8 floors · 17,449 sq ft · built 2023 · class H3 · owner of record: 430 East 188th St Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 827 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 28, 2026 | Construction CLASS - 1 OBSERVED 8 STORY COMPLETE OCCUPIED NEW BUILDING. UPON REVIEW OF DEPARTMENT RECORDS THE JOBSITE IS ON A STOP WORK ORDER UNDER COMPLAINT #2387307. THE SWO WAS ISSUED 5-1-2024 BY BADGE #3324 STATING NO WORK ALLOW #39561209Y | Jan 15, 2027 PENDING | $10,000 |
| Sep 25, 2024 | Construction CLASS - 2 ATOI OBSERVED CONSTRUCTION FENCE IN PLACE AT EXPOSURE 1 WITHOUT ACTIVE PERMIT. FENCE PERMIT# X00609499-I1-FN EXPIRED 02/01/2024, RENEW PERMIT #39125808P | Nov 29, 2024 STIPULATION/IN-VIO | $630 |
| Mar 6, 2024 | Unknown CLASS - 1 OBSERVED SAME CONDITION AS IN VIOLATION #: 39524777J FOR FAILURE PROTECT ALL PUBLICLY ACCESSIBLE SPACES ON THE ADJOINING PROPERTY BY PROVIDING OVERHEAD PROTECTION AT EXPOSURE 2 FOR AREA AT REAR OF ADJACENT PROP #39526375X | Mar 25, 2025 DEFAULT | $6,875 |
| Feb 29, 2024 | Construction CLASS - 2 OBSERVE MAKESHIFT CATCHALL MADE WOOD COMPONENTS EXP2,OBSERVED FREESTANDING MASON FRAME SUPPORT 6 FOOT FRAMES SCAFFOLD EXP1,GC FAILED PROVIDE DESIGN DRAWINGS PER BC3301.6 HAZARD UNKNOWN COMPLIANCE TO MANUFACTURE #39526025X | Apr 8, 2025 DEFAULT | $6,250 |
| Feb 29, 2024 | Unknown CLASS - 2 8 STORY BUILDING TOP OUT OBSERVED ELEVATOR SHAFT MISSING HOIST AND NO TEMPORARY HOIST IN PLACE,BC3303.12 STIPULATES HOIST REQUIRED FOR BUILDING HEIGHT MORE THAN 75FEET OR VERT DISTANCE MORE THAN 7 STORIES HAZAR #39526024Y | Oct 15, 2026 IN VIOLATION | $2,500 |
| Jan 11, 2024 | Unknown CLASS - 2 BC 3303.2.4: SANITARY FACILITIES- AT TIME OF INSPECTION I OBSERVED ACTIVE JOBSITE WITH 2 POT A JOHNS FOR 20 MALE WORKERS AND 2 FEMALE WORKERS CREATING A HEALTH HAZARD TO WORKERS AND PERSONS USING FACILITIES, AL #39524781M | Jan 7, 2025 IN VIOLATION | $0 |
| Jan 11, 2024 | Unknown CLASS - 2 BC 3303.4.5.2 MATERIAL STORAGE: AT TIME OF INSPECTION I OBSERVED CONSTRUCTION MATERIAL STORED WITHIN 5 FEET FROM LEADING EDGE AT EXPOSURE 2 CREATING HAZARDOUS CONDITION OF POTENTIAL DISLODGEMENT OF MATERIAL AN #39524780K | Jan 7, 2025 IN VIOLATION | $0 |
| Jan 11, 2024 | Unknown CLASS - 2 BC 3301.2 HANDRAILS- AT TIME OF INSPECTION I OBSERVED MISSING HANDRAILS AT PERMANENT STAIRS 7 & 8 STORY CREATING A HAZARD FOR WORKERS AND PERSONS USING STAIRS HAVING NOTHING TO GRAB ONTO IN CASE OF A FALLING SI #39524778L | Jan 7, 2025 IN VIOLATION | $0 |
| Jan 11, 2024 | Unknown CLASS - 1 BC 3309.1 OVERHEAD PROTECTION: AT TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION WORK IN PROGRESS AT NEW 8 STORY BUILDING. I OBSERVED REAR YARD OF ADJACENT PROPERTY AT EXPOSURE 2 DID NOT HAVE ANY OVERHEAD #39524777J | Jan 7, 2025 IN VIOLATION | $0 |
| Jan 11, 2024 | Construction CLASS - 1 BC 28-105.1: WORK WITHOUT A PERMIT: AT TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION WORK IN PROGRESS BUILDING AT 8TH STORY UPON SEARCH IN DOB NOW AND BIS SYSTEMS BOTH SHOW PERMIT APPROVED BUT NOT ISSUED. S #39524761P | Jan 7, 2025 IN VIOLATION | $0 |
| Jan 11, 2024 | Unknown CLASS - 2 BC 3308.5 VERTICAL NETTING: AT TIME OF INSPECTION I OBSERVED VERTICAL NETTING INADEQUATELY MAINTAINED WITH LARGE GAPS ALLOWING MATERIAL AND OR DEBRIS TO FALL OFF JOBSITE AND CAUSE INJURY AND OR PROPERTY DAMAGE. #39524779N | Jan 7, 2025 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 11, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00386 | DOB VIOLATION - ACTIVE |
| Apr 17, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00064 | DOB VIOLATION - ACTIVE |
| Mar 20, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00063 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 11, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 17, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 20, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 28, 2026 | ECB | Construction: OBSERVED 8 STORY COMPLETE OCCUPIED NEW BUILDING. UPON REVIEW OF DEPARTMENT RECORDS THE JOBSITE IS ON A STOP WORK ORDER UNDER COMPLAINT #2387307. THE SWO WAS ISSUED 5-1-2024 BY BADGE #3324 STATING NO WORK ALLOW | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 3:22 PM ET. BBL 2030410037.