2 floors · 7,972 sq ft · built 1930 · class O7 · owner of record: Fsfhp Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 57 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2018-11-07 (Accepted). Agency page | Dec 31, 2026 in 57 days | 1 of 1 without an accepted 2026 report yet |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 422 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 23, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE INSTALLED AROUND JOBSITE PERIMETER NOT MAINTAINED AS PER CODE, AFTER REVIEW OF BIS & DEPARTMENT OF BUILDINGS (DOB) SYSTEM RECORDS CONFIRMED THAT FENCE PERM #39560957P | Jan 6, 2027 PENDING | $1,000 |
| Sep 21, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF REINSPECRION FOR VIO#39159001J OBSERVED, A 2 STORY VACANT BRICK BUILDING, 2ND FLOOR, LOSE AND MISSING SIDINGS, ROOF SAGGING, MISSING SHINGLES, R #39204881R | Dec 2, 2026 ADMIT/IN-VIO | $0 |
| Sep 2, 2025 | Construction CLASS - 1 NOTED: 2 STORY VACANT BRICK BUILDING, 2ND FLOOR, LOSE AND MISSING SIDINGS, ROOF SAGGING, MISSING SHINGLES, ROOF PARTIAL COLLAPSE, MISSING LOSE AND HANGING SOFFITS CLOSING OFF THE UNDER LAYER OF THE ROOF OVERHAN #39159001J | Nov 12, 2025 ADMIT/IN-VIO | $0 |
| May 28, 2025 | Boilers CLASS - 2 FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000090351N0001 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT. 1RCNY 103-01(D)(1) REQUIRES THAT AN ANNUAL INSPECTION REPORT FO #37035270K | Dec 3, 2026 DEFAULT | $3,125 |
| Issued | Violation | Status |
|---|---|---|
| Oct 22, 2025 | CONSTRUCTION VACATE ORDER-OBSVD CRACKED GLASS WINDOW, MISSING BRICKS AND MORTAR, OPEN ROOF AND LOOSE BRICKS AT RISK OF FALLING AT PARAPET LEVEL PARAPET BRICKS AT RISK OF COLLAPSE. VACATE ENTIRE BLDG #PI31205TC | DOB VIOLATION - ACTIVE |
| Oct 22, 2025 | CONSTRUCTION EMERGENCY WORK ORDER-IMMED HAZ CONDITION-THE PARAPET ON EXP2 HAD PARTIALLY COLLAPSED,THE REMAINING PARAPET IS LOOSE,UNSTABLE AND AT RISK OF COLLAPSE. THE IS MISSING BRICKS,MORTAR & LOOSE BRICKS AT THE PARAPET LEVEL. OWNER TO IMMED RETAIN NYSPE & DOB REG GC TO HAND REMOVE LOOSE PARAPET BRICKS,INSTALL #PI31204TC | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #27177 | DOB VIOLATION - ACTIVE |
| Feb 16, 2023 | UNSAFE BUILDINGS #3808/23 | DOB VIOLATION |
| Issued | Violation | Status |
|---|---|---|
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 23, 2026 | ECB | Construction: AT THE TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE INSTALLED AROUND JOBSITE PERIMETER NOT MAINTAINED AS PER CODE, AFTER REVIEW OF BIS & DEPARTMENT OF BUILDINGS (DOB) SYSTEM RECORDS CONFIRMED THAT FENCE PERM | Open |
| Sep 21, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF REINSPECRION FOR VIO#39159001J OBSERVED, A 2 STORY VACANT BRICK BUILDING, 2ND FLOOR, LOSE AND MISSING SIDINGS, ROOF SAGGING, MISSING SHINGLES, R | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 9:35 PM ET. BBL 3055960049.