Brooklyn · Block 747 · Lot 67 · 11220

423 46 Street

3 floors · 6 apartments · 2,928 sq ft · built 1914 · class C2 · owner of record: Sackoor Ttee, Kaladeen N

52open violations
$0ECB/OATH penalties owed
6HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-10-16 (Accepted). Agency page

Dec 31, 2026
in 68 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1164 days
Next cycle year 2029

Open violations

ECB / OATH (0)

None open.

DOB (5)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#43361
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#07240
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#12055
DOB VIOLATION - ACTIVE
May 4, 1998LOCAL LAW 62/91 - BOILERS

#17197
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#17739
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
May 4, 1998Boiler LL6291
Active
Feb 10, 1997Boiler LL6291
Active
HPD (40) · C 6 · B 22 · A 12
IssuedClassViolationCorrect by
May 1, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 4, 2026
Jun 6, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 9, 2025
Apr 8, 2024A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 12, 2024
Mar 20, 2023A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jun 23, 2023
Feb 22, 2022A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.May 28, 2022
Apr 6, 2021A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 10, 2021
Nov 14, 2013BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINIMUM OF 100 WATTS OF INCANDESCENT LIGHT IS REQUIRED (LIGHT FIXTURE PRESENT)Dec 19, 2013
Jun 18, 2008BApt 3R · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK BATHROOM 3 STY APT 3R. LOCATED AT APT 3RJul 23, 2008
Jun 18, 2008BApt 3R · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CELOTEX CLG BATHROOM 3 STY APT 3R. LOCATED AT APT 3RJul 23, 2008
Jun 18, 2008BApt 3R · D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRICAL WALL OUTLET REAR ROOM 3 STY APT 3R. LOCATED AT APT 3RJul 23, 2008
Jun 18, 2008BApt 1R · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS & CLGS BATHROOM 1 STY APT 1R. LOCATED AT APT 1RJul 23, 2008
Jun 18, 2008BApt 1R · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CLG BATHROOM 1 STY APT 1R. LOCATED AT APT 1RJul 23, 2008
Jun 18, 2008BD26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 STY REAR STACK R48.Jul 23, 2008
Jun 18, 2008BD26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS FRONT NIGHT INSPECTION.Jul 23, 2008
Jul 28, 2006ASECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER FRONT FIRE ESCAPE FRONT OF BLDGNov 24, 2006
Jul 28, 2006ASECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL STYS WALLS CEILING THRU OUT PUBLIC HALL.Nov 24, 2006
Jul 28, 2006ASECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSINGNov 24, 2006
Jul 28, 2006ASECTION 27-2048 ADM CODE PAINT OR POST A SIGN INDICATING FLOORS ON WALLS AT OR NEAR STAIRS ALL STYS PUBLIC HALL.Nov 24, 2006
Jul 28, 2006AApt 5 · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTHNov 24, 2006
Jul 28, 2006AApt 5 · SECTION 27-2005 ADM CODE REFIT LOWER WINDOW SASH IN THE KITCHEN LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTHNov 24, 2006
Jun 2, 2003BApt 5 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE FOYER LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTHJul 12, 2003
Jun 2, 2003BApt 5 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTHJul 12, 2003
Jun 2, 2003BApt 5 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 5, 3rd STORY, APARTMENT AT NORTHJul 12, 2003
Jun 2, 2003BApt 5 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE AT ENTIRE APARTMENT, 2nd STORY, APARTMENTJul 12, 2003
May 27, 2003BApt 1 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING. IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORYJul 6, 2003
May 27, 2003BApt 1 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING. IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORYJul 6, 2003
May 25, 1999BSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE 2 STY STRINGER TO BALCONY REAR YARD ER1.Jul 12, 1999
May 25, 1999BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 200 WATTSJul 12, 1999
May 25, 1999BSECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES ALL STYS REAR YARD.Jul 12, 1999
May 25, 1999BSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSTRUCTION MATERIAL CENTER ROOF.Jul 12, 1999
May 25, 1999CSECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1 STY PUBLIC HALL AND ON BOILER ROOOM DOOR CELLAR.Jun 14, 1999
May 25, 1999BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED CEILING FRONT AND REAR CELLAR.Jul 12, 1999
May 25, 1999BSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE WALL BRACES TO GOOSENECK LADDER ROOF REAR ER1.Jul 12, 1999
Feb 2, 1999CApt 1 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MILDEW COVERING WALLS OF BATHROOM BASEMENT APT 1 ER1 , SECTION '' ''Feb 22, 1999
Feb 2, 1999CApt 1 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED CEILING WATER LEAKS INSIDE KITCHEN CLOSET BASEMENT APT 1 ER1 , SECTION '' ''Feb 22, 1999
Apr 14, 1998CSECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT WALLS AND CEILING AND STEAM RISER BATHROOM BSMT STY APT ALVAREZ 718 438 0651 ER1 98009955.May 4, 1998
Jan 27, 1998BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPALLING BROWNSTONE BASEMENT VESTIBULE CEILING.Mar 16, 1998
Jan 27, 1998CApt 1 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT HEAT RISER AND WINDOW CASING BATHROOM BASEMENT APT 1 ER1 98001106. LOCATED AT APT 1Feb 16, 1998
Jan 27, 1998CApt 1 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT AND OR PLASTER CEILING SOUTH WEST AND EAST WALLS BATHROOM BASEMENT APT 1 ALVAREZ 438 0651 ER1 98001106. LOCATED AT APT 1Feb 16, 1998
Oct 29, 1996BSECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BELLS AT BLDG FRONTDec 16, 1996

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 5:29 PM ET. BBL 3007470067.