Brooklyn · Block 5596 · Lot 49 · 11219

4218 Ft Hamilton Parkway

2 floors · 7,972 sq ft · built 1930 · class O7 · owner of record: Fsfhp Owner Llc

10open violations
$4,125ECB/OATH penalties owed
0HPD class C (immediately hazardous)
57dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2018-11-07 (Accepted). Agency page

Dec 31, 2026
in 57 days
1 of 1 without an accepted 2026 report yet
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 422 days
Next cycle year 2027

Open violations

ECB / OATH (4) · $4,125 owed
IssuedViolationHearingBalance
Oct 23, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE INSTALLED AROUND JOBSITE PERIMETER NOT MAINTAINED AS PER CODE, AFTER REVIEW OF BIS & DEPARTMENT OF BUILDINGS (DOB) SYSTEM RECORDS CONFIRMED THAT FENCE PERM
#39560957P
Jan 6, 2027
PENDING
$1,000
Sep 21, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF REINSPECRION FOR VIO#39159001J OBSERVED, A 2 STORY VACANT BRICK BUILDING, 2ND FLOOR, LOSE AND MISSING SIDINGS, ROOF SAGGING, MISSING SHINGLES, R
#39204881R
Dec 2, 2026
ADMIT/IN-VIO
$0
Sep 2, 2025Construction CLASS - 1
NOTED: 2 STORY VACANT BRICK BUILDING, 2ND FLOOR, LOSE AND MISSING SIDINGS, ROOF SAGGING, MISSING SHINGLES, ROOF PARTIAL COLLAPSE, MISSING LOSE AND HANGING SOFFITS CLOSING OFF THE UNDER LAYER OF THE ROOF OVERHAN
#39159001J
Nov 12, 2025
ADMIT/IN-VIO
$0
May 28, 2025Boilers CLASS - 2
FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000090351N0001 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT. 1RCNY 103-01(D)(1) REQUIRES THAT AN ANNUAL INSPECTION REPORT FO
#37035270K
Dec 3, 2026
DEFAULT
$3,125
DOB (4)
IssuedViolationStatus
Oct 22, 2025CONSTRUCTION
VACATE ORDER-OBSVD CRACKED GLASS WINDOW, MISSING BRICKS AND MORTAR, OPEN ROOF AND LOOSE BRICKS AT RISK OF FALLING AT PARAPET LEVEL PARAPET BRICKS AT RISK OF COLLAPSE. VACATE ENTIRE BLDG
#PI31205TC
DOB VIOLATION - ACTIVE
Oct 22, 2025CONSTRUCTION
EMERGENCY WORK ORDER-IMMED HAZ CONDITION-THE PARAPET ON EXP2 HAD PARTIALLY COLLAPSED,THE REMAINING PARAPET IS LOOSE,UNSTABLE AND AT RISK OF COLLAPSE. THE IS MISSING BRICKS,MORTAR & LOOSE BRICKS AT THE PARAPET LEVEL. OWNER TO IMMED RETAIN NYSPE & DOB REG GC TO HAND REMOVE LOOSE PARAPET BRICKS,INSTALL
#PI31204TC
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#27177
DOB VIOLATION - ACTIVE
Feb 16, 2023UNSAFE BUILDINGS

#3808/23
DOB VIOLATION
DOB NOW Safety (2)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 23, 2026ECBConstruction: AT THE TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE INSTALLED AROUND JOBSITE PERIMETER NOT MAINTAINED AS PER CODE, AFTER REVIEW OF BIS & DEPARTMENT OF BUILDINGS (DOB) SYSTEM RECORDS CONFIRMED THAT FENCE PERMOpen
Sep 21, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF REINSPECRION FOR VIO#39159001J OBSERVED, A 2 STORY VACANT BRICK BUILDING, 2ND FLOOR, LOSE AND MISSING SIDINGS, ROOF SAGGING, MISSING SHINGLES, ROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 9:35 PM ET. BBL 3055960049.