3 floors · 6 apartments · 5,400 sq ft · built 1912 · class C2 · owner of record: Beyond Limits Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 16 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual boiler inspection (6 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-11 (Accepted). Agency page | Dec 31, 2026 in 65 days | 6 of 6 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 1, 2010 | Construction CLASS - 1 B101/50A/50B/50A-NO WORK PERMIT FILED W/DOB FOR THE REPLACEMENT USED BOILER/50B-WORK W/O A PERMIT 28-105.1 #32070085K | Aug 24, 2011 IN VIOLATION | $0 |
| Oct 25, 2010 | Boilers CLASS - 1 B154,51,32,6A,3B,40A,44A,38,5A,15,50A,B,C,D,E,F. 50A- DRAFT SLAT MISSING. 50D- NO LIGHTS. 50B- FLUE PIPE NEEDS SUPPORT 50C- CHIMNEY BASE CLOGGED (FUMES HAZARDOUS) 50E- NO MIXING VALVE ON COIL. 50F- PIPE SAFETY #32070083R | Dec 20, 2010 IN VIOLATION | $0 |
| May 2, 2002 | Construction Hazardous FAILURE TO MAINTAIN BUILDING HAZARDOUS FLOOR ABOVE CELLAR IS SINKING DUE TO SEVERAL BROKEN JOISTS AND ROTTED BEAMS THERE IS NO SUPPORT UNDER THE JOISTS AND BEAMS, AND THE FLOOR IS BOUNEING WHEN WALKED ON. REMED #34323175J | Jun 17, 2002 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 25, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION #11893 | DOB VIOLATION - ACTIVE |
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #06974 | DOB VIOLATION - ACTIVE |
| Jan 28, 2011 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00286 | DOB VIOLATION - ACTIVE |
| Jan 28, 2011 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00285 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #22797 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Apr 25, 2023 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Jan 28, 2011 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 28, 2011 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 22, 2023 | C | Apt 2R · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Oct 16, 2023 |
| Sep 21, 2023 | C | Apt 2R · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE KNOB ASSEMBLY ON DOOR IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Sep 27, 2023 |
| Sep 21, 2023 | C | Apt 2R · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES ON DOOR IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 5, 2023 |
| Jun 26, 2023 | B | Apt 2R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 31, 2023 |
| Jun 21, 2023 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 17, 2023 |
| Jun 21, 2023 | C | Apt 2R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jul 17, 2023 |
| Jun 17, 2020 | C | Apt 2L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER LEAK AT CEILING, SOUTH AND EAST WALL IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 23, 2020 |
| Jun 17, 2020 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT PUBLIC HALL, 1st STORY | Jun 23, 2020 |
| Jun 17, 2020 | C | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ENTIRE AREA AT OPEN SPACE, BASEMENT | Jun 23, 2020 |
| Jan 11, 2010 | B | Apt 2L · SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 15, 2010 |
| Jun 24, 2005 | C | Apt 2L · SECTION 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY ?11-06(B)(2) 1st RISER FROM NORTH AT EAST WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL IN T | Jul 20, 2005 |
| Jan 28, 2004 | C | Apt 2L · SECTION 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. CEILING, NORTH WALL, SOUTH WALL, EAST WALL, WEST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2L, 2nd STORY, 1st APA | Feb 28, 2004 |
| Jan 28, 2004 | C | Apt 2L · SECTION 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS ON A DETERIORATED SUBSURFACE THAT IS UNSTABLE OR UNSOUND USING EXCLUSIVE INTERIM CONTROLS. WEST WALL IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 28, 2004 |
| Jan 28, 2004 | C | Apt 2L · SECTION 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR IS ON A DETERIORATED SUBSURFACE - USING EXCLUSIVE INTERIM CONTROLS. CEILING, EAST WALL IN THE 5th ROOM FROM NORTH AT EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 28, 2004 |
| Nov 4, 1996 | C | Apt 3L · § 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING CENTER ROOM 3 STY WEST APT 3L MANUEL 453 8415 ER1 96030160 , SECTION '' '' | Nov 24, 1996 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)