Bronx · Block 3041 · Lot 37 · 10458

430 East 188 Street

8 floors · 17,449 sq ft · built 2023 · class H3 · owner of record: 430 East 188th St Inc

17open violations
$26,255ECB/OATH penalties owed
0HPD class C (immediately hazardous)
44dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 827 days
Filing window not open yet

Open violations

ECB / OATH (11) · $26,255 owed
IssuedViolationHearingBalance
Oct 28, 2026Construction CLASS - 1
OBSERVED 8 STORY COMPLETE OCCUPIED NEW BUILDING. UPON REVIEW OF DEPARTMENT RECORDS THE JOBSITE IS ON A STOP WORK ORDER UNDER COMPLAINT #2387307. THE SWO WAS ISSUED 5-1-2024 BY BADGE #3324 STATING NO WORK ALLOW
#39561209Y
Jan 15, 2027
PENDING
$10,000
Sep 25, 2024Construction CLASS - 2
ATOI OBSERVED CONSTRUCTION FENCE IN PLACE AT EXPOSURE 1 WITHOUT ACTIVE PERMIT. FENCE PERMIT# X00609499-I1-FN EXPIRED 02/01/2024, RENEW PERMIT
#39125808P
Nov 29, 2024
STIPULATION/IN-VIO
$630
Mar 6, 2024Unknown CLASS - 1
OBSERVED SAME CONDITION AS IN VIOLATION #: 39524777J FOR FAILURE PROTECT ALL PUBLICLY ACCESSIBLE SPACES ON THE ADJOINING PROPERTY BY PROVIDING OVERHEAD PROTECTION AT EXPOSURE 2 FOR AREA AT REAR OF ADJACENT PROP
#39526375X
Mar 25, 2025
DEFAULT
$6,875
Feb 29, 2024Construction CLASS - 2
OBSERVE MAKESHIFT CATCHALL MADE WOOD COMPONENTS EXP2,OBSERVED FREESTANDING MASON FRAME SUPPORT 6 FOOT FRAMES SCAFFOLD EXP1,GC FAILED PROVIDE DESIGN DRAWINGS PER BC3301.6 HAZARD UNKNOWN COMPLIANCE TO MANUFACTURE
#39526025X
Apr 8, 2025
DEFAULT
$6,250
Feb 29, 2024Unknown CLASS - 2
8 STORY BUILDING TOP OUT OBSERVED ELEVATOR SHAFT MISSING HOIST AND NO TEMPORARY HOIST IN PLACE,BC3303.12 STIPULATES HOIST REQUIRED FOR BUILDING HEIGHT MORE THAN 75FEET OR VERT DISTANCE MORE THAN 7 STORIES HAZAR
#39526024Y
Oct 15, 2026
IN VIOLATION
$2,500
Jan 11, 2024Unknown CLASS - 2
BC 3303.2.4: SANITARY FACILITIES- AT TIME OF INSPECTION I OBSERVED ACTIVE JOBSITE WITH 2 POT A JOHNS FOR 20 MALE WORKERS AND 2 FEMALE WORKERS CREATING A HEALTH HAZARD TO WORKERS AND PERSONS USING FACILITIES, AL
#39524781M
Jan 7, 2025
IN VIOLATION
$0
Jan 11, 2024Unknown CLASS - 2
BC 3303.4.5.2 MATERIAL STORAGE: AT TIME OF INSPECTION I OBSERVED CONSTRUCTION MATERIAL STORED WITHIN 5 FEET FROM LEADING EDGE AT EXPOSURE 2 CREATING HAZARDOUS CONDITION OF POTENTIAL DISLODGEMENT OF MATERIAL AN
#39524780K
Jan 7, 2025
IN VIOLATION
$0
Jan 11, 2024Unknown CLASS - 2
BC 3301.2 HANDRAILS- AT TIME OF INSPECTION I OBSERVED MISSING HANDRAILS AT PERMANENT STAIRS 7 & 8 STORY CREATING A HAZARD FOR WORKERS AND PERSONS USING STAIRS HAVING NOTHING TO GRAB ONTO IN CASE OF A FALLING SI
#39524778L
Jan 7, 2025
IN VIOLATION
$0
Jan 11, 2024Unknown CLASS - 1
BC 3309.1 OVERHEAD PROTECTION: AT TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION WORK IN PROGRESS AT NEW 8 STORY BUILDING. I OBSERVED REAR YARD OF ADJACENT PROPERTY AT EXPOSURE 2 DID NOT HAVE ANY OVERHEAD
#39524777J
Jan 7, 2025
IN VIOLATION
$0
Jan 11, 2024Construction CLASS - 1
BC 28-105.1: WORK WITHOUT A PERMIT: AT TIME OF INSPECTION I OBSERVED ACTIVE CONSTRUCTION WORK IN PROGRESS BUILDING AT 8TH STORY UPON SEARCH IN DOB NOW AND BIS SYSTEMS BOTH SHOW PERMIT APPROVED BUT NOT ISSUED. S
#39524761P
Jan 7, 2025
IN VIOLATION
$0
Jan 11, 2024Unknown CLASS - 2
BC 3308.5 VERTICAL NETTING: AT TIME OF INSPECTION I OBSERVED VERTICAL NETTING INADEQUATELY MAINTAINED WITH LARGE GAPS ALLOWING MATERIAL AND OR DEBRIS TO FALL OFF JOBSITE AND CAUSE INJURY AND OR PROPERTY DAMAGE.
#39524779N
Jan 7, 2025
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00386
DOB VIOLATION - ACTIVE
Apr 17, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00064
DOB VIOLATION - ACTIVE
Mar 20, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00063
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Apr 17, 2024AEUHAZ FTC-AEU-HAZ
Active
Mar 20, 2024AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 28, 2026ECBConstruction: OBSERVED 8 STORY COMPLETE OCCUPIED NEW BUILDING. UPON REVIEW OF DEPARTMENT RECORDS THE JOBSITE IS ON A STOP WORK ORDER UNDER COMPLAINT #2387307. THE SWO WAS ISSUED 5-1-2024 BY BADGE #3324 STATING NO WORK ALLOWOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 3:22 PM ET. BBL 2030410037.

Look up another building