Brooklyn · Block 8542 · Lot 8 · 11234

4201 Avenue U

1 floors · 3,000 sq ft · built 1972 · class K1 · owner of record: Ai Business Operations, Llc

6open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1164dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 18 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1164 days
Next cycle year 2029

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Dec 23, 2014Unknown CLASS - 2
LUMINAIRES(FIXTURES)& LAMP HOLDERS NOT INSTALLED IN AN APPROVED MANNER. AT 1:45PM OBSERVED THAT FLURESENT FIXTURES TRU-OUT STORE IS NOT INSTALLED IN APPROVED MANNER W/APPROVED MATERIAL,FIXTURES USING LIGHT CHAI
#35122673H
Feb 9, 2015
STIPULATION/IN-VIO
$0
Dec 23, 2014Unknown CLASS - 2
FAILURE TO PROVIDE/MAINTAIN SUFFICIENT ACCESS,WORK SPACE ABOUT ELECTRICAL EQUIPMENT. OBSERVED AT 1:45PM THAT ACCESS TO MAIN SERVICE DISCONNECT SWITCH & CIRCUIT BREAKER PANEL,METER IS OBSTRUCTED BY STORAGE MIN 3
#35122674J
Feb 9, 2015
STIPULATION/IN-VIO
$0
Dec 23, 2014Unknown CLASS - 1
SEC. 400.8 MISC. VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS 1:45PM OBSERVED FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD FOR BRANCH CIRCUITS & POWER TO MOTORIZED GATE MOTORS FOR BRANCH CIRCUITS AND
#35122670M
May 11, 2015
IN VIOLATION
$0
Dec 23, 2014Unknown CLASS - 1
ELECTRICAL WORK W/O PERMIT. ELECTRICAL WIRING INSIDE & OUTSIDE PRIOR TO OBTAINING PERMIT. BRACH CIRCUITS,FLUORESCENT FIXTURES,SWITCHES RECEPTICLE OUTLETS,MOTORS,CONTROL WIRING,OBSERVED SAID VIOLATIONS AT 1:45PM
#35122669P
May 4, 2015
IN VIOLATION
$0
Dec 23, 2014Unknown CLASS - 2
FAIL TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS,ENCLOSURES,CABLE ARMOR. OBSERVED AT 1:45PM THAT ARMORED CABLES ARE OPEN SPLICE BOX TO METERIZAL GATE MOTORS. GATES & MOTORS ARE NOT GROUNDED &
#35122672X
May 11, 2015
IN VIOLATION
$0
Dec 23, 2014Unknown CLASS - 1
UNAPPROVED/UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WIRING IN USE. AT 1:45PM OBSERVED OUTSIDE UNDER CANOPY INDOOR FIXTURES USED OUTDOORS. NOT APPROVED FOR (DAMPER)WET LOC
#35122671Y
May 11, 2015
IN VIOLATION