7 floors · 60 apartments · 41,617 sq ft · built 1963 · class D3 · owner of record: 10524 Emmut Properties Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 50 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 41,617 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 171 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 171 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 833 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 10, 2026 | Construction CLASS - 1 B. C. 907.2.8. FAILURE TO PROVIDE A CLASS "1" FIRE ALARM SYSTEM FOR TRANSIENT USE AT UNIT 74 ON THE 7TH FLOOR. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. #35729345J | Dec 3, 2026 PENDING | $2,500 |
| Aug 10, 2026 | Quality of Life CLASS - 2 PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DEPARTMENT OF BUILDINGS RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING. ILLEGAL OCCUPANCY NOTE #35729344H | Oct 15, 2026 IN VIOLATION | $1,250 |
| Apr 4, 2019 | Construction CLASS - 1 AT TIME OF INSPECTION AT AN ACTIVE 7 STORY NEW BUILDING CONSTRUCTION SITE, I OBSERVED REAR BUILDING ON/AT 442 WEST 54 STREET DID NOT ERECT ADJOING PROPERYT CHIMNEY AT MINIMUM REQUIREMENT AS PER SECTION 2113.1. #35402624H | Aug 15, 2019 IN VIOLATION | $1,250 |
| Nov 29, 2018 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER.NOTED:AT TIME OF POSTING OF VIOLATION OBSERVED ON 11/27/18 I OBSERVED THE STOP WORK ORDER STICKER HAD BEEN REMOVED FROM FRONT ENTRY DOOR UPON ENTERIN #35368145Y | Mar 21, 2019 IN VIOLATION | $5,000 |
| Nov 27, 2018 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS.AT TIME OF INSPECTION I OBSERVED MASONRY PIECES AT EXP #1 AND #3 WERE BUILT OUT OF SOLID BRICK WHICH DOES NOT CONFORM TO APPROVED DRAWINGS.ARCHITECTUAL A #35368141R | Mar 21, 2019 IN VIOLATION | $2,343 |
| Nov 27, 2018 | Construction CLASS - 1 BC3303.7.2.FIRE EXTINGUISHERS NOT MAINTAINED AS PER NYC FIRE CODE.AT TIME OF INSPECTION OF A NEW 7 STORY BUILDIGN UNDER CONSTRUCTION I OBSERVED MULTIPLE FIRE EXTINGUISHERS THROUGHOUT THE JOBSITE WITH THE FOLLOW #35368140P | Mar 21, 2019 IN VIOLATION | $2,500 |
| Nov 27, 2018 | Construction CLASS - 1 BC3314.1.SUPPORTED SCAFFOLD DO NOT MEET CODE SPECIFICATIONS.AT TIME OFINSPECTION I OBSERVED SUPPORTED SCAFFOLD AT EXP 3 AND EXP 1 54 SIDE WITHH THE FOLLOWING PROBLEMS.PLATFORMS NOT FULLY PLANKED.-PLANKS NOT TIE #35368139H | Mar 21, 2019 IN VIOLATION | $2,500 |
| Aug 15, 2018 | Construction CLASS - 1 3301.1.2-NOTE=AT THE TIME OF MY INSPECTION OF ANACTIVE JOB SITE, I OBSERVED 3 FLAMMABLE COMPRESSED GAS TANKS IMPROPERLY STORED IN THE CELLAR.UPON REQUEST FOR FDNY PERMIT FOR FLAMMABLE COMPRESSED GAS STORAGE NON #35350981Y | Oct 4, 2018 IN VIOLATION | $2,500 |
| Aug 15, 2018 | Construction CLASS - 2 FAILURE TO PROVIDE APPROVED/ACCEPTED DESIGN DOCUMENT.AT TIME OF INSPECTION AT AN ACTIVE JOBSITE I OBSERVED CONCRETE DECORING FORMWORK IN PROGRESS AT EXP 3 SUPPORT BY SHORING RESTING ON GROUND AT CELLAR LEVEL,UP #35350983H | Oct 4, 2018 IN VIOLATION | $250 |
| Aug 15, 2018 | Construction CLASS - 1 3303.4.6-STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.AT THE TIME OF MY INSPECTION OF AN ACTIVE JOB SITE.I OBSERVED 3 COMBUSTIBLE GAS TANKS STORED IN THE CELLAR ON THE GROUND CONTRARY TO FDNY FIRE CODE.FAILUR #35350980M | Oct 4, 2018 IN VIOLATION | $2,500 |
| May 30, 2018 | Construction CLASS - 1 NO DESIGN DRAWING. AT THE TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. PLATFORM HAVE BEEN CONSTRUCTED IN 1ST FLOOR. NO DESIGN DRAWING PROVIDED FOR INSPECTION AS REQUIRED. (TWO LOCATIONS). RMDY: STOP ALL WORK AT #35331512H | Aug 2, 2018 IN VIOLATION | $625 |
