Bronx · Block 5034 · Lot 28 · 10466

4305 Carpenter Avenue

5 floors · 41 apartments · 39,240 sq ft · built 1930 · class C1 · owner of record: Carpenter Realty Llc

25open violations
$20,250ECB/OATH penalties owed
9HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 65 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 81 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 39,240 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 186 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 186 days
Annual filing
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 430 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-19 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $20,250 owed
IssuedViolationHearingBalance
Mar 10, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, NO ACCESS, NO CERTIFICATE OF CORRECTION WAS ON FILE WITH THE DEPARTME
#39179866R
Apr 9, 2027
PENDING
$1,250
Mar 10, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. AT TIME OF INSPECTION, OBSERVED NO CONSTRUCTION OR PLUMBING PERMITS ON FILE WITH THE DEPARTMENT OF BUILDINGS. RESPONDENT FAILED TO COMPLY WITH AND
#39179867Z
Apr 9, 2027
PENDING
$2,500
Apr 15, 2025Unknown CLASS - 2
I OBSERVED IN TROUGH A 12 AWG WIRE TAPPING ON LOAD SIDE OF 400 AMPS IS UNDERSIZE AND NOT PROTECTED BY AN OVERCURRENT PROTECTION CREATING AN UNSAFE ELECTRICAL CONDITIONS., COMPLY WITH EC; FIX ALL CONDITIONS AS P
#39146184Z
Jul 18, 2025
DEFAULT
$4,000
Mar 8, 2025Construction CLASS - 1
WORK WITHOUT PERMIT. AT CELLAR LEVEL CREATED FULL HEIGHT PARTITIONS FOR 3 PIECE BATHROOM(SINK, SHOWER, TOILET) ALONG WITH WITH LIGHT FIXTURES, SWITHCES AND RECEPTACLES. REMEDY: OBTAIN PERMIT.
#35667905H
Mar 19, 2026
IN VIOLATION
$0
Mar 8, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT APT #1F THE BATHROOM FLOOR PARTIALLY COLLAPSED INTO CELLAR, LEAVING BRICKS AND DEBRIS DOWNSTAIRS. REMEDY: REPAIR AND/OR REPLACE.
#35667906J
Mar 19, 2026
IN VIOLATION
$12,500
DOB (2)
IssuedViolationStatus
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2002764
DOB VIOLATION - ACTIVE
Jan 10, 1991CONSTRUCTION

#10J1VW
VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
HPD (15) · C 9 · B 4 · A 2
IssuedClassViolationCorrect by
Jul 23, 2026BApt 2F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT NORTH AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHAug 27, 2026
Jul 23, 2026AApt 2F · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONVERTED FROM GAS TO ELECTRIC RANGE PLEASE REFER FOR COMPREHENSIVE. IN THE KITCHEN LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH Oct 26, 2026
Jul 23, 2026BApt 2F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHAug 27, 2026
Jul 23, 2026AApt 2F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILING, WALLS, DOOR, TRIM AND INSIDE CLOSETS IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOct 26, 2026
Oct 24, 2025CApt 4E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 15 SQ FT AT WEST WALL APPROX 5 SQ FT AT SOUTH WALL APPROX 5 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 16602802 ISSUED 07-JAN-24 HAS BEENov 19, 2025
Mar 24, 2025CApt 5H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stApr 17, 2025
Mar 24, 2025CApt 5H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stApr 17, 2025
Mar 24, 2025CApt 5H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM SOUTH AT WEST WALL DOOR FRAME IN THE PRIVATE HALLWAY LOCATED AT APT 5HApr 17, 2025
Mar 24, 2025CApt 5H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stApr 17, 2025
Mar 24, 2025CApt 5H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 5H, 6th STORY, 2nd Apr 17, 2025
Aug 26, 2024BApt 5F · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30 SQ FT ON CEILING, NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 5F, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'', AT NORTHSep 30, 2024
Jul 24, 2024CApt 4H · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO GAS AT RANGE IN THE KITCHEN LOCATED AT APT 4H, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EFGH'', AT NORTHJul 30, 2024
Jul 24, 2024CApt 2F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES RANGE IN THE KITCHEN LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH''Jul 30, 2024
Apr 24, 2023BApt 1H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL 10 SQ.FT IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHMay 29, 2023
Jan 27, 2023CApt 4F · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AFeb 20, 2023

Issued in the last 120 days

DateSourceWhatNow
Jul 23, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT NORTH AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOpen
Jul 23, 2026HPD A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONVERTED FROM GAS TO ELECTRIC RANGE PLEASE REFER FOR COMPREHENSIVE. IN THE KITCHEN LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH Open
Jul 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE BATHROOM LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOpen
Jul 23, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL CEILING, WALLS, DOOR, TRIM AND INSIDE CLOSETS IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT SOUTHOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 4:24 PM ET. BBL 2050340028.