Manhattan · Block 1263 · Lot 12 · 10036

43 West 47 Street

5 floors · 10,875 sq ft · built 1920 · class K2 · owner of record: 43 West 47th Realtycorp.

23open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1143dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1143 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-29 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
May 17, 2017Boilers CLASS - 1
5B,6A,7D,38,15,50,19A,34B,32A,34B,36. 50-STORAGE AND DEBRIS IN BOILERROOM *CORRECT ALL HAZARDOUS CONDITIONS IMMEDIATELY AND CALL DOB 212- 393-2784 TO LIFT CEASE USE ORDER*
#32088605K
Jul 6, 2017
DEFAULT
$0
May 17, 2017Boilers CLASS - 1
51 FLUE CORRODED AND HAS HOLES AND INCORRECT SUPPORT. *CORRECT ALL HAZARDOUS CONDITIONS IMMEDIATELY AND CALL DOB 212-393-2784 TO LIFT CEASE USE ORDER.*
#32088607Y
Jul 6, 2017
DEFAULT
$0
May 17, 2017Boilers CLASS - 1
51 FLUE CORRODED AND HAS HOLES AND NOT INTO CHIMNEY ABOVE LARGER FLUE*CORRECT ALL HAZARDOUS CONDITIONS IMMEDIATELY AND CALL DOB 212-393- 2784 TO LIFT CEASE USE ORDER.
#32088606M
Jul 6, 2017
DEFAULT
$0
Jul 28, 2009Elevators CLASS - 2
34O02,34B04,40B07.40B-PROVIDE VENTILATION AS PER CODE.
#38205108H
Sep 17, 2009
STIPULATION/IN-VIO
$0
DOB (4)
IssuedViolationStatus
Aug 9, 2017FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00077
DOB VIOLATION - ACTIVE
Aug 9, 2017FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00078
DOB VIOLATION - ACTIVE
Aug 9, 2017FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00076
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#00930
DOB VIOLATION - ACTIVE
DOB NOW Safety (15)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 5)
Active
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 9, 2017AEUHAZ FTC-AEU-HAZ
Active
Aug 9, 2017AEUHAZ FTC-AEU-HAZ
Active
Aug 9, 2017AEUHAZ FTC-AEU-HAZ
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of CorrectionOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:57 AM ET. BBL 1012630012.