| May 30, 2018 | Construction CLASS - 1 NO GUARDRAILS. AT THE TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. SOME WORKERS WAS WORKING AT JOBSITE. OBSERVED INADEQUATE GUARDRAILS WAS PROVIDED AT EXPOSURE 1 AND 3, 5TH, 6TH,7TH FLOORS AND SOME LOCATIONS #35331513J | Aug 2, 2018 IN VIOLATION | $2,500 |
| May 30, 2018 | Construction CLASS - 2 VERTICAL SAFETY NETTING SYSTEM. AT THE TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. SOME WORKERS WAS WORKING AT JOBSITE. INADEQUATE VERTICAL SAFETY NETTING HAS BEEN FOUND ON 3RD, 5TH AND 6TH FLOOR AND SOME LOCA #35331515N | Aug 2, 2018 IN VIOLATION | $625 |
| May 30, 2018 | Construction CLASS - 2 PROJECT INFO PANEL. AT THE TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. OBSERVED NO PROJECT INFORMATION AND WAS NOT POSTED ON TEH FENCE AT A HEIGHT OF 4'ABOVE THE GROUND FAILURE MAINTAIN PROJECT INFO PANEL #35331516P | Aug 2, 2018 IN VIOLATION | $625 |
| May 30, 2018 | Construction CLASS - 1 HOUSEKEEPING. AT TIME OF INSPECTION OBSERVED ACTIVE JOBSITE. DEBRIS AND CONSTRUCTION MATERIALS HAS NOT BEEN MAINTAINED ADEQUATELY AS REQUIRED. DEBRIS HAS BEEN FOUND ALONG THE PERIMETER EDGE OUTSIDE THE VERTIC #35331514L | Aug 2, 2018 IN VIOLATION | $2,500 |
| Apr 21, 2018 | Construction CLASS - 2 SEC. 3301.2 SIGNS. AT TIME OF INSPECTION OF NEW 7 STY BLDG ACTIVE JOBSITE I OBSERVED INADEQUATE & MISSING EXIT SIGNS & FLOOR SIGNS THROUGHOUT JOBSITE. REMEDY: PROVIDE/MAINTAIN ADEQUATE SIGNS. #35326757J | Nov 27, 2018 IN VIOLATION | $625 |
| Apr 21, 2018 | Construction CLASS - 1 SEC. 3306.9.12.1 REMOVAL OF MATERIAL AT TIME OF INSPECTION OF NEW 7 STY BLDG ACTIVE JOB SITE I OBSERVED AT 1ST STY DEBRIS BEING REMOVED FROMFLOORS ABOVE VIA A HOLE OPENING IN THE CEILING. I ALSO OBSERVED THE AR #35326758L | Nov 15, 2018 IN VIOLATION | $2,500 |
| Apr 21, 2018 | Construction CLASS - 1 SEC. 3301.4 INSPECTION AT TIME OF MY INSPECTION OF A NEW 7 STY BLDG ATROOF LEVEL CONSTRUCTION WORK IN PROGRESS. I OBSERVED CONCRETE EMBEDDEDSAFETY STRAPS INSTALLED 2ND STY & UP. UPON REQUEST FOR INSPECTION LOGS #35326755X | Nov 27, 2018 IN VIOLATION | $250 |
| Apr 21, 2018 | Construction CLASS - 1 SEC. 3305.3.6.1.2 RESHORES IN PROXIMITY TO ENCLOSED PERIMETERS. AT TIME OF INSPECTION OF NEW 7 STY BLDG I OBSERVED RESHORES ON LEADING EDGE AT EXP#1 & 3 AT 3RD STY & UP NOT SECURED AS REQUIRED. FAILURE TO SECUR #35326756H | Nov 27, 2018 IN VIOLATION | $625 |
| Mar 28, 2018 | Site Safety CLASS - 1 NO DESIGNATED SUPER ON SITE AS REQUIRED PER CODE. @ TIME OF INSP OF AN ACTIVE JOBSITE, OBSERVED NO SUPER WAS PRESENT & NO LOG SHEET FOR THE DAY IN THE LOG BOOK. UPON FURTHER REVIEW OF THE LOG BOOK, 1 FOUND SEVE #35318513N | Aug 9, 2018 IN VIOLATION | $1,250 |
| Jan 22, 2018 | Site Safety CLASS - 1 CONSTRUCTION SUPERINTENDENT FAILED TO PRFORM DUTIES AS PER RULE.THE FOLLOWING VIOLATING HAZARDOUS CONDITIONS WERE OBSERVED ON THIS DATE AND STOP WORK ORDER ISSUED; 1-INADEQUATE JOB SITE LOGS; 2-NO SUPERINT #35300398L | Feb 7, 2019 IN VIOLATION | $10,000 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 10, 2026 | ECB | Construction: B. C. 907.2.8. FAILURE TO PROVIDE A CLASS "1" FIRE ALARM SYSTEM FOR TRANSIENT USE AT UNIT 74 ON THE 7TH FLOOR. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. | Open |
| Aug 10, 2026 | ECB | Quality of Life: PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT RESIDENTIALPURPOSES. DEPARTMENT OF BUILDINGS RECORDS INDICATES PREMISES TO BE LEGALLY APPROVED AS A CLASS "A" MULTIPLE DWELLING. ILLEGAL OCCUPANCY NOTE | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)