5 floors · 16 apartments · 16,644 sq ft · built 1914 · class C1 · owner of record: 423 57th Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-19 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Dec 31, 2009 | LOW PRESSURE BOILER #09974 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #34288 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 1, 2022 | B | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT FRONT YARD | Dec 6, 2022 |
| Nov 1, 2022 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS INSTALLED AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Dec 6, 2022 |
| Nov 1, 2022 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS ON 2ND STORY BALCONY STACK FROM WEST AT SOUTH AT BUILDING FRONT AT FIRE ESCAPE | Dec 6, 2022 |
| Mar 28, 2022 | B | Apt A · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH COUNTERBALANCE AT 1ST WINDOW FROM SOUTH AT WEST IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | May 2, 2022 |
| May 8, 2017 | B | Apt A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 12, 2017 |
| May 8, 2017 | B | Apt A · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS IN ENTRANCE LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 12, 2017 |
| May 8, 2017 | B | Apt A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE IN NORTH 3 ROOM LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 12, 2017 |
| May 8, 2017 | B | Apt A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING LOCATED AT APT A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 12, 2017 |
| Jul 29, 2016 | A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS FROM 1ST. STORY TO BULKHEAD AT PUBLIC HALL | Nov 1, 2016 |
| Jul 31, 2014 | C | Apt 2D · SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 0; WG TO REPLACE = 0; WG TO REPAIR = 4; INSTALL ONE WAY SCREWS IN THE ENTIRE APARTMENT LOCATED | Aug 28, 2014 |
| Jul 16, 2014 | C | Apt 2D · SECTION 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 3rd STORY, 1 | Aug 13, 2014 |
| Sep 11, 2013 | A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WEST WALL AT BULKHEAD AT PUBLIC HALL STAIRS, 4th STORY | Dec 15, 2013 |
| Sep 11, 2013 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING / PLASTER / CEILING AND WEST WALL AT BULKHEAD AT PUBLIC HALL STAIRS, 4th STORY | Oct 16, 2013 |
| Jun 24, 2013 | B | Apt 2C · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL-BUZZER/INTERCOM IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jul 29, 2013 |
| Jun 24, 2013 | B | Apt 3B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL-BUZZER/INTERCOM IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 29, 2013 |
| Feb 16, 2012 | B | Apt 3B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT BUILDING ENTRANCE DOOR IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 22, 2012 |
| Jul 5, 2011 | B | Apt 3B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL BUZZER SYSTEM FROM ENTRANCE DOOR TO BUILDING TO APARTMENT DOOR IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 9, 2011 |
| May 19, 2011 | B | Apt 1D · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1D, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 23, 2011 |
| May 19, 2011 | B | Apt 1D · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERCOM PANEL IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 23, 2011 |
| Nov 3, 2010 | B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRES (NOT SPARKING) CEILING THROUGH OUT AT CELLAR | Dec 8, 2010 |
| Jun 7, 2010 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 2ND UP AND 2ND FROM INTERMIDIATE LANDING MARBLE TREADS AT PUBLIC HALL STAIRS, 1st STORY | Jul 12, 2010 |
| Dec 19, 2008 | B | Apt 2C · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 23, 2009 |
| May 24, 2005 | B | Apt 1A · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE IN THE FOYER LOCATED AT APT 1A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 3, 2005 |