Manhattan · Block 29 · Lot 73 · 10004

44 Beaver Street

12 floors · 97,596 sq ft · built 1920 · class O3 · owner of record: Nyc Department Of Sanitation

46open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
118dto Facade inspection report (Cycle 10A)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 118 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 97,596 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 29). Agency page

Dec 31, 2029
in 1162 days
Next due 2029

Open violations

ECB / OATH (5)
IssuedViolationHearingBalance
Nov 6, 2023Construction CLASS - 1
FAILURE TO MAINTAIN EXTEIROR BUILDING FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE #4 (WEST) CRACKED STONE PARAPET LEVEL. REMEDY: MAINTAIN EXTERIOR FACADE AND APPURTENANCES. PROVIDE SAFETY MEASURES AND
#35675123N
Nov 7, 2023
POP/IN-VIO
$0
Feb 7, 2022Construction CLASS - 1
FAILURE TO PROVIDE SAFETY MEASURES SUCH AS SIDEWALK SHEDS;NETTING,FENCE,ETC WHERE REQUIRED TO PROTECT AND SECURE PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE AS PER 1RCNY 103-04. FACADE TECHNICAL REPORT FILED UN
#35640145Y
May 19, 2022
POP/IN-VIO
$0
Dec 13, 2021Construction CLASS - 1
FAILURE TO TAKE&PROVIDE SAFETY MEASURES.SWS/NETTING (ILLEGIBLE)&PROTECT PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE.(FISP3) UNSAFE NOTIFICATION RECD11/30/21 FILED FACADE UNSAFE.NO SAFETY MEASURES IN PLACE&@S EL
#35635237P
Mar 17, 2022
POP/IN-VIO
$0
Nov 15, 2019Construction CLASS - 2
SEC. 27-929.1 A.C.27-929.1,FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRIKLERS & FILE A FINAL SPRINKLER REPORT PREPARED BY A REGISTERED DESIGN PROFESSIONAL BY 7/1/19,IN AN OFFICE BLDG
#37016896Z
Jan 23, 2020
POP/IN-VIO
$0
Jun 14, 1994Construction Non-Hazardous
ALTERED BUILDING: OCUPIED UNDER ALTERATION #1474/88 WITHOUT A VALID CERTIFICATE OF OCUPANCY. REMEDY: OBTAIN A CERTIFICATE OF OCCUPANCY.
#34112931X
Aug 11, 1994
WRITTEN OFF
$0
DOB (8)
IssuedViolationStatus
Feb 17, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#909959
DOB VIOLATION - ACTIVE
Feb 17, 2022FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS
#00246
DOB VIOLATION - ACTIVE
Jun 20, 2021FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020)
#00003
DOB VIOLATION - ACTIVE
Jun 29, 2020FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2019
#10004
DOB VIOLATION - ACTIVE
Sep 3, 2019SPRINKLER
FAILED TO FILE FINAL SPRINKLER REPORT BY JULY 1, 2019
#NRF00029
DOB VIOLATION - ACTIVE
Nov 1, 2006PHOTOLUMINESCENT

#NRF00327
DOB VIOLATION - ACTIVE
Jun 13, 1989PUBLIC ASSEMBLY

#0801AP
DOB VIOLATION - ACTIVE
Jan 30, 1989LOCAL LAW 5/73

#C30054
DOB VIOLATION - ACTIVE
DOB NOW Safety (33)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Feb 17, 2022Facades FISPFCS
CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS
Active
Feb 17, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Jun 20, 2021Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Jun 29, 2020Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Sep 3, 2019Sprinklers FTF-SP-FINAL
Active
Nov 1, 2006Photoluminescent FTF-EL-PHOTOL
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 4:41 AM ET. BBL 1000290073.