Manhattan · Block 1373 · Lot 7502 · 10044

425 Main Street

16 floors · 216 apartments · 195,990 sq ft · built 2006 · class RM · owner of record: Unavailable Owner

1open violations
$17,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 67 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 195,990 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 850 days
Filing window not open yet
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1373). Agency page

Dec 31, 2033
in 2624 days
Next due 2033
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $17,500 owed
IssuedViolationHearingBalance
Sep 22, 2025Construction CLASS - 2
OBSERVED SUSPENDED SCAFFOLDS AT EXP#4 INSTALLED CONTRARY TO PLANS-ANCHORAGE ANGLE NOT FLUSH WITH WALL(SPACE,WASHERS BETWEEN ANGLE AND WALL/ANGLE FOR LIFELINE/TIEBACK INSTALLED IN WRONG DIRECTION/PULL OF LIFELI
#39545177Z
Dec 1, 2026
DEFAULT
$3,125
Sep 22, 2025Construction CLASS - 2
AT THE TIME OF MY INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT 3XP#1 FROM GROUND TO SETBACK AND ON SETBACK -UPON CHECKING SITE SAFETYPLAN NO SUPPORTED SCAFFOLDS INDICATED ON PLANS-STOP ALL USE OF SUPPORT
#39545184R
Dec 1, 2026
DEFAULT
$3,125
Sep 22, 2025Construction CLASS - 2
AT THE TIME OF MY INSPECTION OBSERVED SUSPENDED SCAFFOLDS AT EXP#1 AND 4-WITH LINES IN MOTORS(PREVIOUS WORK ON FACADE OBSERVED)-UPON ASKING FOREMAN FOR PRE SHIFT INSPECTION FOR SUSPENDED SCAFFOLD,SUPPORTED SCAF
#39545178K
Jun 9, 2026
IN VIOLATION
$1,250
Sep 22, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED SUSPENDED SCAFFOLD LANDED ON EDGE OF CANOPY ABOVE MAIN ENTRANCE -APROX 2/3 FEET FROM END OF CANOPY TO GARDEN BED-NO SIDEWALK SHED PROVIDED-PUBLIC ACCESSIBLE -STOP ALL WORK
#39545185Z
Jun 9, 2026
IN VIOLATION
$10,000
DOB (1)
IssuedViolationStatus
Oct 9, 2009ELEVATOR

#9011/315427
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 12:57 AM ET. BBL 1013737502.

Look up another building