT | $3,125 |
| Jan 17, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION I OBSERVED THAT THE RESPONDENT FAILED THE CORRECT THE CONDITIONS REGARDING THE HAZARDOUS VIOLATION #39508715Y SERVED ON 11-03-2022. AT EXP# 1 & 4 STEEL INSTALLATION PASS THE HEIGHT OF THE #39511760K | Apr 5, 2023 DEFAULT | $12,500 |
| Nov 3, 2022 | Construction CLASS - 1 NOTED: AT TIME OF INSPECTION OF AN NONE ACTIVE JOBSITE. OBSERVED AT EXP # 1 AND 4 STEEL INSTALLATION PASS THE HEIGHT OF THE FENCE APPROX 12FT AND UPON REVIEWING BIS/DOB NOW OBSERVED PERMIT WAS ISSUED TO INSTALL #39508715Y | Mar 8, 2023 DEFAULT | $12,500 |
| Feb 15, 2022 | Construction CLASS - 2 EXPIRED TERMS OF PERMIT FOR TEMPORARY EQUIPMENT(FENCE PERMIT EXPIRED).NOTE-AT TIME OF INSPECTION OF A PROPOSED 7 STORY NEW BUILDING I OBSERVED THAT THE PERMIT FOR THE CONSTRUCTION FENCE#320891843-01-EQ-FN HAD E #35642135J | Jul 6, 2022 DEFAULT | $3,125 |
| Jun 12, 2019 | Construction CLASS - 2 FAILURE TO PROVIDE FIELD STORAGE CURING BOX @CONST SITE. AS NOTED @TIME IF MY INSPECTION ACTIVE SITE SOE PHASE I OBSERVED 6 4"*8" STRNGTH TEST AGLINDERS CASTED ON 6/11/19 BY INTERTEK MT GROUP AND IT WAS LEFT #35254524Z | Jan 30, 2020 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #28430 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 6, 2026 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT AT PUBLIC HALL, 1st STORY | Jan 9, 2027 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 6, 2026 | HPD A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT AT PUBLIC HALL, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 28, 2026, 10:49 AM ET. BBL 3056100001.