5 floors · 10 apartments · 8,345 sq ft · built 1930 · class C1 · owner of record: 424 E 83rd St Operating, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-24 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 10, 2006 | Boilers Hazardous B4B/41/50/50A/50B/50C/50D. 50- OIL LEAKING UNDER OIL BURNER & BOILER. 50A- INADEQUATE FRESH AIR TO ENCLOSED BOILER RM 12 X 12 MIM. W/FIRE DAMPER. 50B- HOLES IN BOILER RM CEILING. 50C- SOOT ON TOP OF BOILER & IN #32049572L | Apr 26, 2007 DEFAULT | $0 |
| Apr 7, 2005 | Boilers Hazardous 3B/50/51 50-HAZARDOUS EXTREME PULSATION FROM THE BOILER 3B-HAZARDOUS SMOKING. #32047501P | Apr 26, 2007 DEFAULT | $0 |
| Apr 15, 2004 | Plumbing Non-Hazardous PLUMBING WORK WITHOUT A PERMIT-HAZARDOUS.LOCATION-BASEMENT.INSTALLED GAS FIRED HOT WATER HEATER AND STORAGE TANK.OPENED ARA APPLICATION #100523088 PERMITTED GAS PIPING REPLACEMENT ONLY.REMEDY:OBTAIN A PERMIT IF #34426479K | Jun 3, 2004 IN VIOLATION | $0 |
| Apr 15, 2004 | Plumbing Non-Hazardous FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.LOCATION:BASEMENT.UTILIZING GAS FOR GAS FIRED HOT WATER HEATER WITHOUT NYC DOB GAS AUTHORIZATION.AS PER DOB RECORD NO REQUIRED GAS TEST WAS PERFORMED.GAS #34426480H | Jun 3, 2004 IN VIOLATION | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 12, 2025 | B | Apt 4E · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4E, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 19, 2025 |
| Feb 12, 2025 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT BULKHEAD DOOR, ROOF. | Feb 26, 2025 |
| Feb 10, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY | Mar 17, 2025 |
| Feb 10, 2025 | C | Apt 2W · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2W, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 24, 2025 |
| Jul 28, 2023 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING , 1st STORY | Aug 3, 2023 |
| Jun 17, 2013 | B | Apt 2W · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO FIRE ESCAPE IN THE 5th ROOM FROM NORTH LOCATED AT APT 2W, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 22, 2013 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 2:44 PM ET. BBL 1015620034.