6 floors · 5 apartments · 12,200 sq ft · built 1891 · class D2 · owner of record: Moore Street Bldg Co
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 50 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 66 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 781 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 26, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39155159L ISSUED 7/28/2025, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION, #39202006J | Dec 17, 2026 PENDING | $1,250 |
| Aug 24, 2026 | Construction CLASS - 1 AGGRAVATED CONDITIONS OBSERVED AT TODAY'S INSPECTION, CONSISTENT WITH VIOLATION #39088731X ISSUED 6/18/2023. ACCESS GAINED. AT EXPOSURE 1, OBSERVED SPALLING, CRACKING, AND DETERIORATION AT LIMESTONE LINTELS AND #39201554X | Dec 17, 2026 PENDING | $6,250 |
| Aug 24, 2026 | Construction CLASS - 2 NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39129341Z ISSUED 11/3/2024, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION, #39201553Y | Dec 17, 2026 PENDING | $1,250 |
| Jul 28, 2025 | Construction CLASS - 1 FAILURE TO COMPLY AND SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39129341Z ISSUED ON 11/3/2024 FOR WORK WITHOUT PERMIT FOR SIDE WALK SHED, COMPLY WITH COMMISSIONER'S ORDER #39155159L | Apr 16, 2026 IN VIOLATION | $0 |
| Nov 3, 2024 | Construction CLASS - 1 WORK WITHOUT A PERMIT: THE FRONT ELEVATION HAS A SIDEWALK SHED 20'X12'X12' ERECTED WITHOUT A PERMIT AT TIME OF INSPECTION, OBTAIN PERMIT #39129341Z | Apr 16, 2026 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 20, 1994 | CONSTRUCTION #AMG01 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 22, 2025 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 4TH WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 26, 2025 |
| Jan 22, 2025 | C | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 1ST WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 28, 2025 |
| Jan 22, 2025 | A | Apt 2 · § 27-2065 ADM CODE PROVIDE VENTILATION FOR WATER CLOSET COMPARTMENT AND/OR BATHROOM AND FILE APPLICATION FOR APPROVAL BEFORE DOING WORK IN THE 2nd BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 27, 2025 |
| Jan 22, 2025 | C | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 2ND WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 28, 2025 |
| Jan 22, 2025 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 1ST WINDOW FROM NORTH IN THE 4th ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 26, 2025 |
| Jan 22, 2025 | C | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER AT 2ND WINDOW FROM NORTH IN THE 4th ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 28, 2025 |
| Jan 22, 2025 | B | Apt 2 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE LOWER SASH AT 3RD WINDOW FROM WEST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 26, 2025 |
| Jan 22, 2025 | B | Apt 2 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL AND CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 26, 2025 |
| Jan 21, 2025 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD THRESHOLD AT ENTRANCE TO BUILDING , 1st STORY | Feb 25, 2025 |
| Oct 7, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL AT PUBLIC HALL, 2nd STORY | Jan 10, 2025 |
| Oct 7, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WEST WALL AND CEILING AT PUBLIC HALL STAIRS, 6th STORY | Jan 10, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 26, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39155159L ISSUED 7/28/2025, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION, | Open |
| Aug 24, 2026 | ECB | Construction: AGGRAVATED CONDITIONS OBSERVED AT TODAY'S INSPECTION, CONSISTENT WITH VIOLATION #39088731X ISSUED 6/18/2023. ACCESS GAINED. AT EXPOSURE 1, OBSERVED SPALLING, CRACKING, AND DETERIORATION AT LIMESTONE LINTELS AND | Open |
| Aug 24, 2026 | ECB | Construction: NO CERTIFICATE OF CORRECTION ON FILE FOR CLASS 1 WORK-WITHOUT-PERMIT VIOLATION #39129341Z ISSUED 11/3/2024, CITING A 20' X 12' X 12' SIDEWALK SHED ERECTED AT THE FRONT ELEVATION WITHOUT A PERMIT. AT INSPECTION, | Open |