Manhattan · Block 189 · Lot 22 · 10013

42 North Moore Street

6 floors · 5 apartments · 12,200 sq ft · built 1891 · class D2 · owner of record: Moore Street Bldg Co

19open violations
$8,750ECB/OATH penalties owed
3HPD class C (immediately hazardous)
50dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 50 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 66 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 781 days
Next cycle year 2028

Open violations

ECB / OATH (5) · $8,750 owed
IssuedViolationHearingBalance
Aug 26, 2026Construction CLASS - 2
NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39155159L ISSUED 7/28/2025, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION,
#39202006J
Dec 17, 2026
PENDING
$1,250
Aug 24, 2026Construction CLASS - 1
AGGRAVATED CONDITIONS OBSERVED AT TODAY'S INSPECTION, CONSISTENT WITH VIOLATION #39088731X ISSUED 6/18/2023. ACCESS GAINED. AT EXPOSURE 1, OBSERVED SPALLING, CRACKING, AND DETERIORATION AT LIMESTONE LINTELS AND
#39201554X
Dec 17, 2026
PENDING
$6,250
Aug 24, 2026Construction CLASS - 2
NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39129341Z ISSUED 11/3/2024, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION,
#39201553Y
Dec 17, 2026
PENDING
$1,250
Jul 28, 2025Construction CLASS - 1
FAILURE TO COMPLY AND SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39129341Z ISSUED ON 11/3/2024 FOR WORK WITHOUT PERMIT FOR SIDE WALK SHED, COMPLY WITH COMMISSIONER'S ORDER
#39155159L
Apr 16, 2026
IN VIOLATION
$0
Nov 3, 2024Construction CLASS - 1
WORK WITHOUT A PERMIT: THE FRONT ELEVATION HAS A SIDEWALK SHED 20'X12'X12' ERECTED WITHOUT A PERMIT AT TIME OF INSPECTION, OBTAIN PERMIT
#39129341Z
Apr 16, 2026
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Oct 20, 1994CONSTRUCTION

#AMG01
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
HPD (11) · C 3 · B 5 · A 3
IssuedClassViolationCorrect by
Jan 22, 2025BApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 4TH WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 26, 2025
Jan 22, 2025CApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 1ST WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 28, 2025
Jan 22, 2025AApt 2 · § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK IN THE 2nd BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTApr 27, 2025
Jan 22, 2025CApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 2ND WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 28, 2025
Jan 22, 2025BApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 1ST WINDOW FROM NORTH IN THE 4th ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 26, 2025
Jan 22, 2025CApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER AT 2ND WINDOW FROM NORTH IN THE 4th ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 28, 2025
Jan 22, 2025BApt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 3RD WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 26, 2025
Jan 22, 2025BApt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL AND CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 26, 2025
Jan 21, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD THRESHOLD AT ENTRANCE TO BUILDING , 1st STORYFeb 25, 2025
Oct 7, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL AT PUBLIC HALL, 2nd STORYJan 10, 2025
Oct 7, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL AND CEILING AT PUBLIC HALL STAIRS, 6th STORYJan 10, 2025

Issued in the last 120 days

DateSourceWhatNow
Sep 30, 2026DOB SafetyAEUHAZ: Open
Aug 26, 2026ECBConstruction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39155159L ISSUED 7/28/2025, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION,Open
Aug 24, 2026ECBConstruction: AGGRAVATED CONDITIONS OBSERVED AT TODAY'S INSPECTION, CONSISTENT WITH VIOLATION #39088731X ISSUED 6/18/2023. ACCESS GAINED. AT EXPOSURE 1, OBSERVED SPALLING, CRACKING, AND DETERIORATION AT LIMESTONE LINTELS ANDOpen
Aug 24, 2026ECBConstruction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39129341Z ISSUED 11/3/2024, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION,Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 10:35 AM ET. BBL 1001890022.

Look up another building