26 floors · 77 apartments · 460,973 sq ft · built 1931 · class D4 · owner of record: River House Realty Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 460,973 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1364). Agency page | Dec 31, 2034 in 2968 days | Next due 2034 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $543,870 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: UNSAFE (2025-12-19) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 15, 2026 | Construction CLASS - 2 DURING INSPECTION OF THE 26-STORY BUILDING INTERIOR RENOVATION OF THE EXISTING RESIDENTIAL UNIT #10G, OBSERVED ACTIVE SITE UPON REQUEST OF SITE SAFETY PLAN, DAILY LOGS, PRE-SHIFT MEETING, WORKER SAFETY ORIENTAT #39559165Z | Nov 19, 2026 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 1 26 STORY ALT2 FACADE WORK ACTIVE SITE. OBSERVED A FRAME LADDER ATTACHED TO 2 20 FT DROPDOWN LADDERS ON 16,15,14 FLOORS BELOW ON SETBACKS FOR ACCESS TO SUSPENDED SCAFFOLD. WITHIN 6 FEET OF LEADING EDGE WITHOUT, #39553739L | May 13, 2027 PENDING | $10,000 |
| May 1, 2026 | Construction CLASS - 2 26 STORY ALT2 FACADE WORK ACTIVE SITE.SUSPENDED SCAFFOLDS IN USE/PLACE PERMIT#M01266799. OBSERVED PARAPET CLAMPS ON PARAPET WALL ON 15 FLOOR SETBACK EXP#4 ATTACHED TO OUTRIGGER BEAMS ON 14 FL EXP#3. UPON REQUES #39553741K | May 13, 2027 | $1,250 |
| Jun 20, 2017 | Unknown CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004126 HAS BEEN INSPECTED, TESTED & DISINFECTED & THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED & IMPLEMENTED BY 11/1/16. REM: FILE ANNUAL CERTIFICATION. #37003357R | Apr 19, 2018 IN VIOLATION | $0 |
| Jun 20, 2017 | Unknown CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004128 HAS BEEN INSPECTED, TESTED & DISINFECTED & THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED & IMPLEMENTED BY 11/1/2016. REM: FILE ANNUAL CERTIFICATIO #37003359K | Apr 19, 2018 IN VIOLATION | $0 |
| Jun 20, 2017 | Unknown CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004124 HAS BEEN INSPECTED, TESTED & DISINFECTED & THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED & IMPLEMENTED BY 11/1/2016. REM: FILE ANNUAL CERTIFICATIO #37003358Z | Apr 19, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 18, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE. NOTED AT TIME OF INSPECTION EXPOSURE 3 NORTH ELEVATION CRACKED MASONRY AT PARAPET LEVEL. REMEDY: FIX AND/OR REPLACE #SR10602BB | DOB VIOLATION - ACTIVE |
| Feb 25, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AT TIME OF INS PECTION,OBSERVED AT ROOF LEVEL,CRACKED COPPING STONE AT EXP3 SPALLING SPALLING CRACKED STONE MISSING PARAPET AT EXP2 NEAR ENTRANCE.REMEDY:RE PAIR AND/OR REPLACE #SR10601DO | DOB VIOLATION - ACTIVE |
| Sep 20, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AT TIME OF INS PECTION,IT WAS OBSERVED AT EXP1 SOUTH ELEV 1/3 CORNER,A CRACK SPANNING ALONG LINTEL TOP WATER TABLE CORNICE OVER A PREVIOUS REPAIR AND AT ROO F,A BROKEN/CRACKED COPING STONE ALONG EXP3 WAS OBSERVED.REMEDY:REPAIR AND/OR REPLACE #SR10601MA | DOB VIOLATION - ACTIVE |
| Feb 18, 2022 | HAZARDOUS CONDITION (FACADE) CYCLE 9A UNSAFE REPORT FILED #909806 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #04547 | DOB VIOLATION - ACTIVE |
| Apr 19, 2019 | ELEVATOR #9028/650019 | DOB VIOLATION - ACTIVE |
| Dec 5, 2017 | FACADE SAFETY PROGRAM #HAZ87051 | DOB VIOLATION - ACTIVE |
| Nov 21, 2002 | ELEVATOR 1P16939 #9444/164543 | DOB VIOLATION - ACTIVE |
| Jan 23, 1995 | CONSTRUCTION #05C4 | VIOLATION UNSERVED ECB-ACTIVE |
| Nov 22, 1988 | ELEVATOR (31) CAR STOPS HIGH OR LOBBY FLOOR (33 & 34) REPLACE DOUR GIBS WHERE NEEDED (51) ELIMINATE VIBRATION FROM MOTOR AND MACHINE (28) CLEAN #14556-1 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 15, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-NJ Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-NJ Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Feb 18, 2022 | Facades FISPHAZ CYCLE 9A UNSAFE REPORT FILED | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Dec 5, 2017 | Facades FISP CYCLE 8A UNSAFE REPORT FILED | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 15, 2026 | ECB | Construction: DURING INSPECTION OF THE 26-STORY BUILDING INTERIOR RENOVATION OF THE EXISTING RESIDENTIAL UNIT #10G, OBSERVED ACTIVE SITE UPON REQUEST OF SITE SAFETY PLAN, DAILY LOGS, PRE-SHIFT MEETING, WORKER SAFETY ORIENTAT | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)